Description
1. Commercial Introduction
The NYLON SUTURE PREMISUT Prime 4/0 black, 45 cm, with DS26 Prime needle is the reference solution within Cahnos’ premium range of non-absorbable sutures for procedures requiring fineness, clean passage and secure knotting. It combines an uncoated nylon (polyamide 6 or 6.6) monofilament, black and grooved for maximum visibility in the surgical field, with a 3/8 circle needle with a 26 mm reverse cutting triangular point. It is the usual choice for ophthalmology, neurosurgery, skin surgery departments and procurement centres seeking full traceability and predictable clinical performance. Sterile, ready-to-use product, presented in a box of 12 individual pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the sawing effect, minimises bacterial adherence compared with multifilament sutures and promotes a firm, stable knot.
The 3/8 circle needle with a reverse cutting triangular point (reverse cutting) concentrates the cutting edge on the convex side of the arc and cuts away from the wound, preventing tearing of the skin edge. The grooved body of the DS26 Prime needle improves needle holder grip and torque transmission, providing a clean entry hole and a quality cosmetic result. The USP 4/0 gauge (metric EP 1.5) offers the fineness required for delicate tissues with sufficient strength for safe healing, and the 45 cm thread is ideal for ophthalmology, neurosurgery and precision sutures.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon (polyamide 6 or 6.6), uncoated monofilament |
| Structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, retains tensile strength for more than 3 months |
| Gauge | USP 4/0 (metric EP 1.5), in accordance with USP gauges and the European Pharmacopoeia |
| Thread length | 45 cm |
| Colour | Black (high visibility in surgical field) |
| Needle shape | 3/8 circle (3/8 circular) |
| Tip type | Reverse cutting triangular (reverse cutting) |
| Needle size | DS26 Prime (26 mm) |
| Swaged | 1 strand of 45 cm with 3/8 triangular reverse cutting needle |
| Sterilisation | Ethylene oxide (EtO), sterile; single use, do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery and skin surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Reference Cahnos (SKU) | AMP641DS2640 |
Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture):
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
4. Equivalences and Cross-References
The Cahnos reference AMP641DS2640 corresponds to the Premisut Prime range: DS26 Prime reverse cutting needle, 26 mm, USP 4/0 gauge, black grooved thread, 45 cm. There is no equivalence table validated by the manufacturer that cross-references this code with other brands; consult the technical department before using it in tenders or substitution. The following comparisons are functional, at category level, and have been checked against official catalogues and authorised distribution; they must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHILON™ – black nylon monofilament, 4-0, 45 cm, FS-2 needle of 19 mm, 3/8 circle, reverse cutting | 662G | Comparable by category (not interchangeable 1:1) | Code confirmed in Ethicon’s official catalogue and authorised distribution. It matches in material (polyamide), gauge 4/0, black colour, length 45 cm and 3/8 reverse cutting geometry; the needle differs (FS-2, 19 mm, versus DS26 Prime, 26 mm). Verify IFU before substituting. |
| Ethicon (Johnson & Johnson MedTech) | ETHILON™ – black nylon monofilament, 4-0, 45 cm, PS-2S PRIME needle of 19 mm, 3/8 circle, reverse cutting Prime | 1667SLH | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution. Same material, gauge, colour and length, with Prime reverse cutting point, but 19 mm needle (PS-2S PRIME) versus DS26 Prime, 26 mm. Confirm commercial presentation before substituting. |
| B. Braun | DAFILON® – polyamide monofilament, 4/0 (EP 1.5), reverse cutting (RC) needle, 3/8 circle, 19 mm | C0935204 | Comparable by category (not interchangeable 1:1) | Code confirmed in B. Braun’s official catalogue and authorised distribution. Same material (polyamide) and gauge 4/0 with 3/8 reverse cutting needle; the colour (blue in the standard version versus black), needle size (19 mm versus 26 mm) and presentation (box of 36 units) differ. The black variant of Dafilon (polyamide 6.6) is used in ophthalmology and microsurgery; confirm the black colour code with the manufacturer. |
There is no equivalence table validated by the manufacturer for this configuration; check the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) in the technical data sheet or IFU of the alternative manufacturer before using this information in tenders or direct substitution. Consult Cahnos’s technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the USP 4/0 gauge (EP 1.5) is ideal for fine skin, mucous membranes, subcutaneous tissue, ophthalmology, neurosurgery and precision ligatures. The DS26 Prime reverse cutting needle penetrates firm, non-distensible tissues without tearing the puncture bed; for vascular or lax planes, consider round point profiles from the same range.
Thread length: this reference is 45 cm, suitable for precision procedures and interrupted sutures. If the protocol requires more length, the same DS26 Prime needle is available with 75 cm thread and in double format 2 x 75 cm.
Portfolio unification: the same DS26 Prime needle is offered in USP 2/0, 3/0 and 4/0 to unify supplier across the entire range of non-absorbable sutures. Below are the available variants of the family:
| Needle profile | USP size | Thread | SKU Cahnos |
| DS26 Prime | 4/0 | 1 x 45 cm (black) | AMP641DS2640 (this product) |
| DS26 Prime | 3/0 | 1 x 75 cm (black) | AMP641DS2630 |
| DS26 Prime | 3/0 | 1 x 45 cm (black) | AMP642DS2630 |
| DS26 Prime | 3/0 | 2 x 75 cm (black) | AMP642DS2630.2 |
| DS26 Prime | 2/0 | 1 x 45 cm (black) | AMP641DS2620 |
| DS26 Prime | 2/0 | 2 x 75 cm (black) | AMP642DS2620.2 |
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference AMP641DS2640 together with the batch number for traceability in the operating theatre. For B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact Cahnos’s technical-commercial team.





Reviews