Description
1. Product Presentation
The NYLON PREMISUT Prime suture, factory reference P642DR1360 (SKU Cahnos AMP642DR1360), is the precision choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour and excellent handling. It features a ⅜ circle needle with a cylindrical body and a 13 mm conical taperpoint (DR13 Prime profile), USP 6/0 gauge and 45 cm black thread: a fine, atraumatic configuration designed for approximation of delicate soft tissues, ligatures, ophthalmology and neurosurgery. Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets.
2. Technical Explanation
The thread is made of uncoated nylon monofilament (polyamide 6 or 6.6), a synthetic polymer with a smooth surface that offers very smooth passage through tissue, without wicking effect, with minimal bacterial adherence and low tissue reaction. Being non-absorbable, it does not degrade by enzymatic action: it undergoes gradual encapsulation by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with cylindrical body and 13 mm conical taperpoint separates and displaces fibres without cutting them, minimising trauma to delicate, friable and thin-walled vascular structures. The Prime finish provides optimised penetration and consistent grip in the needle holder. The USP 6/0 gauge (metric 0.7) is one of the finest in the range, ideal for precision sutures in microsurgery. The black colour ensures immediate contrast of the thread against the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric 0.7); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Conical taperpoint (DR13 Prime profile) |
| Needle size | 13 mm (DR13 Prime) |
| Configuration | Single needle (1 × 45 cm) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P642DR1360 |
| Reference Cahnos (SKU) | AMP642DR1360 |
3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 6/0 | 0.7 | 0.070 – 0.099 mm |
3.2. Premisut Prime DR13 family (⅜ circle needle, cylindrical body, conical taperpoint)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| DR 13 Prime | 6/0 | 1 × 45 cm (black) | P642DR1360 / AMP642DR1360 (this product) |
| DR 13 Prime | 6/0 | 1 × 75 cm (black) | P642DR1360-75 / AMP642DR136075 (check availability) |
| DR 13 Prime | 5/0 | 1 × 75 cm (black) | P642DR1350 / AMP642DR1350 |
| DR 13 Prime | 4/0 | 1 × 75 cm (black) | P642DR1340 / AMP642DR1340 |
| 2×DR 13 Prime (double needle) | 6/0 | 2 × 75 cm (blue) | P732DR1360-2 / AMP732DR1360-2 |
4. Equivalences and Cross-References
The reference P642DR1360 corresponds to the official nomenclature of the Premisut Prime range (DR13 profile, 13 mm conical taperpoint needle, USP 6/0 gauge, 45 cm black thread) and Cahnos markets it without altering characters. Non-absorbable black nylon monofilament is one of the most standardised permanent suture families on the market (commercially type «Ethilon»). There is no manufacturer-validated equivalence table that cross-references this product with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. The main difference compared with the cited external references is the point type: conical taperpoint versus the 13 mm precision reverse-cutting variants in ⅜ circle.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Nylon DR13 Prime, USP 6/0, black, 45 cm | P642DR1360 / AMP642DR1360 | Reference of the analysed product | Code verified in Cahnos internal catalogue without altering characters |
| Ethicon (J&J MedTech) | ETHILON® – black monofilament nylon, 6-0, 45 cm, 13 mm P-3 needle, ⅜ circle | 1698G | Comparable by category (not interchangeable 1:1) – code confirmed | Same material (polyamide), gauge, colour, length (45 cm) and ⅜ 13 mm needle radius; the point differs (precision reverse-cutting P-3 versus conical taperpoint DR13). Verified in Ethicon catalogue and authorised distribution (Ebos, Delasco, Amazon) |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 6-0, 45 cm, P-3 ⅜ circle 13 mm needle | 1698H | Comparable by category (not interchangeable 1:1) – code confirmed | P-3 configuration of 13 mm, 6/0 and 45 cm; verify point presentation (reverse cutting) versus taperpoint in official data sheet before substituting |
| Medtronic (Covidien) | Monosof™ – black monofilament nylon | Consult official catalogue for 6/0 DR13 taperpoint | Pending confirmation | Non-absorbable nylon monofilament family in the sector with similar clinical indication; confirm code, needle radius and point (conical versus cutting) in IFU before substituting |
| B. Braun (Aesculap) | Dafilon® – black nylon monofilament | Consult official catalogue for 6/0 with ⅜ 13 mm conical needle | Pending confirmation | Matching base material (polyamide monofilament); confirm exact code, needle geometry and length in B. Braun official catalogue |
| Suturex | Nylon 6/0, 3/8 circle, 13 mm, 45 cm, black | XN667S / XN1698S | Comparable by category (not interchangeable 1:1) – code confirmed at distributor | Same measurements (6/0, 3/8, 13 mm, 45 cm, black); cutting point versus conical taperpoint; registration and regulatory classification to be validated locally |
Mandatory technical note: there is no manufacturer-validated equivalence table that cross-references this product with other brands; comparisons with ETHILON®, Monosof™, Dafilon® or Suturex are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. This needle geometry (DR13 taperpoint, USP 6/0, 45 cm) is only safely interchangeable within the Premisut system itself. Consult Cahnos technical department to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery) and fine skin. The conical taperpoint needle separates fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for firm or poorly distensible tissues consider reverse-cutting profiles from the same Premisut nylon range (e.g. AMP642XDS1360, XDS13 in 6/0).
- Thread length: this 45 cm reference offers good margin for passes and knots in reduced surgical fields; if the protocol requires more thread, a 75 cm variant is available within the same DR13 family (check availability in the catalogue).
- Portfolio unification: the same DR13 Prime needle is offered in USP 5/0 and 4/0, and in polypropylene (AMP732DR1360, 6/0 blue 75 cm) and silk (AMP542DR1360, 6/0 black 75 cm) to unify supplier across the entire permanent suture portfolio.
- Other geometries: if the protocol requires a ½ circle radius with conical point, the Prime ½ circle HR20 variant is available in 6/0 (AMP642HR2060); for precision triangular point, the XDS13 in 6/0 (AMP642XDS1360).
- Sterility verification: product sterile by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P642DR1360 and batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews