Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 3/0 black, 45 cm is the reference in the premium range of non-absorbable sutures from Cahnos for procedures requiring a permanent, high-performance thread with predictable clinical behaviour. It combines a smooth-surface polyamide monofilament with a 3/8 circle needle with reverse cutting triangular point, 26 mm (DS26 Prime profile), designed for clean passage and firm knotting in skin, mucous membranes and soft tissues.
It is the usual choice in general surgery, ophthalmology, neurosurgery and skin surgery departments, as well as for purchasing centres that need full traceability, stable supply and B2B volume conditions. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Factory ref. P642DS2630 · SKU Cahnos AMP642DS2630.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament with a grooved finish, the strand slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, minimises the inflammatory reaction and favours knot retention.
The DS26 Prime needle, 26 mm, has a 3/8 circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound bed, preserving the skin edge and preventing the cut from widening, facilitating passage through firm, non-distensible tissues. The grooved body of the needle improves the grip of the needle holder and the transmission of rotation. The USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous closures and ligatures, and the 45 cm thread is ideal for ophthalmology, neurosurgery and precision sutures.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer / distributor (Cahnos S.L.).
3.1. General characteristics
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon (polyamide 6 or 6.6), uncoated monofilament |
| Structure | Monofilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 3/0 (metric EP 2), in accordance with USP and European Pharmacopoeia gauges. |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 45 cm |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | DS26 Prime (26 mm) |
| Swaged | 1 needle per unit |
| Sterilisation | Ethylene oxide (EO), sterile; single use, do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P642DS2630 |
| Reference Cahnos (SKU) | AMP642DS2630 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT Prime family with DS26 needle (3/8 circle, reverse cutting, black thread)
| Needle profile | USP size | Thread | Reference (SKU Cahnos) |
|---|---|---|---|
| DS26 Prime | 3/0 | 1 × 75 cm (black) | AMP641DS2630 |
| DS26 Prime | 3/0 | 1 × 45 cm (black) | AMP642DS2630 (this product) |
| DS26 Prime | 3/0 | 2 × 75 cm (black) | AMP642DS2630.2 |
| DS26 Prime | 4/0 | 1 × 45 cm (black) | AMP641DS2640 |
| DS26 Prime | 2/0 | 1 × 45 cm (black) | AMP641DS2620 |
4. Equivalences and Cross-References
The reference P642DS2630 corresponds to the official nomenclature of the PREMISUT Prime range (DS26 profile: 3/8 circle needle with reverse cutting triangular point, 26 mm, USP 3/0 gauge, black grooved thread, 45 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination of USP 3/0 + 3/8 circle reverse cutting needle, 26 mm + black thread, 45 cm; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHILON™ – black nylon monofilament, 3-0, 45 cm, PS Prime needle, 26 mm, 3/8 circle, reverse cutting | W1625BH (verified in official Ethicon EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), gauge 3/0, black colour, length 45 cm, 3/8 circle radius and 26 mm needle with reverse cutting point; they differ in needle profile (PS Prime vs DS Prime) and presentation (box of 36 units vs 12 units). Confirm IFU and CE/MDR classification before substituting. |
| B. Braun | DAFILON® Blue – polyamide monofilament, 3/0 (EP 2), 45 cm, DS24 needle, 3/8 circle, reverse cutting | C0932353 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), gauge (EP 2), length 45 cm and curvature with reverse cutting point; they differ in colour (blue vs black) and needle (DS24, 24 mm vs DS26, 26 mm). Confirm IFU before substituting. |
| Medtronic (Covidien) | MONOSOF™ – black nylon monofilament, 3-0, 45 cm (18″), C-14 needle, 3/8 circle, reverse cutting | SN-663G (verified in Medtronic/Covidien product data sheet and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (nylon 6 and 6.6), gauge 3/0, black colour, length and reverse cutting geometry; they differ in needle (C-14, 24 mm vs DS26, 26 mm) and commercial presentation. Confirm data sheet before substituting. |
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (DS26 Prime, USP 3/0, black thread, 45 cm) is only fully safely interchangeable within the PREMISUT system itself. Other homologous families on the market (e.g. DemeLON from DemeTECH or LUXAMID from LuxSutures) require property-by-property verification of material, gauge, curvature, point family, needle and thread length, colour and regulatory classification before any substitution.
5. Selection tips and variants of interest
Tissue to suture: the USP 3/0 (EP 2) gauge offers the optimal balance between fineness and strength for skin, subcutaneous tissue and soft tissues with medium tension. The DS26 reverse cutting needle passes through firm, non-distensible tissues without tearing the puncture bed, being especially indicated in ophthalmology, neurosurgery and ligatures; for finer planes consider the 4/0 of the same family (AMP641DS2640).
Thread length: this reference is 45 cm, the usual length for precision and interrupted sutures. The same DS26 Prime needle is available with 75 cm thread (AMP641DS2630) and in double format 2×75 cm (AMP642DS2630.2) for longer procedures or continuous sutures.
Portfolio unification: the same DS26 Prime needle is available in USP 2/0, 3/0 and 4/0, allowing supplier unification across the entire range of non-absorbable nylon sutures. If an extra-long precision cutting edge with a square body (XDS profile) is required, the XDS26 family is available (e.g. AMP641XDS2630 or AMP642XDS2630) for plastic and cosmetic surgery.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642DS2630 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
B2B conditions: for volume hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.