Description
1. Commercial Introduction
The NYLON Suture PREMISUT 3/8 Triangular DS50 USP 1 Black 90 cm (Ref. 643DS5001 · SKU AM643DS5001) is the reference in the standard range of non-absorbable sutures from Cahnos for procedures requiring a permanent thread of medium-long length and a medium-bodied reverse cutting needle. This configuration combines a nylon monofilament (polyamide 6 or 6.6), identifying black colour, USP 1 gauge and 90 cm of grooved thread, mounted on a ⅜ circle needle with a 50 mm reverse cutting triangular point (DS50 profile).
It is a common choice in general surgery, ophthalmology, neurosurgery departments and in purchasing and tendering centres that need a high-performance permanent thread with predictable clinical behaviour and full traceability. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention and handling.
The 50 mm DS50 needle features a ⅜ circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed, facilitating passage through firm, non-distensible tissues. Its intermediate length makes it especially suitable for medium-depth access, skin closure and subcutaneous tissue in standard surgical fields. The USP 1 gauge (metric EP 4) provides high tensile strength for tissues under medium-high tension, and the 90 cm of thread offers sufficient length for continuous sutures or multiple stitches without re-threading. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT (standard line) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | DS 50 (50 mm) |
| Configuration | 1 needle per unit, grooved thread |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 643DS5001 |
| Reference Cahnos (SKU) | AM643DS5001 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT DS50 family (⅜ circle needle, 50 mm, reverse cutting triangular point)
| Needle profile | USP size | Thread | Reference |
| DS50 | 1 | 1 × 90 cm (black) | 643DS5001 / AM643DS5001 (this product) |
| DS50 | 0 | 1 × 90 cm (black) | 643DS5010 / AM643DS5010 |
| DS50 Prime | 1 | 1 × 90 cm (black, Prime range) | AMP643DS5001 |
| DS50 Prime | 1 | 2 × 90 cm (black, Prime range) | AMP643DS5001.2 |
| DS50 Prime | 0 | 1 × 90 cm (black, Prime range) | AMP643DS5010 |
4. Equivalences and Cross-References
Reference 643DS5001 corresponds to the official nomenclature of the PREMISUT range (DS50 profile: ⅜ circle needle with 50 mm reverse cutting triangular point, USP 1 gauge, black 90 cm grooved thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially of the ‘Ethilon’ type).
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Medtronic (Covidien) | Monosof™ (black nylon monofilament) | SN-776 | Comparable by category (not interchangeable 1:1) | They match in material (nylon 6/6.6), USP 1 gauge, black colour, 90 cm thread (36″) and ⅜ circle reverse cutting needle; however, the C-17 needle measures 39 mm, 11 mm shorter than the 50 mm DS50, and the box contains 36 units. Verified in GUDID and Medtronic data sheet. |
| Ethicon (J&J MedTech) | ETHILON™ / ETHILON II™ (black nylon monofilament) | F2440H | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge (EP 4), black colour and thread length (90 cm); the FSL needle is ⅜ circle with reverse cutting but 30 mm, considerably shorter than the DS50. Verified in the Ethicon EMEA catalogue. |
| B. Braun (Aesculap) | Dafilon® (polyamide monofilament) | C0934925 / G0934925 | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 1 gauge (EP 4) and DS reverse cutting needle family; the colour is blue and the needle is a 90 mm DS90 with 100 cm thread, compared with the black 90 cm strand with DS50 of this reference. Verified in official B. Braun catalogues. |
Additional homologous families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON (black nylon monofilament), B. Braun DAFILON, SMI SUPRAMID, LuxSutures Luxamid and DemeTECH DemeLON.
Mandatory closing statement: there is no manufacturer-validated equivalence table for this configuration; check the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) in the technical data sheet or IFU of the alternative manufacturer before using this information in tenders or direct substitution. This needle geometry (DS50, USP 1, 90 cm) is only safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 1 gauge (EP 4) offers high tensile strength for subcutaneous tissue, fasciae, aponeuroses and soft tissues under medium-high tension. For finer planes, consider USP 0 or 2/0 from the same family; the reverse cutting needle passes through firm tissues without tearing the puncture bed and improves the aesthetic result compared with a cylindrical needle.
- Needle length: the DS50 profile of 50 mm covers medium-depth access. For smaller fields, the DS24–DS45 families (24–45 mm) of the same nylon range are available (e.g. the DS40 USP 1 variant, Ref. 643DS4001 / AM643DS4001); if more reach is needed, the same reverse-cutting needle is available in DS90 (Ref. 643DS9001 / AM643DS9001).
- Thread length and presentation: this reference is 1 × 90 cm (series 643). The 2 × 90 cm version in Prime quality (AMP643DS5001.2) reduces waste in surgeries requiring multiple stitches, and the same DS50 needle is offered with 75 cm thread (series 642) for shorter procedures.
- Portfolio unification: the same DS50 needle is available in USP 0 (AM643DS5010) and in Prime quality (AMP643DS5001) to unify the supplier across the entire range of non-absorbable sutures with a medium needle.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference 643DS5001 and the batch number for traceability in the operating theatre.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.