Description
1. Product Presentation
We are pleased to offer the nylon monofilament suture from the PREMISUT range, reference AM647DS6020 (manufacturer reference 647DS6020), a professional solution for B2B supply to operating theatres, central purchasing departments, general and specialist surgery services, as well as ophthalmology and neurosurgery units.
This presentation incorporates a 3/8 circle reverse cutting needle of 60 mm (DS60) with black thread of 100 cm in gauge USP 2/0, one of the most demanded configurations for precision suture on soft tissues, ligatures and deep access planes. Predictable behaviour, high tensile strength and special conditions for hospital supply, tenders and volume contracts.
2. Technical explanation of the material and procedure
The suture is manufactured in nylon (polyamide 6 or 6.6) in a monofilament configuration: a single continuous, smooth and uncoated filament, which minimises microorganism adherence, the sawing effect on tissue and the inflammatory reaction. Being non-absorbable, it permanently maintains its structural integrity and provides gradual encapsulation with great tensile strength, helping to support the wound for more than three months and amply covering the critical healing phase. The grooved finish of the thread improves grip during knotting.
The 3/8 circle needle with triangular body and reverse cutting point of 60 mm allows precise and minimally traumatic penetration in tissues with some resistance: the edge cuts in the opposite direction to the puncture bed, which preserves the skin edge and prevents the cut from widening. It is ideal for sutures in closed planes, dermis, subcutaneous tissue and precision approximations in ophthalmology and neurosurgery. The black colour guarantees optimal contrast on the surgical field. Ethylene oxide sterilisation ensures its sterile delivery, ready for immediate use; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AM647DS6020 |
| Factory reference | 647DS6020 |
| Brand / Quality | PREMISUT – standard quality |
| Material | Nylon (polyamide 6 / 6.6), synthetic monofilament |
| Thread structure | Monofilament, uncoated, grooved finish |
| Gauge / USP size | USP 2/0 (metric 3 / EP 3) |
| Approximate thread diameter | 0.30 – 0.339 mm (non-absorbable suture, according to USP Pharmacopoeia) |
| Thread length | 100 cm |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular), grooved |
| Tip type | Reverse cutting triangular (Reverse Cutting), triangular body and point |
| Needle size | 60 mm (model DS 60), grooved |
| Swaged | 1 needle per suture |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Regulatory classification | Medical device; verify current CE/MDR class of the batch |
Gauge equivalence (non-absorbable suture, according to USP Pharmacopeia):
| USP size | Metric measurement (EP) | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
Minimal tissue reaction, excellent tensile strength, secure knot and totally predictable behaviour as there is no polymer degradation in the body. The thread diameter complies with the USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its official limits.
4. Equivalences and Cross-References
Non-absorbable nylon monofilament is one of the most widespread permanent suture families in the surgical market for soft tissue approximation and ligatures. There is no equivalence table validated by the manufacturer that cross-references this specific configuration (3/8 circle reverse cutting needle DS60 mm, USP gauge 2/0, black, 100 cm) with references from other brands; therefore, coincidences must be treated as functional comparisons and not as 1:1 interchangeable without technical validation. The cited reference has been verified against the manufacturer’s official source or its public catalogue.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Dafilon® – uncoated polyamide monofilament | B0935905 (USP 2/0, blue, 100 cm, DS60 needle) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official catalogue of B. Braun and GUDID records (B. Braun Surgical, Dafilon). It matches in material (polyamide 6/6.6), USP gauge 2/0 (EP 3), thread length of 100 cm, 3/8 circle curvature, reverse cutting point family and DS60 needle size of 60 mm; the thread colour differs: blue in this reference versus black in the Cahnos suture. The black version of Dafilon (polyamide 6.6) is marketed for ophthalmology and microsurgery, but its code with this same configuration has not been verified in public sources; confirm with the manufacturer. |
Other homologous families of non-absorbable nylon monofilament to verify in their technical data sheets and official sources (GUDID/EUDAMED or manufacturer catalogue) before any substitution: Ethicon (Johnson \u0026 Johnson) – ETHILON (polyamide 6/6.6 monofilament, black dye, 3/8 circle cutting needles in PS/FS series of 13–24 mm; no public code verified with DS60 needle of 60 mm in this configuration), Medtronic – Dermalon / Monosof (black nylon, GUDID/FDA records; verify needle nomenclature) and UNIFY / AD Surgical (ref. XXL-N230K60, black nylon 2/0 75 cm with straight KS needle of 60 mm, differs in curvature and thread length, therefore not included in the table).
Closing phrase: There is no equivalence table validated by the manufacturer for this configuration (DS60 mm needle, USP 2/0, black, 100 cm); consult the technical-commercial department of Cahnos before use in a tender. Before any formal substitution, verify in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). This needle geometry (DS60, USP 2/0, 100 cm) is only fully safely interchangeable within the PREMISUT system itself. The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Assess the wound support time required by the tissue and the gauge according to the anatomical area: USP 2/0 (metric 3) is very versatile, indicated for skin, subcutaneous tissue and soft tissues with moderate tension, as well as for precise approximation in ophthalmology and neurosurgery. Always check the needle geometry: the DS series of 3/8 circle with reverse cutting is intended for deep sutures, closed planes and tissues with some resistance, as opposed to straight needles (GS) with conventional cutting for direct access.
Variants of interest within the Cahnos catalogue:
- AMP647DS6020: nylon Premisut Prime, same configuration DS60 mm, USP 2/0, black, 100 cm (Prime quality with improved surface; direct equivalent within the range).
- AM642DS6020 / AMP642DS6020: standard and Prime nylon, DS60 mm needle, USP 2/0, black, 75 cm (same needle, shorter thread).
- AMP647RDS6020: nylon Premisut Prime, DS60 mm needle, USP 2/0, black, presentation 2 × 100 cm.
- AM642DS6010 / AMP642DS6010: DS60 mm needle, USP 0, black, 75 cm (larger gauge for tissues with more tension).
- AM642GS6020: nylon with straight GS 60 mm needle with conventional cutting, for direct access suturing.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.