Description
1. Commercial Introduction
The nylon PREMISUT PRIME suture is the reference choice for operating theatres, purchasing departments and tenders that require a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 8/0 gauge mounts a ⅜ circular needle with a cylindrical body and a conical point of 6.5 mm (DR 6.5 Prime profile) and a 15 cm black thread, designed for high-demand surgery: ophthalmology, neurosurgery, vascular microsurgery and precision procedures on soft tissues. It is supplied sterile and ready for individual use in a box of 12 units with batch traceability.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months. The DR 6.5 Prime needle (⅜ circle, cylindrical body with sharp conical taperpoint tip) penetrates soft tissues by separating fibres without cutting them, which reduces tissue trauma and is especially valued in delicate ocular, vascular and nervous structures. The USP 8/0 gauge (EP metric 0.4) is an ultra-fine thread with adequate strength for approximating very fine tissues with minimal residue. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 8/0 (metric EP 0.4); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 15 cm |
| Thread colour | Black (standard in microsurgery and ophthalmology) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Cylindrical body, conical tip (taperpoint) |
| Needle size | 6.5 mm (DR 6.5 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P649DR6,580 |
| Reference Cahnos (SKU) | AMP649DR6,580 |
3.2. Premisut Prime DR family in nylon (⅜ circle, cylindrical, conical tip) – 15 cm presentation
| Needle profile | USP | Presentation | Reference |
| DR 6.5 Prime | 8/0 | 1 × 15 cm | P649DR6,580 (this product) |
| DR 6.5 Prime | 9/0 | 1 × 15 cm | P649DR6,590 / AMP649DR6,590 |
| DR 6.5 Prime | 10/0 | 1 × 15 cm | P649DR6.5100 / AMP649DR6.5100 |
| DR 5.1 Prime | 9/0 | 1 × 15 cm | P649DR5,190 / AMP649DR5,190 |
| DR 4.7 Prime | 8/0 | 1 × 15 cm | P649DR4,780 / AMP649DR4,780 |
| DR 3.8 Prime | 9/0 | 1 × 15 cm | P649DR3,890 / AMP649DR3,890 |
3.3. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | EP metric measure | Thread length |
| 8/0 | 0.4 | 15 cm |
4. Equivalences and Cross-References
The reference P649DR6,580 corresponds to the official nomenclature of the Premisut Prime range (DR 6.5 Prime profile, individual needle with 6.5 mm taperpoint conical tip, USP 8/0 gauge, 15 cm black thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, USP 8/0, 13 cm (5″), BV130-5 needle ⅜ circle conical tip of 6.5 mm | 2808G | Functional equivalence by specifications (verified in official Ethicon catalogue and authorised distribution) | Material (polyamide 6/6.6), gauge 8/0, black colour, ⅜ radius and 6.5 mm conical needle match; thread 13 cm versus 15 cm; confirm presentation and batch against IFU |
| B. Braun | DAFILON® – black polyamide monofilament, USP 8/0 (EP 0.4), 15 cm, DRm6 micro-needle ⅜ circle round body 6.0 mm | G1118170 | Functional equivalence by specifications (verified in official B. Braun catalogue) | High match: gauge 8/0 (0.4), length 15 cm, black colour and ⅜ shape; micro DRm6 needle of 6.0 mm versus 6.5 mm taperpoint; confirm tip geometry against IFU |
| B. Braun | DAFILON® – black polyamide monofilament, USP 8/0 (EP 0.4), 15 cm, PRm6 micro needle (140 µm) | G1118390 | Comparable by category (verified in official B. Braun catalogue) | Same gauge, colour and length; PRm6 micro needle of 140 µm versus 6.5 mm taperpoint conical tip |
| Premisut Prime range (Cahnos) | Nylon DR 6.5 Prime, USP 9/0, black, 15 cm | P649DR6,590 / AMP649DR6,590 | Configuration equivalent within the same system | Same 6.5 mm conical needle and same material; gauge 9/0 finer versus 8/0 |
| Premisut Prime range (Cahnos) | Polypropylene DR 6.5 Prime, USP 9/0, blue, 15 cm | P739DR6,590 / AMP739DR6,590 | Comparable by category (same needle system) | Same 6.5 mm needle and mounting shape; polypropylene material (not polyamide), gauge 9/0 and blue colour |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with ETHILON® and DAFILON® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (DR 6.5 taperpoint, USP 8/0, 15 cm) is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the USP 8/0 gauge (EP 0.4) is an ultra-fine thread indicated for approximation of very delicate soft tissues, ligatures, ophthalmology and neurosurgery. The DR needle with conical point (taperpoint) separates fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for planes requiring firmer penetration (skin, fascia), consider triangular tip profiles from the same Premisut Prime range.
Gauge: if you need even finer with the same DR 6.5 needle, the 9/0 (AMP649DR6,590) and 10/0 (AMP649DR6.5100) are available. If you prefer a bit more strength while keeping 8/0, there are slightly shorter needles in the range, such as the DR 4.7 (AMP649DR4,780).
Needle size: the DR 6.5 mm offers a longer needle for somewhat wider working fields; for planes of maximum fineness there are DR 5.1 and DR 3.8 profiles (e.g. AMP649DR3,890) in gauges 9/0 to 11/0.
Material alternatives: if the protocol prefers polyolefin over polyamide, the Premisut Prime range offers polypropylene with the same DR 6.5 needle in gauge 9/0 (AMP739DR6,590). Unifying supplier across the entire permanent suture portfolio allows B2B volume conditions.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P649DR6,580 and the batch number for traceability in the operating theatre and in case of complaint. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews