Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 1/2 Cylindrical HR40 (Manufacturer ref. P645HR40L01 · SKU AMP645HR40L01) is the premium reference from Cahnos among non-absorbable nylon sutures for procedures requiring a high-performance permanent thread. It combines a monofilament of polyamide 6 or 6.6, identifying black colour, USP 1 gauge and 150 cm of grooved thread in a loop presentation, mounted on a Prime needle of ½ circle with cylindrical body and taperpoint conical point of 40 mm (HR40 profile).
Prime quality guarantees consistent sharpening batch after batch and predictable penetration in each stitch, being especially valued in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres that need a permanent thread with full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely. It gradually becomes encapsulated by connective tissue and maintains a high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the strand slides easily through tissues, reduces the wicking effect and bacterial drag compared to multifilament, and minimises the inflammatory reaction. The grooved surface finish improves knot retention and handling.
The 40 mm HR40 Prime needle features a ½ circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues separating the fibres without cutting them, making it especially suitable for soft and well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva). The USP 1 gauge (metric EP 4) provides high tensile strength, and the 150 cm loop thread allows continuous sutures or multiple ligatures without the need to re-attach the needle. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 150 cm in loop (loop) |
| Thread colour | Identifying black, grooved (high visibility on the surgical field) |
| Needle shape | ½ circle (½ circular), cylindrical body |
| Tip type | Conical / cylindrical (Taperpoint) |
| Needle size | HR 40 Prime (40 mm) |
| Configuration | 1 needle per unit, 150 cm thread in loop (loop 1) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, away from moisture and direct sunlight |
| Factory reference | P645HR40L01 |
| Reference Cahnos (SKU) | AMP645HR40L01 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT HR40 family (½ circle needle, 40 mm, taperpoint conical point, black loop thread)
| Needle profile | USP size | Thread | Reference |
| HR40 Prime | 1 | 1 × 150 cm loop (black) | P645HR40L01 / AMP645HR40L01 (this product) |
| HR40 Prime | 0 | 1 × 150 cm loop (black) | P645HR40L10 / AMP645HR40L10 |
| HR40 (standard range) | 1 | 1 × 150 cm loop (black) | 645HR40L01 / AM645HR40L01 |
| HR30 Prime | 1 | 1 × 150 cm loop (black) | P645HR30L01 / AMP645HR30L01 |
| HR35 Prime | 1 | 1 × 150 cm loop (black) | P645HR35L01 / AMP645HR35L01 |
| HR50 Prime | 1 | 1 × 150 cm loop (black) | P645HR50L01 / AMP645HR50L01 |
4. Equivalences and Cross-References
The reference P645HR40L01 corresponds to the official nomenclature of the PREMISUT Prime range (HR40 profile: ½ circle needle with cylindrical body and taperpoint conical point of 40 mm, USP 1 gauge, black 150 cm loop thread, grooved) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially type «Ethilon»).
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands for the exact combination of USP 1 + ½ circle taperpoint needle of 40 mm + black 150 cm loop thread. References have been found in official sources (manufacturer catalogue and regulatory databases such as GUDID) that match in material, gauge, colour and loop configuration, with a difference in needle size:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson) | ETHILON® – black nylon monofilament, USP 1 (EP 4), 150 cm loop, CTX needle of ½ circle conical point (taperpoint) of 48 mm | W748 (verified in official Ethicon EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge (EP 4), black colour, ½ circle curvature, conical point family and 150 cm loop thread. The needle size differs: CTX 48 mm versus HR40 of 40 mm (outside the ±1 mm tolerance). Confirm the technical data sheet or IFU before any substitution. |
| DemeTECH | DemeLON® – black nylon monofilament, USP 1, 150 cm loop, DCTX LOOP needle of ½ circle conical point (taperpoint) of 48 mm | NL560148BI1P (verified in official DemeTECH store and GUDID/FDA) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge, black colour, loop configuration, ½ circle curvature and conical point family. The needle size differs: 48 mm versus 40 mm (outside the ±1 mm tolerance). Confirm IFU and regulatory classification before substituting. |
Homologous market families that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON™, B. Braun Dafilon®, Medtronic Monosof™/Dermalon™, SMI SUPRAMID, LuxSutures Luxamid and DemeTECH DemeLON. No codes from these manufacturers have been verified in public sources for the exact HR40 configuration of 40 mm, USP 1 and black 150 cm loop thread; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or instructions for use (IFU) of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR40 Prime, USP 1, 150 cm loop) is only safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: USP 1 (EP 4) gauge offers high tensile strength for subcutaneous tissue, fasciae, aponeuroses and soft tissues under high tension, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 0 of the same geometry (Ref. AMP645HR40L10).
Needle length: the 40 mm HR40 profile covers medium-depth access. For smaller fields, the HR30 (Ref. AMP645HR30L01) and HR35 (Ref. AMP645HR35L01) are available; for deeper access, the HR50 (Ref. AMP645HR50L01), all in USP 1 with a 150 cm loop.
Thread presentation: this product comes as a 150 cm loop, practical for ligatures, continuous sutures and deep-field surgery without re-threading. The exact same configuration in the standard range (not Prime) corresponds to Ref. 645HR40L01 (SKU AM645HR40L01), a direct equivalent within the same manufacturer.
Prime vs. standard quality: the Prime range offers maximum sharpness and batch-to-batch consistency. The standard version AM645HR40L01 maintains identical dimensional specifications with standard sharpening performance.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P645HR40L01 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews