Description
1. Commercial Introduction
At Cahnos we offer you the non-absorbable nylon monofilament suture from the PREMISUT Prime range, factory reference P642DS3520.2 (SKU AMP642DS3520.2), in a double-thread presentation (2 × 75 cm per pack). It is a professional solution for B2B supply to operating theatres, purchasing centres, general and specialist surgery departments, as well as ophthalmology and neurosurgery units.
This presentation incorporates a ⅜ circle reverse cutting needle of 35 mm (DS35 profile) with two black strands of 75 cm in USP 2/0 gauge, one of the most demanded configurations for precision suturing on soft tissues, ligatures and access planes. The Prime quality provides an improved surface finish that optimises passage through tissue and knot security, with predictable behaviour and high tensile strength. Sold by box of 12 units, with special conditions for hospital supply and volume contracts.
2. Technical Explanation
The thread is made of nylon (polyamide 6 or 6.6) in a monofilament configuration: a single continuous, smooth and uncoated filament that minimises microorganism adherence, the sawing effect on tissue and inflammatory reaction. The grooved finish of the strand improves knot grip. Being non-absorbable, it maintains its structural integrity permanently and provides gradual encapsulation with great tensile strength, helping to hold the wound for more than three months and comfortably covering the critical healing phase.
The DS35 needle of 35 mm features a ⅜ circle curvature with a reverse cutting triangular point (inverted triangle): the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed, facilitating passage through firm and poorly distensible tissues (dermis, subcutaneous tissue, closed planes and precision approximations). The black colour ensures optimal contrast on the surgical field. The double-thread presentation reduces waste in procedures requiring several stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 / 6.6), uncoated |
| Thread structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2/0 (metric 3 / EP 3), conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 2 × 75 cm (two strands per pack, 1 needle per strand) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8), grooved |
| Tip type | Reverse cutting triangular (triangular body and point) |
| Needle size | 35 mm (model DS 35 Prime) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units |
| Factory reference | P642DS3520.2 (in official price list: P642RDS3520.2; confirm nomenclature when tendering) |
| Reference Cahnos (SKU) | AMP642DS3520.2 |
3.2. Gauge equivalence (non-absorbable suture, USP/EP Pharmacopoeia)
| USP size | Metric measurement (EP) | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. DS35 Prime family (⅜ circle needle of 35 mm, reverse cutting)
| Needle profile | USP size | Thread | Reference |
| DS35 Prime | 3/0 | 1 × 75 cm (black) | P642DS3530 / AMP642DS3530 |
| DS35 Prime | 2/0 | 1 × 75 cm (black) | P642DS3520 / AMP642DS3520 |
| DS35 Prime | 2/0 | 2 × 75 cm (black) | P642DS3520.2 / AMP642DS3520.2 (this product) |
| DS35 Prime | 0 | 1 × 75 cm (black) | P642DS3510 / AMP642DS3510 |
| DS35 Prime | 0 | 2 × 75 cm (black) | P642DS3510.2 / AMP642DS3510.2 |
4. Equivalences and Cross-References
Non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market for soft tissue approximation and ligatures. There is no equivalence table validated by the manufacturer that cross-references this specific configuration (⅜ circle reverse cutting needle DS35 mm, USP 2/0 gauge, black, double thread 2×75 cm) with references from other houses; therefore, the following matches are functional comparisons and should not be treated as 1:1 interchangeable without prior technical validation and confirmation of the thread presentation. The codes cited have been checked against the manufacturer’s official catalogue or its authorised distribution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON, polyamide 6/6.6 monofilament | 1674BH (USP 2/0, black, 75 cm, FSLX 36 mm needle, ⅜ circle, reverse cutting) | Comparable by category (not interchangeable 1:1) | Code consistently confirmed in authorised distribution catalogues and J&J MedTech sources. Material, USP 2/0 gauge, black colour, thread length (75 cm) and ⅜ curvature with reverse cutting point match; the FSLX 36 mm needle is within the tolerance limit (±1 mm) but its designation and geometry are not directly equivalent to the DS35, and the presentation is single thread versus 2×75 cm. |
| B. Braun (Aesculap) | DAFILON, polyamide monofilament | C0935360 (USP 2/0, blue, 75 cm, DS24 needle, ⅜ circle, reverse cutting) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official B. Braun catalogue. Same material (polyamide 6/6.6), same USP 2/0 gauge (EP 3) and same thread length (75 cm); the strand colour (blue versus black), needle size (24 mm versus 35 mm, out of tolerance) and presentation (single thread versus double thread) differ. |
| DemeTECH (Degasa) | DemeLON, nylon monofilament | 1220730 (USP 2/0, black, 75 cm, 26 mm reverse cutting needle, ⅜ circle) | Comparable by category (not interchangeable 1:1) | Configuration confirmed in the official Degasa (DemeLON) catalogue. Identical thread vector (black nylon monofilament, USP 2/0, 75 cm) and same ⅜ circle curvature with reverse cutting point; the needle is 26 mm versus the DS35 of 35 mm (out of tolerance). Verify presentation and regulatory classification with the authorised distributor. |
Other homologous families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: Medtronic (Covidien) Monosof™, Serag-Wiessner Seralon, SMI SUPRAMID and LuxSutures Luxamid. No reference from these houses has been included in the table because no code has been confirmed with the combination USP 2/0 + ⅜ reverse cutting needle + black 75 cm thread + double-thread presentation.
There is no equivalence table validated by the manufacturer for this configuration (DS35 mm needle, USP 2/0, black, 2×75 cm); consult the technical-commercial department of Cahnos before use in tenders. Before any formal substitution, check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length and number of threads per package, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). This needle geometry (DS35, USP 2/0) can only be safely interchanged within the Premisut system itself.
5. Selection tips and variants of interest
Gauge according to anatomical area: USP 2/0 (EP 3) is very versatile, indicated for skin, subcutaneous tissue and soft tissues with moderate tension, as well as for precise approximation in ophthalmology and neurosurgery. For finer planes, consider the 3/0 gauges from the same DS35 family; for high tension, USP 0.
Double-thread presentation: the 2×75 cm version (P642DS3520.2) reduces waste in procedures requiring several stitches without re-threading; if the protocol requires a single thread, the 1×75 cm version (AMP642DS3520) is available.
Variants of interest within the Cahnos catalogue: AMP642DS3520 (DS35 Prime, USP 2/0, black, 1×75 cm); AMP642DS3530.2 (DS35 Prime, USP 3/0, black, 2×75 cm); AMP642DS3510.2 (DS35 Prime, USP 0, black, 2×75 cm); AMP642DS3020.2 (DS30 Prime, USP 2/0, black, 2×75 cm); and AMP643DS4520 (DS45 Prime, USP 2/0, black, 90 cm) for longer access routes. Consult these variants in the NYLON POLYAMIDE and NON-ABSORBABLE SUTURES categories.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure and keep the reference P642DS3520.2 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.