Description
1. Commercial Introduction
The nylon suture PREMISUT PRIME is the reference choice for operating theatres, purchasing departments and tenders that need a non-absorbable suture with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 7/0 gauge (metric EP 0.5) mounts a ⅜ circle cylindrical-body needle with a taperpoint conical point of 9.3 mm (DR 9.3 Prime profile) and a 45 cm black suture, designed for soft tissue surgery, ligatures and precision specialties such as ophthalmology and neurosurgery. It is supplied sterile and ready for single use in a box of 12 units with batch traceability. It is marketed under SKU AMP641DR9,370 (article reference P641DR9,370) in a B2B format ideal for hospital replenishment and public tenders.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months. The DR 9.3 Prime needle (⅜ circle, cylindrical body with sharp taperpoint conical point) penetrates soft tissues by separating fibres without cutting them, which reduces tissue trauma and is especially valued in delicate ocular, vascular and nervous structures. The USP 7/0 gauge (metric EP 0.5) offers an optimal balance between fineness and strength for approximation of soft tissues and ligatures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Black (blue also available in the range) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Cylindrical body, conical tip (taperpoint) |
| Needle size | 9.3 mm (DR 9.3 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Article reference | P641DR9,370 |
| Reference Cahnos (SKU) | AMP641DR9,370 |
3.2. Family Premisut Prime DR in nylon (⅜ circle, cylindrical, conical point) – 15 cm presentations
| Needle profile | USP | Presentation | References |
|---|---|---|---|
| DR 3.8 Prime | 11/0 | 1 × 15 cm | P649DR3.8110 / AMP649DR3.8110 |
| DR 3.8 Prime | 10/0 | 1 × 15 cm | P649DR3.8100 / AMP649DR3.8100 |
| DR 3.8 Prime | 9/0 | 1 × 15 cm | P649DR3,890 / AMP649DR3,890 |
| DR 4.7 Prime | 9/0 | 1 × 15 cm | P649DR4,790 / AMP649DR4,790 |
| DR 5.1 Prime | 9/0 | 1 × 15 cm | P649DR5,190 / AMP649DR5,190 |
| DR 5.1 Prime | 10/0 | 1 × 15 cm | P649DR5.1100 / AMP649DR5.1100 |
| DR 5.1 Prime | 11/0 | 1 × 15 cm | P649DR5.1110 / AMP649DR5.1110 |
| DR 6.5 Prime | 8/0 | 1 × 15 cm | P649DR6,580 / AMP649DR6,580 |
| DR 6.5 Prime | 9/0 | 1 × 15 cm | P649DR6,590 / AMP649DR6,590 |
| DR 6.5 Prime | 10/0 | 1 × 15 cm | P649DR6.5100 / AMP649DR6.5100 |
3.3. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | EP metric measure | Indicative diameter | Thread length |
|---|---|---|---|
| 7/0 | 0.5 | 0.050 – 0.069 mm | 45 cm |
4. Equivalences and Cross-References
The reference AMP641DR9,370 corresponds to the nomenclature of the Premisut Prime range (DR 9.3 Prime profile, individual taperpoint conical-point needle of 9.3 mm, USP 7/0 gauge, black 45 cm suture); its article reference is P641DR9,370. Cahnos markets the product keeping its own SKU without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands: the following comparisons are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or instructions for use (IFU) before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, microsurgery, cylindrical needle ⅜ circle conical point | W8170 (black suture 45 cm, BV-1 needle; verified in official catalogue and authorised distributors) | Functional category equivalence, not 1:1 interchangeable (code confirmed, different gauge) | They match in material (polyamide), black colour, ⅜ radius, conical point and 45 cm length; BV-1 needle of 9 mm (220 μ) versus DR 9.3 Prime. Key difference: W8170 is black ETHILON USP 8/0 (metric 0.4), one gauge finer than the 7/0 (0.5) of this reference; it is usually mounted with a double needle (2×BV-1). It is not a 1:1 substitute for the gauge. |
| B. Braun | DAFILON® – polyamide (nylon) uncoated monofilament, black/blue, USP 2 to USP 10/0 gauges | Family verified in official catalogue; for black 7/0 (0.5) 45 cm GUDID/FDA records versions with DSMP needle (triangular micro-point): C0977212 / C0977225 | Comparable by category (code with conical needle unconfirmed) | Same material (polyamide monofilament), same colour and use. The official DAFILON® range covers USP 7/0, but no specific reference with a round-body conical-point needle of 9.3 mm and 45 cm suture has been validated in public sources: the black 7/0 45 cm versions located mount a DSMP triangular micro-point needle, a tip geometry different from the DR taperpoint. Confirm with B. Braun before proposing substitution. |
| Premisut Prime range (Cahnos) | Nylon DR 6.5 Prime, USP 10/0, black, 15 cm | P649DR6.5100 / AMP649DR6.5100 | Configuration equivalent within the same system (not 1:1 in measurements) | Same material, same conical taperpoint needle geometry; finer 10/0 gauge, 6.5 mm needle and 15 cm suture versus the 9.3 mm and 45 cm of this reference. |
Mandatory technical note: there is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the comparisons with ETHILON® and DAFILON® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. This needle geometry (DR 9.3 taperpoint, USP 7/0, 45 cm) is only fully safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the USP 7/0 (EP 0.5) gauge is a fine, highly manageable suture, indicated for approximation of soft tissues, ligatures, ophthalmology and neurosurgery. The DR conical-point (taperpoint) needle separates fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for planes requiring firmer penetration (skin, fascia), consider triangular-point profiles from the same Premisut Prime range.
Needle size: the DR 9.3 mm needle is one of the longest conical needles in the DR family, suitable for medium working surgical fields. If you need greater fineness, the range offers DR 3.8 (11/0 to 9/0), DR 4.7, DR 5.1 (9/0 to 11/0) and DR 6.5 (8/0 to 10/0) profiles in 15 cm suture, all in black Prime nylon.
Alternative presentations: for continuous or double-anchoring techniques, the same range offers double-needle versions (e.g. 2×DR 6.5 in 10/0 with 30 cm thread, AMP644DR6.5100-2), as well as spatula needles specific to ophthalmology (DSP/HSP range) and the braided silk variant with the same DR 9.3 needle (AMP544DR9,370).
Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference AMP641DR9,370 and the batch number for traceability in the operating theatre and in the event of a claim. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.