Description
1. Commercial Introduction
The NYLON SUTURE PREMISUT Prime with a ⅜ circular needle with a reverse cutting triangular point, 90 mm (DS90) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures that require a permanent, manageable thread with predictable clinical behaviour, mounted on a long-reach needle. It combines a monofilament of polyamide 6 or 6.6, dyed black, USP gauge 1 (metric EP 4) and an uncoated fluted strand of 90 cm, assembled on a DS90 Prime needle of 90 mm. It is a common choice in ophthalmology, neurosurgery, general surgery departments and purchasing and tendering centres that value batch-to-batch consistency and full traceability of the Prime range. Sterile, ready-to-use product, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by connective tissue and maintains high tensile strength for more than three months, comfortably covering the critical phase of wound healing. Being an uncoated monofilament, the thread reduces the wicking effect and bacterial adherence compared with multifilaments and minimises the inflammatory reaction; the fluted finish of the strand improves knot retention and handling, and the black colour ensures optimal contrast on the surgical field.
The DS90 Prime needle of 90 mm features a ⅜ circle curvature with a triangular point of reverse cutting: the cutting edge is located on the outside of the curvature, allowing it to penetrate skin, mucosa and dense fibrous tissues with a clean and controlled path, reducing trauma and facilitating thread sliding. Prime quality provides more consistent sharpening and more predictable penetration at each point. USP gauge 1 (metric EP 4) offers high tensile strength for soft tissue approximation and ligatures in tension planes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use from the manufacturer/distributor.
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P643DS9001 |
| Reference Cahnos (SKU) | AMP643DS9001 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Grooved monofilament (grooved black) |
| Absorption | Non-absorbable; gradual encapsulation, support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 90 cm (single strand, no loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8 circle) |
| Tip type | Triangular reverse cutting (reverse cutting) |
| Needle size | 90 mm (DS90 Prime profile) |
| Configuration | 1 needle × 90 cm per package (single armed) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Soft tissue approximation, ligatures, skin closure, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The thread diameter complies with the official ranges of the USP Pharmacopoeia for non-absorbable sutures, without extending its established limits.
3.3. PREMISUT DS90 family in nylon (⅜ circle needle, reverse cutting triangular point, black thread 90 cm)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| DS90 Prime | 3/0 | 1 × 90 cm (black) | P643DS9030 / AMP643DS9030 |
| DS90 Prime | 2/0 | 1 × 90 cm (black) | AMP643DS9020 |
| DS90 Prime | 0 | 1 × 90 cm (black) | AMP643DS9010 |
| DS90 Prime | 1 | 1 × 90 cm (black) | P643DS9001 / AMP643DS9001 (this product) |
| DS90 Prime | 2 | 1 × 90 cm (black) | P643DS9002 / AMP643DS9002 |
| DS90 standard | 2 | 1 × 90 cm (black) | 643DS9002 / AM643DS9002 |
4. Equivalences and Cross-References
The reference P643DS9001 corresponds to the official nomenclature of the PREMISUT Prime range (DS90 profile: ⅜ circle needle with reverse cutting triangular point of 90 mm, USP gauge 1, black fluted thread of 90 cm) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table that cross-references the exact combination of USP 1 + DS90 90 mm reverse cutting needle + black 90 cm strand with references from other brands in public sources (GUDID/EUDAMED and official catalogues); comparisons between brands must be made property by property (material, gauge, curvature, point family, needle size, strand length, colour and CE/MDR classification) and are functional, at category level, not interchangeable 1:1.
References for ⅜ circle 90 mm needles in USP gauge 2 have been verified in public sources (e.g. Laboratorio Aragó, Ref. 20300/10-20300, and DemeTECH DemeLON, Ref. NL360290F0P), but not in USP gauge 1; they are not listed in the table because they do not meet the required gauge tolerance. There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (DS90 Prime, USP 1, black 90 cm strand) is only safely interchangeable within the PREMISUT system itself: the standard version with identical configuration (Ref. 643DS9001) constitutes the direct equivalent within the same manufacturer. Homologous nylon monofilament families on the market that must be reviewed property by property before any substitution: Ethicon ETHILON® (J&J MedTech), B. Braun Dafilon® (Aesculap), Medtronic Monosof™/Dermalon™ (Covidien), DemeTECH DemeLON™ and Serag-Wiessner SERALON®. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
- Tissue to suture: the DS needle with reverse cutting triangular point is indicated for skin, mucosa and fibrous planes that require firm penetration with minimal trauma. USP gauge 1 (EP 4) provides high tensile strength, ideal for soft tissue approximation and ligatures in tension planes.
- Needle travel: the DS90 profile of 90 mm covers long-reach accesses and wide fields; if the protocol requires a shorter needle, the same range offers DS profiles of shorter length in nylon Premisut.
- Sizes in the same DS90 family: available in nylon 3/0 (P643DS9030), 2/0 (AMP643DS9020), 0 (AMP643DS9010) and 2 (AMP643DS9002) in a 90 cm black strand, to unify the range and adjust the size to the tissue layer to be sutured.
- Prime vs. standard quality: the Prime range offers maximum sharpening precision and batch-to-batch consistency; the standard version with an identical configuration (Ref. 643DS9001, SKU AM643DS9001) maintains the same dimensional specifications with standard sharpening performance and is the cost-optimised alternative.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P643DS9001 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.