Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime (factory reference P642HR3010 · SKU Cahnos AMP642HR3010) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures requiring maximum sharpness precision and batch-to-batch consistency. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black colour, USP 0 gauge (metric EP 3.5) and 150 cm of grooved uncoated thread, mounted on a Prime ½-circle needle with cylindrical body and 30 mm taperpoint conical point.
It is a common choice in ophthalmology, neurosurgery, general surgery departments and in purchasing and tendering centres that need a permanent thread with high performance, predictable clinical behaviour and complete batch traceability. Sterile, ready-to-use product, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. As an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast on the operative field.
The 30 mm HR30 Prime needle features a ½-circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The Prime quality ensures more consistent sharpening and more predictable penetration at each stitch. The 150 cm of thread provide sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P642HR3010 |
| Reference Cahnos (SKU) | AMP642HR3010 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 0 (metric EP 3.5), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 150 cm |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 30 Prime (30 mm) |
| Configuration | 1 needle per unit, 1 strand of 150 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Storage | Below 30 °C, away from moisture and direct sunlight |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. Family PREMISUT HR30 Prime (needle ½ circle of 30 mm, conical taperpoint, black thread)
| Needle profile | USP size | Thread | Reference |
| HR 30 Prime | 1 | 1 × 75 cm (black) | P642HR3001 / AMP642HR3001 |
| HR 30 Prime | 1 | 2 × 75 cm (black, double thread) | P642HR3001.2 / AMP642HR3001.2 |
| HR 30 Prime | 0 | 1 × 150 cm (black, this product) | P642HR3010 / AMP642HR3010 |
| HR 30 Prime | 0 | 2 × 75 cm (black, double thread) | P642HR3010.2 / AMP642HR3010.2 |
| HR 30 Prime | 2/0 | 1 × 75 cm (black) | P642HR3020 / AMP642HR3020 |
| HR 30 Prime | 0 | 150 cm with loop (black) | P645HR30L10 / AMP645HR30L10 |
The same HR30 conical needle is available in other gauges (USP 1, 2/0) and in shorter (HR20, HR26) or longer (HR35, HR37, HR40, HR50) needle profiles depending on the surgical field reach.
4. Equivalences and Cross-References
The reference P642HR3010 corresponds to the official nomenclature of the PREMISUT Prime range (HR30 profile: ½-circle taperpoint conical point needle of 30 mm, USP 0 gauge, 150 cm black grooved thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination of USP 0 + ½-circle taperpoint 30 mm needle + 150 cm black strand; therefore, the following matches are functional, category-level comparisons, contrasted against the official catalogue of the cited manufacturer, and must not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 0 (EP 3.5), blue thread 75 cm, HR30 needle of 30 mm (½ circle, round body, conical point) | C0930482 (verified in official catalogue B. Braun and GUDID/FDA) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 0 gauge (EP 3.5), ½-circle curvature, conical point family and needle size (HR30 of 30 mm, identical); they differ in strand colour (blue vs. black) and length (75 cm vs. 150 cm). Confirm IFU and CE/MDR classification before substituting. |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, USP 0, 150 cm with loop, CT needle of ½ circle conical tip (taperpoint) | W740G (verified in official Ethicon catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 0 gauge (EP 3.5), black colour, ½-circle curvature, conical point family and strand length (150 cm); they differ in needle size (CT of 48 mm vs. HR30 of 30 mm, outside the ±1 mm tolerance) and format (loop vs. straight strand). Confirm IFU and CE/MDR classification before substituting. |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 0 (EP 3.5), 150 cm HR30 with loop (½ circle, conical tip) | C0933490 (verified in official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 0 gauge (EP 3.5), ½-circle curvature, conical point family, needle size (HR30 of 30 mm) and length (150 cm); they differ in strand colour (blue vs. black) and format (loop vs. straight strand). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families of non-absorbable nylon monofilament that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these manufacturers have been verified in public sources for the exact configuration of HR30 30 mm, USP 0, conical point and 150 cm black strand; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table for this configuration; check in the technical data sheet or instructions for use (IFU) of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR30 Prime, USP 0, 150 cm black strand) is only fully safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: USP 0 gauge (EP 3.5) offers an excellent balance between tensile strength and low tissue trauma, ideal for subcutaneous tissue, soft tissues, low-tension fasciae and ligatures, always with a taper-point needle to minimise tissue damage. For finer planes, consider USP 2/0 from the same HR30 Prime family (Ref. AMP642HR3020); for higher tension, USP 1 (Ref. AMP642HR3001 or double version AMP642HR3001.2).
Double-thread presentation: if the protocol requires two strands for continuous sutures without re-threading or to distribute the material across two surgical fields, the same needle and gauge are available in double thread 2 × 75 cm (Ref. AMP642HR3010.2).
Needle length: the HR30 profile of 30 mm is the ideal option for surgical fields with a medium-to-short course (ophthalmology, minor surgery, microsurgery). For deeper access, the HR37 (Ref. AMP642HR3710), HR40 (Ref. AMP642HR4010) and HR50 (series 643) profiles are available with the same taper-point family.
Loop format: for long continuous sutures without re-threading, the same HR30 Prime geometry in USP 0 gauge is available in a 150 cm loop (Ref. AMP645HR30L10).
Prime vs. standard quality: the Prime range provides maximum sharpening consistency batch to batch; if the cost per unit is a critical factor, the standard range maintains the same dimensional specifications with standard sharpening performance.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642HR3010 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews