Description
1. Commercial Introduction
The Nylon suture PREMISUT Prime USP 2/0 is the reference solution within the premium range of non-absorbable sutures from Cahnos for procedures on soft tissues that require reliability, clean passage and secure knotting. It combines an uncoated nylon monofilament (polyamide 6 or 6.6), black and grooved for maximum visibility in the surgical field, with a 3/8 circle triangular reverse cutting needle of 26 mm (DS26 Prime profile). It is the usual choice of ophthalmology, neurosurgery, skin surgery departments and purchasing centres that seek complete traceability and predictable clinical behaviour. Sterile product, ready to use, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it is gradually encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the sawing effect, minimises bacterial adherence compared to multifilaments and promotes a firm, stable knot; its grooved finish provides an extra point of safety in the approximation of soft tissues, minimising the risk of accidental loosening.
The 3/8 circle needle with a triangular reverse cutting point concentrates the cutting edge on the convex side of the arc and cuts outward from the wound, avoiding tearing of the skin edge; the grooved body of the DS26 Prime needle improves the grip of the needle holder and the transmission of rotation. This geometry is intended for skin, mucous membranes and firm tissues of medium consistency, with a clean entry hole and a quality cosmetic result.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon (polyamide 6 or 6.6), uncoated monofilament |
| Structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, retains tensile strength for more than 3 months |
| Gauge | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm |
| Colour | Black (high visibility in surgical field) |
| Needle shape | 3/8 circle (3/8 circular) |
| Tip type | Triangular reverse cutting (reverse cutting), DS Prime profile |
| Needle size | DS26 Prime (26 mm) |
| Swaged | 1 thread of 75 cm with 3/8 triangular reverse cutting needle |
| Sterilisation | Ethylene oxide (EtO), sterile; single use, do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery and skin surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P642DS2620 |
| Reference Cahnos (SKU) | AMP642DS2620 |
Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture):
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
4. Equivalences and Cross-References
The reference P642DS2620 corresponds to the official nomenclature of the Premisut Prime range: DS26 Prime reverse cutting needle of 26 mm, USP 2/0 gauge, black grooved thread of 75 cm. Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tendering or substitution. The following comparisons are functional, at category level, and have been checked against official catalogues and authorised distribution; they must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | ETHILON™ – black nylon monofilament, 2/0, 75 cm, PS Prime needle of 26 mm, 3/8 circle, reverse cutting | W1626BH | Comparable by category (not interchangeable 1:1) | Code confirmed in the official Ethicon EMEA catalogue and authorised distribution. It matches in material (polyamide), gauge 2/0, black colour, thread length (75 cm), 3/8 circle radius and Prime needle of 26 mm; it differs in needle profile (PS Prime vs DS) and presentation (box of 36 units vs 12 units). Verify IFU before substituting. |
| Medtronic (Covidien) | MONOSOF™ – black nylon monofilament, 2/0, 75 cm (30″), C-15 needle of 26 mm, 3/8 circle, reverse cutting | SN-664 | Comparable by category (not interchangeable 1:1) | Code confirmed in the Medtronic catalogue and authorised distribution. Same non-absorbable material (nylon 6), gauge 2/0, black colour, needle size (26 mm) and length (75 cm); it differs in needle profile (C-15 vs DS Prime) and presentation (box of 36 units). Confirm data sheet before substituting. |
| B. Braun | DAFILON® – blue polyamide monofilament, 2/0 (EP 3), 75 cm, DS24 needle of 3/8 circle, reverse cutting | C0935360 | Comparable by category (not interchangeable 1:1) | Code confirmed in the official B. Braun catalogue and authorised distribution. Same material (polyamide), gauge 2/0 (EP 3) and length 75 cm; they differ in colour (blue vs black), needle (DS24 of 24 mm vs DS26 of 26 mm) and presentation. The black variant of Dafilon (polyamide 6.6) is used in microsurgery and ophthalmology; confirm the code of the black version with the manufacturer. |
There is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the DS26 Prime reverse cutting needle is suitable for skin, mucous membranes and firm tissues of medium consistency, as well as for approximation of soft tissues and ligatures. For vascular or lax planes, consider round point profiles from the same range.
Gauge: USP 2/0 (EP 3) offers an optimal balance between strength and manageability for skin, subcutaneous tissue and medium-tension ligatures; for finer planes consider 3/0 or 4/0 from the same family, and for fascia or higher loads, larger gauges.
Length and format: this reference provides 1 thread of 75 cm. If the protocol requires more length or higher performance, the same DS26 Prime needle is available in double format 2 x 75 cm; if a shorter thread is preferred for precision sutures, a 45 cm version is available.
| Needle profile | USP size | Thread | SKU Cahnos |
|---|---|---|---|
| DS26 Prime | 2/0 | 1 x 75 cm (black) | AMP642DS2620 (this product) |
| DS26 Prime | 2/0 | 2 x 75 cm (black) | AMP642DS2620.2 |
| DS26 Prime | 2/0 | 1 x 45 cm (black) | AMP641DS2620 |
| DS26 Prime | 3/0 | 1 x 75 cm (black) | AMP642DS2630 |
| DS24 Prime | 2/0 | 1 x 75 cm (black) | AMP642DS2420 |
| DS26 standard (not Prime) | 2/0 | 1 x 75 cm (black) | AM642DS2620 |
Sterility verification: product sterilised by ethylene oxide and for single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642DS2620 together with the batch number for traceability in the operating theatre. For volume B2B terms, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.