Description
1. Commercial Introduction
The NYLON SUTURE PREMISUT Prime (factory ref. P642HR2050 · SKU Cahnos AMP642HR2050) is Cahnos’ premium reference within non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread, mounted on a cylindrical-body needle with a conical point. It combines a black, identifying nylon monofilament (polyamide 6 or 6.6), USP gauge 5/0 (metric EP 1) and a smooth, uncoated 75 cm strand, mounted on a Prime needle of ½ circle and taperpoint tip of 20 mm (HR20 profile). It is a common choice in ophthalmology, neurosurgery, general surgery departments and purchasing centres that value batch-to-batch consistency and full traceability of the Prime range. Sterile, ready-to-use product, presented in a box of 12 individual sachets in B2B format for hospital replenishment and tenders. A single sterile sachet contains one swaged needle and its strand, with full batch traceability.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical phase of healing. Being an uncoated, smooth monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The black colour ensures optimal contrast on the surgical field, especially in precision specialties. The 20 mm HR20 Prime needle features a ½-circle curvature with a cylindrical body and conical (taperpoint) point: the sharp point without cutting edges passes through tissues by separating fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimal trauma is sought. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P642HR2050 |
| Reference Cahnos (SKU) | AMP642HR2050 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.10 – 0.149 mm |
| Thread length | 75 cm (single strand, no loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint |
| Needle size | HR 20 Prime (20 mm) |
| Configuration | 1 needle × 75 cm per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
| 5/0 (this product) | 1 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its established limits.
3.3. PREMISUT Prime family in nylon (½ circle needle, taperpoint conical point HR20, black thread)
| Needle profile | USP size | Thread | Reference |
| HR 20 Prime | 6/0 | 1 × 75 cm (black) | P642HR2060 / AMP642HR2060 |
| HR 20 Prime | 5/0 | 1 × 75 cm (black) | P642HR2050 / AMP642HR2050 (this product) |
| HR 20 Prime | 4/0 | 1 × 75 cm (black) | P642HR2040 / AMP642HR2040 |
| HR 20 Prime | 3/0 | 1 × 75 cm (black) | P642HR2030 / AMP642HR2030 |
| HR 20 Prime | 2/0 | 1 × 75 cm (black) | P642HR2020 / AMP642HR2020 |
| HR 20 standard | 5/0 | 1 × 75 cm (black) | 642HR2050 / AM642HR2050 |
The same conical needle is offered in HR20 (shorter), HR26, HR30, HR37 and HR40 (longer travel) profiles and in USP gauges 6/0, 5/0, 4/0, 3/0, 2/0, 0 and 1 depending on the plane to be sutured.
4. Equivalences and Cross-References
The reference P642HR2050 corresponds to the official nomenclature of the PREMISUT Prime range (HR20 profile: ½-circle needle with 20 mm taperpoint conical point, USP gauge 5/0, black smooth 75 cm thread) and Cahnos markets it without altering characters: no digit may be added, removed or rearranged when ordering or tendering. Non-absorbable black nylon monofilament is one of the most standardised permanent suture families in the surgical market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table that cross-references this specific configuration (½-circle needle with 20 mm HR20 conical point, USP gauge 5/0, black, 75 cm strand) with references from other houses; therefore, the matches shown below are functional comparisons at category level, not interchangeable 1:1 without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 5/0 (EP 1), 75 cm, DS16 needle (⅜ circle, triangular body, cutting point) | C0935123 | Comparable by category (not interchangeable 1:1) | They match material (uncoated polyamide), USP gauge 5/0 (EP 1) and thread length (75 cm); they differ in needle geometry (⅜ circle cutting DS16 of 16 mm vs. ½ circle taperpoint HR20 of 20 mm) and colour (blue vs. black). Code confirmed in official B. Braun catalogue. |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, 5-0, 45 cm, PC-3 needle (⅜ circle, conventional cutting 16 mm) | 1865G | Comparable by category (not interchangeable 1:1) | They match material (polyamide), gauge 5/0, black colour and needle size of 16 mm; they differ in geometry (⅜ circle conventional cutting vs. ½ circle taperpoint HR20) and strand length (45 vs. 75 cm). Code confirmed in official Ethicon catalogue. |
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. This needle geometry (HR20 Prime, USP 5/0, 75 cm strand) is only fully safely interchangeable within the PREMISUT system itself: the standard-range variant of identical configuration is Ref. 642HR2050 (SKU AM642HR2050). Other homologous non-absorbable nylon monofilament families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / J&J MedTech), DAFILON® (B. Braun / Aesculap), MONOSOF™ and DERMALON™ (Medtronic / Covidien), DEMELON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these houses have been verified in public sources for the exact HR20 20 mm, USP 5/0, conical point and black 75 cm strand configuration; they must be confirmed with the manufacturer before use in substitution or tendering. The cited brands belong to their respective manufacturers and are mentioned only as equivalence reference.
5. Selection tips and variants of interest
Tissue to be sutured: the USP 5/0 (metric EP 1) gauge is the precision choice for fine and delicate planes: skin, mucous membranes, subcutaneous tissue, soft tissues with low-medium tension and ligatures, always with a conical-point needle to minimise tissue damage. For even finer planes consider USP 6/0 (Ref. AMP642HR2060); for higher loads, USP 4/0 (Ref. AMP642HR2040), 3/0 (Ref. AMP642HR2030) or 2/0 (Ref. AMP642HR2020) of the same Prime needle.
Needle length: the 20 mm HR20 profile is the ideal option for surgical fields with very limited reach (ophthalmology, minor surgery, paediatric surgery and neurosurgery). For medium-depth access, the HR26, HR30, HR37 and HR40 profiles of the same Prime range are available.
Alternative point: if the protocol requires a cutting needle for skin or mucous membranes, the Premisut Prime range offers the same gauge in precision triangular point (XNS 16) and in reverse cutting profiles, always with prior validation of the technical data sheet.
Prime vs. standard quality: the Prime range provides maximum sharpening precision and batch-to-batch consistency; if the cost per unit is critical, the standard range (Ref. AM642HR2050) maintains the same dimensional specifications with standard sharpening.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642HR2050 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.