We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Non-Absorbable NYLON Suture PREMISUT Prime · ½ Circle Cylindrical Needle Taperpoint Conical Point 35 mm (HR35) · USP 1 (EP 4) · Black Monofilament Thread with 150 cm Loop · Polyamide 6/6.6 · Box of 12 units (Ref. P645HR35L01 · SKU AMP645HR35L01)

16,59 €

Non-absorbable surgical suture of monofilament nylon (polyamide 6/6.6) from the PREMISUT Prime range, USP 1 gauge (metric EP 4), black fluted thread of 150 cm in loop format and uncoated. It mounts a Prime needle of ½ circle with cylindrical body and 35 mm taperpoint conical point (HR35 profile), ideal for soft tissue approximation, ligatures, ophthalmology and neurosurgery; it maintains tensile strength beyond three months and is sterilised by ethylene oxide. Presentation in a box of 12 individual sterile sachets with batch traceability. Factory ref. P645HR35L01 · SKU AMP645HR35L01.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP645HR35L01

Description

1. Commercial Introduction

The NYLON Suture PREMISUT Prime 1/2 Cylindrical HR35mm (Factory ref. P645HR35L01 · SKU AMP645HR35L01) is the premium reference from Cahnos among non-absorbable nylon sutures for procedures requiring precision, handling and predictable clinical behaviour. It combines a monofilament of polyamide 6 or 6.6, uncoated and in identifying black, with a Prime needle of ½ circle, cylindrical body and taperpoint conical point of 35 mm (HR35 profile), in a 150 cm presentation with loop, designed for wide surgical fields and continuous sutures.

It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tenders that value the batch-to-batch consistency of the Prime range. Sterile product, ready to use, presented in a box of 12 individual sachets with batch traceability.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually encapsulates and maintains high tensile strength for more than three months, comfortably covering the critical healing phase. Being a uncoated monofilament, the strand slides easily through tissues, reduces the wick effect and bacterial drag compared to multifilaments, and minimises the inflammatory reaction. The grooved surface finish improves knot retention and handling, while the black colour ensures optimal contrast on the surgical field.

The HR35 Prime 35 mm needle features a ½ circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues separating the fibres without cutting them, indicated for soft and well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The 150 cm loop format provides the maximum strand length per package, ideal for continuous sutures, ligatures and deep fields without the need to re-attach the needle. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT Prime (premium range, enhanced penetration needle)
Factory reference P645HR35L01
Reference Cahnos (SKU) AMP645HR35L01
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament with grooved surface
Coating None
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 1 (EP metric 4), conforming to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.40 – 0.499 mm
Thread length 150 cm with loop
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Conical / cylindrical (Taperpoint), grooved
Needle size HR 35 Prime (35 mm)
Configuration 1 needle per unit, thread with 150 cm loop
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 sterile individual sachets; batch traceability
Storage Below 30 °C, away from moisture and direct sunlight
Regulatory standard Complies with USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm
1 (this product) 4 0.40 – 0.499 mm
2 5 0.45 – 0.499 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its limits.

3.3. PREMISUT HR35 loop family (½ circle 35 mm needle, taperpoint conical point, black thread with 150 cm loop)

Needle profile USP size Thread Reference
HR 35 (standard) 1 1 × 150 cm with loop (black) 645HR35L01 / AM645HR35L01
HR 35 (standard) 0 1 × 150 cm with loop (black) 645HR35L10 / AM645HR35L10
HR 35 Prime (this product) 1 1 × 150 cm with loop (black) P645HR35L01 / AMP645HR35L01

The same HR35 conical needle is available in shorter profiles (HR26, HR30) or longer ones (HR37, HR40, HR50) and in thread presentations of 75 or 90 cm for procedures with shorter paths.

4. Equivalences and Cross-References

The reference P645HR35L01 corresponds to the official nomenclature of the PREMISUT Prime range (HR35 profile: ½ circle needle with taperpoint conical point of 35 mm, USP 1 gauge, black grooved thread of 150 cm with loop) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.

