Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 1/2 Cylindrical HR30mm Loop USP 0 Black (factory ref. P645HR30L10 · SKU AMP645HR30L10) is Cahnos’s premium reference within non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread, mounted on a cylindrical-bodied needle with a conical point.
It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP 0 gauge (metric EP 3.5) and 150 cm of grooved, uncoated thread in a loop presentation, with a Prime needle of ½ circle and taperpoint tip of 30 mm (HR30 profile). It is a common choice in ophthalmology, neurosurgery, general surgery and purchasing departments that value batch-to-batch consistency and full traceability of the Prime range. Sterile, ready-to-use product, supplied in a box of 12 units.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared to multifilaments, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast on the field.
The 30 mm HR30 Prime needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The Prime quality guarantees more consistent sharpening and more predictable penetration in each stitch. The loop format of 150 cm allows long continuous sutures or multiple stitches without re-threading, optimising performance in high-consumption surgical programmes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P645HR30L10 |
| Reference Cahnos (SKU) | AMP645HR30L10 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 0 (metric EP 3.5), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 150 cm in loop format |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 30 Prime (30 mm) |
| Configuration | 1 needle per unit, 1 thread of 150 cm with loop |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units in individual sterile sachets; batch traceability |
| Storage | Below 30 °C, away from moisture and direct sunlight |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopeia ranges for non-absorbable sutures, without extending their limits.
3.3. PREMISUT HR30 Prime family (½ circle 30 mm needle, taperpoint conical point, black thread with loop)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| HR 30 (standard, loop) | 1 | 1 × 150 cm (black, loop) | 645HR30L01 / AM645HR30L01 |
| HR 30 Prime (loop) | 0 | 1 × 150 cm (black, loop) | P645HR30L10 / AMP645HR30L10 (this product) |
| HR 35 (standard, loop) | 0 | 1 × 150 cm (black, loop) | 645HR35L10 / AM645HR35L10 |
The same HR30 conical needle is available in other gauges of the 645 loop series and in longer needle profiles (HR35, HR37, HR40) for fields with greater reach.
4. Equivalences and Cross-References
The reference P645HR30L10 corresponds to the official nomenclature of the PREMISUT Prime range (HR30 profile: ½ circle needle with 30 mm taperpoint conical point, USP 0 gauge, black grooved thread of 150 cm in loop format) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination of USP 0 + ½ circle taperpoint needle of 30 mm + black 150 cm loop thread; the following match is a functional, category-level comparison, contrasted against the official catalogue of the cited manufacturer and against the GUDID/FDA regulatory database, and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 0 (EP 3.5), 150 cm, HR30 ½ circle needle, conical point, loop format | C0933490 (verified in official B. Braun catalogue and in GUDID/FDA, DI 04038653714124) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 0 gauge (EP 3.5), ½ circle curvature, conical point family (taperpoint), needle size (HR30 of 30 mm), thread length (150 cm) and loop format; only the thread colour differs (blue vs black). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families of non-absorbable nylon monofilament that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / J&J MedTech), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these manufacturers have been verified in public sources for the exact configuration of HR30 30 mm, USP 0, conical point and black 150 cm loop thread; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HR30 Prime, USP 0, 150 cm loop) is only fully safely interchangeable within the PREMISUT system itself. Consult the Cahnos technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: USP 0 gauge (metric EP 3.5) offers an excellent balance between strength and manageability for subcutaneous tissue, muscle planes, fasciae and soft tissues with medium tension, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 2/0 from the same family; for higher loads, USP 1 on the same HR30 needle with loop (Ref. 645HR30L01 · SKU AM645HR30L01, or in the Prime range Ref. P645HR30L01 · SKU AMP645HR30L01).
Needle length: the HR30 profile of 30 mm covers medium-depth accesses. For fields with greater reach, the same loop series offers the HR35 profile in USP 0 (Ref. 645HR35L10 · SKU AM645HR35L10, or Prime version P645HR35L10 · SKU AMP645HR35L10) and the HR37, HR40 and HR50 profiles of the range.
Loop format: the 150 cm loop allows long continuous sutures without re-threading, ideal for high-consumption surgical programmes and for distributing the material across two fields. If the protocol requires a single strand without a loop, the straight thread series 642 (75 cm) and 643 (90 cm) from the same Prime range are available, for example Ref. P642HR3010 (SKU AMP642HR3010) with the same HR30 needle in USP 0.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P645HR30L10 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.