Description
1. Commercial Introduction
The NYLON Suture PREMISUT 3/8 Triangular DS19mm 2/0 Black 75cm is the reference solution for operating theatres, purchasing departments and tenders seeking a non-absorbable suture with predictable performance and excellent value for money. It combines an uncoated nylon monofilament (polyamide 6 or 6.6) in black for high visibility in the surgical field, with a ⅜-circle needle with a reverse cutting triangular point of 19 mm (DS19 profile) and USP 2/0 gauge: the ideal format for approximating soft tissues, ligatures and precision specialties such as ophthalmology and neurosurgery. It is supplied sterile, ready for single use, in a box of 12 units with batch traceability.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the strand slides easily through tissues, reducing the sawing effect, bacterial adherence and inflammatory reaction compared with multifilaments; the grooved finish improves knot retention and facilitates handling.
The DS19 needle of 19 mm features a ⅜-circle curvature with a reverse cutting triangular body and point (reverse cutting): the cutting edge cuts in the opposite direction to the puncture bed, preserving the skin edge and preventing the cut from widening, facilitating passage through firm, poorly distensible tissues (dermis, subcutaneous tissue and precision approximations). The USP 2/0 gauge (metric EP 3) provides an excellent balance between fineness and strength for approximating soft tissues and performing secure ligatures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
| Factory reference | 642DS1920 |
| Reference Cahnos (SKU) | AM642DS1920 |
| Brand / quality | PREMISUT – standard quality |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament with grooved surface (grooved black) |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Indicative thread diameter | 0.30 – 0.34 mm |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Black |
| Needle shape | ⅜ circle (3/8 circular), fluted |
| Needle type | Triangular reverse cutting point (reverse cutting), triangular body and point |
| Needle size | 19 mm (DS 19 profile) |
| Configuration / assembly | 1 needle per unit |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
3.2. PREMISUT DS 19 family in nylon (⅜ circle, reverse cutting triangular point)
| Needle profile | USP size | Presentation | Reference |
| DS 19 | 2/0 | 1 × 75 cm | 642DS1920 / AM642DS1920 (this product) |
| DS 19 | 3/0 | 1 × 75 cm | 642DS1930 / AM642DS1930 |
| DS 19 | 4/0 | 1 × 75 cm | 642DS1940 / AM642DS1940 |
| DS 19 | 5/0 | 1 × 75 cm | 642DS1950 / AM642DS1950 |
| DS 19 Prime | 2/0 | 1 × 75 cm | P642DS1920 / AMP642DS1920 (direct equivalent in the Prime range) |
3.3. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | EP metric measure | Indicative diameter |
| 5/0 | 1 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.34 mm |
4. Equivalences and Cross-References
Reference 642DS1920 corresponds to the official nomenclature of the PREMISUT range (DS 19 needle of ⅜ circle, reverse cutting triangular point of 19 mm, USP 2/0 gauge, black grooved thread of 75 cm) and Cahnos markets it without altering any characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following matches are functional comparisons verified against the official catalogue or authorised distribution and must not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – non-absorbable nylon monofilament, USP 2/0, 75 cm, KS needle with reverse cutting triangular point, 19 mm (⅜ circle) | 628H (verified in official Ethicon EPC catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide/nylon 6 and 6.6), gauge 2/0, black colour, length of 75 cm, ⅜ radius and reverse cutting point family; the KS needle shows divergent descriptions between sources (⅜ circle 19 mm versus straight needle of 60 mm according to distributor) and the commercial presentation is a box of 36 units; confirm needle geometry and IFU before substituting. |
| B. Braun (Aesculap) | DAFILON® blue – uncoated polyamide 6/6.6 monofilament, USP 2/0 (EP 3), 75 cm, DS19 needle of ⅜ circle reverse cutting triangular point of 19 mm | C0935213 (verified in official B. Braun catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), USP 2/0 gauge (EP 3), length of 75 cm, ⅜ radius and DS19 needle of 19 mm; the thread colour differs (blue versus black). The black Dafilon® variant is intended for microsurgery and ophthalmology; confirm its specific code with the manufacturer. Validate IFU and CE/MDR classification before substituting. |
There is no manufacturer-validated equivalence table cross-referencing reference 642DS1920 with other brands; the comparisons with ETHILON® and DAFILON® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Other homologous families on the market (for example, DemeLON from DemeTECH or MONOSOF from Medtronic/Covidien, nylon monofilament) require code-by-code verification of gauge, length, colour and needle geometry; DS 19 geometry is only fully safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the DS needle with reverse cutting triangular point is indicated for skin, mucosa and fibrous planes that require firm penetration with minimal trauma; for lax, vascular or well-irrigated soft tissues, the same PREMISUT range offers conical point needles (HR profiles). The USP 2/0 gauge is an ideal balance point between fineness and strength for soft tissues and ligatures.
Gauge and presentation: with the same DS 19 needle you will find nylon in gauges 3/0 (AM642DS1930), 4/0 (AM642DS1940) and 5/0 (AM642DS1950), all in 75 cm, allowing you to unify supplier across the entire non-absorbable nylon range. If you prefer an improved needle finish, the same configuration is available in Prime quality (SKU AMP642DS1920, direct equivalent within the same manufacturer); for continuous or multi-point sutures, the double-thread version of 2 × 75 cm (AMP642DS1920.2).
Specialties: in ophthalmology and microsurgery the range offers shorter and finer needle profiles in gauges 9/0 to 11/0 (DSP and HSP needles from the PREMISUT Prime system); for skin and cosmetic surgery, the XDS precision family with square body is the most requested.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 642DS1920 and the batch number for traceability in the operating theatre and in case of complaint. Store below 30 °C, away from humidity and direct sunlight. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.