Black non-absorbable monofilament nylon is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no equivalence table validated by the manufacturer that crosses this reference with other brands for the exact combination USP 1 + ½ circle taperpoint needle of 35 mm + black strand with 150 cm loop; the following comparisons are functional, at category level, contrasted against the official catalogue and authorised distribution, and should not be treated as 1:1 interchangeable without prior technical validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) ETHILON® – black monofilament nylon, USP 1, 150 cm thread with loop, MH-1 needle of ½ circle taperpoint conical point of 35 mm W739 (verified in authorised Ethicon distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), USP 1 gauge (EP 4), black colour, length with loop (150 cm) and needle size (MH-1 of 35 mm, ½ circle taperpoint, within the tolerance of ±1 mm). Confirm IFU, commercial presentation and CE/MDR classification before substituting.
DemeTECH DemeLON – black monofilament nylon, USP 1, 150 cm (59 inches) in loop, ½ circle needle with cylindrical body (round bodied) of 35 mm NL560135BI0P (verified in official DemeTECH store and GUDID/FDA) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), USP 1 gauge, black colour, ½ circle curvature, conical point, needle size of 35 mm and 150 cm loop format. Confirm in the official IFU the monofilament structure of the supplied batch and the regulatory classification before substituting.
B. Braun (Aesculap) DAFILON® blue – uncoated monofilament polyamide, USP 1 (EP 4), 150 cm thread with loop, HR37S needle of ½ circle conical point of 37 mm B0935769 (verified in official B. Braun catalogue) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), USP 1 gauge (EP 4), ½ circle curvature, conical point family and length with loop (150 cm); they differ in strand colour (blue vs black) and needle size (HR37S of 37 mm vs HR35 of 35 mm, outside the tolerance of ±1 mm). Confirm IFU and CE/MDR classification before substituting.

Other homologous families of non-absorbable monofilament nylon that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: ETHILON® (Ethicon / J&J MedTech), DAFILON® (B. Braun / Aesculap), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these manufacturers have been verified in public sources for the exact HR35 configuration of 35 mm, USP 1, black and 150 cm with loop; they must be confirmed with the manufacturer before use in substitution or tendering.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. This needle geometry (HR35 Prime, USP 1, black thread with 150 cm loop) is only safely interchangeable within the PREMISUT system itself. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

  • Tissue to suture: the HR needle with conical point (cylindrical body) is indicated for lax, well-vascularised soft tissues, vascular planes, ligatures and precision approximation in ophthalmology and neurosurgery; for skin, mucous membranes and firm tissues, consider the reverse cutting profiles (DS/HS series) from the same PREMISUT range.
  • Gauge: USP 1 (metric EP 4) offers high tensile strength for tissues under medium-to-high tension; for finer planes, the same HR35 needle with loop is available in USP 0 (Ref. AMP645HR35L10 and AM645HR35L10).
  • Prime vs. standard presentation: the Prime range maintains the same needle geometry with an improved finish and superior penetration; if unit cost is a critical factor, the standard version with identical configuration is Ref. 645HR35L01 (SKU AM645HR35L01), a direct equivalent within the same manufacturer.
  • Needle length: the 35 mm HR35 profile covers medium-depth access; for smaller fields, the HR26 and HR30 families are available (e.g. AMP645HR30L01), and for longer reach, the HR40 and HR50 profiles (e.g. AMP645HR40L01 and AMP645HR50L01).
  • Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P645HR35L01 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
  • For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Product line

PREMISUT Prime

Manufacturer reference

P645HR35L01

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Structure

Monofilament with grooved surface

Coating

None

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 1 (metric EP 4)

Thread diameter

0.40 – 0.499 mm

Thread length

150 cm with loop

Needle shape

1/2 circle (½ circular), cylindrical body

Tip type

Conical (Taperpoint)

Needle size

HR 35 Prime (35 mm)

Configuration

1 needle per unit, 150 cm looped suture

Sterilisation

Ethylene oxide (EO) – sterile

Use

Single-use, sterile. Do not re-sterilise

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Presentation

Box of 12 sterile individual sachets

Regulatory standard

Complies with USP/EP Pharmacopoeia; CE marking (MDR)

Metric gauge (EP)

4

Medida de aguja

HR 35

Usp

1

Color

Black

Medida de hilo

150 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable NYLON Suture PREMISUT Prime · ½ Circle Cylindrical Needle Taperpoint Conical Point 35 mm (HR35) · USP 1 (EP 4) · Black Monofilament Thread with 150 cm Loop · Polyamide 6/6.6 · Box of 12 units (Ref. P645HR35L01 · SKU AMP645HR35L01)”

Your email address will not be published. Required fields are marked *