Description
1. Commercial Introduction
The NYLON PREMISUT Prime 1/2 Cylindrical HR26 suture (factory ref. P642RHR2601.2 · SKU Cahnos AMP642HR2601.2) is the reference of the premium range of Cahnos within non-absorbable nylon sutures for procedures that require a permanent, manageable, high-performance thread. It combines a black identification monofilament of polyamide 6 or 6.6, USP 1 gauge (metric EP 4) and a double 75 cm strand without coating, mounted on a Prime ½ circle needle with a 26 mm taperpoint conical tip (HR26 profile).
It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tenders that require a permanent thread with predictable clinical behaviour, complete batch traceability and maximum batch-to-batch consistency. Sterile, ready-to-use product, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared to multifilaments, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention, while the black colour ensures optimal contrast on the surgical field.
The 26 mm HR26 Prime needle features a ½ circle curvature with a cylindrical body and conical tip (taperpoint): the sharp tip without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The double strand presentation 2 × 75 cm allows continuous sutures or multiple stitches without re-threading, optimising performance in high-consumption surgical programmes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P642RHR2601.2 |
| Reference Cahnos (SKU) | AMP642HR2601.2 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm |
| Thread length | 2 × 75 cm (double strand, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 26 Prime (26 mm) |
| Configuration | 2 needles per unit, 2 strands of 75 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.45 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its limits.
3.3. PREMISUT HR26 Prime family (½ circle 26 mm needle, taperpoint conical point, black thread)
| Needle profile | USP size | Thread | Reference |
| HR 26 Prime | 4/0 | 1 × 75 cm (black) | P642HR2640 / AMP642HR2640 |
| HR 26 Prime | 3/0 | 1 × 75 cm (black) | P642HR2630 / AMP642HR2630 |
| HR 26 Prime | 2/0 | 1 × 75 cm (black) | P642HR2620 / AMP642HR2620 |
| HR 26 Prime | 0 | 1 × 75 cm (black) | P642HR2610 / AMP642HR2610 |
| HR 26 Prime | 1 | 1 × 75 cm (black) | P642HR2601 / AMP642HR2601 |
| HR 26 Prime | 0 | 2 × 75 cm (black, double thread) | P642RHR2610.2 / AMP642HR2610.2 |
| HR 26 Prime | 3/0 | 2 × 75 cm (black, double thread) | P642RHR2630.2 / AMP642HR2630.2 |
| HR 26 Prime | 2/0 | 2 × 75 cm (black, double thread) | P642RHR2620.2 / AMP642HR2620.2 |
| HR 26 Prime | 1 | 2 × 75 cm (black, double thread) | P642RHR2601.2 / AMP642HR2601.2 (this product) |
The same HR26 conical needle is available in other gauges (USP 4/0, 3/0, 2/0 and 0) and this family continues in shorter needle profiles (HR20) or longer ones (HR30, HR37, HR40, HR50, series 643) for procedures of shorter or longer travel.
4. Equivalences and Cross-References
The reference P642RHR2601.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR26 profile: ½ circle needle with 26 mm taperpoint conical tip, USP 1 gauge, black grooved 75 cm thread in double presentation) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type “Ethilon”). There is no manufacturer-validated equivalence table that cross-references this specific configuration (½ circle needle with 26 mm HR26 conical tip, USP 1 gauge, black, double 75 cm strand) with references from other houses; therefore, the following matches are functional comparisons, at category level, and should not be treated as 1:1 interchangeable without prior technical validation. The cited codes have been checked against the official catalogue and the GUDID/FDA regulatory databases of the corresponding manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | DAFILON® – uncoated polyamide monofilament, gauge 0 (EP 3.5), blue 75 cm thread, HR26 needle (½ circle, round body, conical tip) | C0930431 (verified in official B. Braun catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), ½ circle curvature, conical tip family and needle size (HR26 of 26 mm, identical); they differ in gauge (USP 0 vs 1), thread colour (blue vs black) and presentation (1 thread vs 2 threads). Confirm IFU and CE/MDR classification before substituting. |
| Atramat (Internacional Farmacéutica, S.A. de C.V.) | Atramat Nylon – black nylon monofilament surgical suture, USP 0 (EP 3.5), 75 cm, R-26 needle conical tip 26 mm ½ circle | R2641-75N (GUDID 07500142001932) | Comparable by category (not interchangeable 1:1) | They match in material (nylon 6/6.6), black colour, ½ circle curvature, conical tip and needle size (R-26, 26 mm); they differ in gauge (USP 0 vs 1) and presentation (1 thread of 75 cm vs double thread 2×75 cm). Confirm commercial presentation and CE/MDR classification before tendering. |
Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, tip family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: Ethilon™ (Ethicon / J&J MedTech), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner) and SUPRAMID® (SMI). No codes from these houses have been verified in public sources for the exact HR26 26 mm configuration, USP 1, conical tip and black 75 cm strand in double presentation; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer for this configuration; check the technical data sheet or instructions for use of the alternative manufacturer for the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR26 Prime, USP 1, double thread of 75 cm) is only safely interchangeable within the PREMISUT system itself. Consult the technical department at Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: USP 1 gauge (metric EP 4) offers high tensile strength for subcutaneous tissue, fasciae and soft tissues under moderate tension, always with a conical point needle to minimise tissue damage. For finer planes, consider USP 0 (Ref. AMP642HR2610.2) or USP 2/0 (Ref. AMP642HR2620.2) from the same Prime family.
- Needle length: the HR26 profile of 26 mm is the standard choice in ophthalmology and neurosurgery for medium-depth access. For smaller fields, the HR20 family (Ref. AMP642HR2020) is available, and for longer travel fields, the HR30, HR37 (Ref. AMP642HR3710.2) or HR40 profiles from the same Prime range.
- Double presentation: this reference provides 2 threads of 75 cm per pack, ideal for continuous sutures without re-threading or for distributing the material across two surgical fields. If the protocol only requires one strand, the same needle and gauge are available in a 1 × 75 cm presentation (Ref. AMP642HR2601).
- Prime vs. standard quality: if the procedure requires maximum sharpening precision and batch-to-batch consistency, the Prime range is the right choice; if the cost per unit is a critical factor, the standard range (Ref. AM642HR2601) maintains the same dimensional specifications with standard sharpening performance.
- Colour: in ophthalmology, black thread is preferred for its contrast against the field; in plastic surgery or skin closure, blue may be acceptable, available in other references in the range.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642RHR2601.2 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.