Description
1. Commercial Introduction
The NYLON PREMISUT Prime Suture (factory ref. P642HR2020.2 · SKU Cahnos AMP642HR2020.2) is Cahnos’s premium reference within non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread, mounted on a cylindrical-bodied needle with a conical point. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP size 2/0 (metric EP 3) and two grooved strands of 75 cm without coating, mounted on a Prime needle of ½ circle and taperpoint point of 20 mm (HR20 profile).
It is a common choice in ophthalmology, neurosurgery, general surgery and purchasing departments that value batch-to-batch consistency and full traceability of the Prime range. Sterile, ready-to-use product, presented in a box of 12 individual pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a synthetic polymer non-absorbable that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical phase of wound healing. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared to multifilament, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention, while the black colour ensures optimal contrast on the surgical field.
The 20 mm HR20 Prime needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The double-thread presentation 2×75 cm allows continuous sutures or multiple stitches without re-threading, optimising performance in high-consumption surgical programmes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P642HR2020.2 (suffix .2 = double strand 2×75 cm) |
| Reference Cahnos (SKU) | AMP642HR2020.2 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 2 × 75 cm (double strand, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 20 Prime (20 mm) |
| Configuration | 2 needles and 2 strands of 75 cm per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their established limits.
3.3. PREMISUT Prime family in nylon (½ circle needle, conical taperpoint point, black thread, double presentation)
| Needle profile | USP size | Thread | Reference |
| HR 20 Prime | 3/0 | 2 × 75 cm (black) | P642HR2030.2 / AMP642HR2030.2 |
| HR 20 Prime | 2/0 | 2 × 75 cm (black) | P642HR2020.2 / AMP642HR2020.2 (this product) |
| HR 26 Prime | 2/0 | 2 × 75 cm (black) | P642HR2620.2 / AMP642HR2620.2 |
| HR 26 Prime | 0 | 2 × 75 cm (black) | P642RHR2610.2 / AMP642HR2610.2 |
The same conical needle is offered in HR20 (shorter), HR26, HR30 and HR37 (longer travel) profiles and in USP sizes 4/0, 3/0, 2/0, 0 and 1 depending on the tissue plane to be sutured.
4. Equivalences and Cross-References
The reference P642HR2020.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR20 profile: ½ circle needle with 20 mm conical taperpoint point, USP size 2/0, black grooved thread of 75 cm in double-strand presentation) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (½ circle needle with 20 mm conical HR20 point, USP size 2/0, black, double thread 2×75 cm) with references from other houses; therefore, no closed cross-reference table is published here and matches must be treated as functional comparisons at category level, not interchangeable 1:1 without prior technical validation.
Homologous market families that must be reviewed property by property (material, size, curvature, point family, needle and strand length, number of strands, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / Johnson \u0026 Johnson MedTech), DAFILON® (B. Braun / Aesculap), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these houses have been verified in public sources for the exact HR20 20 mm configuration, USP 2/0, conical point and black 75 cm strand in double presentation; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HR20 Prime, USP 2/0, double 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the variant of the same needle and size in single-thread presentation is Ref. P642HR2020 (SKU AMP642HR2020). The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Tissue to be sutured: USP size 2/0 (metric EP 3) offers an excellent balance between strength and manageability for subcutaneous tissue, soft tissues with low-medium tension, low-tension fascia and ligatures, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 3/0 from the same family; for higher loads, USP 0 with the same Prime needle.
Needle length: the 20 mm HR20 profile is the ideal option for surgical fields with very limited travel (ophthalmology, minor surgery, paediatric surgery and neurosurgery). For medium-depth access, the HR26 (Ref. AMP642HR2620.2) and HR30 profiles from the same Prime range are available.
Double presentation: this reference provides 2 threads of 75 cm per pack, ideal for continuous sutures without re-threading or for distributing the material across two surgical fields. If the protocol only requires a single strand, the same needle and gauge are available in a 1 × 75 cm presentation (Ref. AMP642HR2020).
Prime vs. standard quality: the Prime range offers maximum sharpening precision and batch-to-batch consistency; if unit cost is a critical factor, the standard nylon range maintains the same dimensional specifications with standard sharpening performance.
Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642HR2020.2 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews