Description
1. Commercial Introduction
The NYLON SUTURE PREMISUT Prime 1/2 Cylindrical HR26 (factory ref. P642HR2601 · SKU Cahnos AMP642HR2601) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures requiring sharpness precision, smooth handling and predictable clinical performance. Each pack contains a monofilament of polyamide 6 or 6.6, uncoated and in identifying black, mounted on a ½ circle needle with cylindrical body and grooved conical point (taperpoint) of 26 mm, USP gauge 1 (metric EP 4) and a single 75 cm strand.
It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tenders that require a permanent suture with full batch traceability and batch-to-batch consistency. Sterile, ready-to-use product, supplied in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical phase of wound healing. Being an uncoated monofilament, the strand slides easily through tissues, reduces the wick effect and bacterial wicking compared with multifilament sutures, and minimises the inflammatory reaction. The grooved finish of the thread improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast against the operative bed, especially in precision specialties.
The 26 mm HR26 Prime needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through soft tissues by separating the fibres without cutting them, making it especially suitable for fascia, peritoneum, muscle, conjunctiva and other soft, well-vascularised tissues where minimising trauma is sought. Prime quality ensures consistent sharpness and predictable penetration at every stitch. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P642HR2601 |
| Reference Cahnos (SKU) | AMP642HR2601 |
| Material | Nylon (polyamide 6 or 6.6), uncoated monofilament |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support > 3 months |
| Gauge | USP 1 / metric EP 4 (conforming to USP and European Pharmacopoeia) |
| Approximate thread diameter | 0.40 – 0.499 mm (USP range for non-absorbable synthetic suture) |
| Colour | Black (also available in blue in other references) |
| Needle | ½ circle, cylindrical body, taperpoint |
| Needle size | 26 mm (HR26 Prime) |
| Thread length | 75 cm (1 strand) |
| Configuration | 1 swaged needle / 1 thread per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. NYLON PREMISUT Prime 1/2 Cylindrical HR26 mm family (factory reference table)
| Needle size | USP | EP | Colour | Suture length | Reference |
| HR26 prime | 4/0 | 1.5 | Black | 75 cm | P642HR2640 |
| HR26 prime | 3/0 | 2 | Black | 75 cm | P642HR2630 |
| HR26 prime | 2/0 | 3 | Black | 75 cm | P642HR2620 |
| HR26 prime | 0 | 3.5 | Black | 75 cm | P642HR2610 |
| HR26 prime | 1 | 4 | Black | 75 cm | P642HR2601 (this product) |
| HR26 prime | 3/0 | 2 | Black | 2×75 cm | P642RHR2630.2 |
| HR26 prime | 2/0 | 3 | Black | 2×75 cm | P642RHR2620.2 |
| HR26 prime | 0 | 3.5 | Black | 2×75 cm | P642RHR2610.2 |
| HR26 prime | 1 | 4 | Black | 2×75 cm | P642RHR2601.2 |
The 642 series corresponds to 75 cm thread; the 645 series, to 150 cm thread with loop; the 643 series, to 90 cm thread without loop. The same HR26 conical needle is available in other gauges (USP 4/0, 3/0, 2/0 and 0) and this family continues in shorter needle profiles (HR20) or longer ones (HR30, HR37, HR40) for procedures with shorter or longer travel.
4. Equivalences and Cross-References
The reference P642HR2601 corresponds to the official nomenclature of the PREMISUT Prime range (HR26 profile: ½ circle needle with 26 mm taperpoint conical point, USP gauge 1, black grooved 75 cm thread) and Cahnos markets it without altering characters: no digit should be added, removed or rearranged when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table that cross-references this specific configuration (½ circle HR26 conical-point needle of 26 mm, USP gauge 1, black, 75 cm strand) with references from other manufacturers; checks carried out against official catalogues and regulatory databases (GUDID/FDA) have not confirmed a code from another brand that matches at the same time in material, USP gauge 1, ½ circle curvature, conical-point family and 26 mm needle size, so no closed cross-reference row is published.
Verified functional comparisons (outside geometric tolerance, not listed in table):
- B. Braun – Dafilon®(polyamide 6/6.6, uncoated monofilament): verified in the official B. Braun catalogue the configuration Dafilon Blue USP 1 (EP 4), 75 cm, with 30 mm HR30 conical needle (ref. C0930490). Material, USP gauge 1, thread length and conical-point family match, but the 30 mm needle falls outside the ±1 mm tolerance with respect to the 26 mm HR26 of our reference, so it is not interchangeable 1:1 nor listed in the table.
- Atramat (Internacional Farmacéutica, S.A. de C.V.) – Nylon, R-26 needle line (½ circle, 26 mm conical point): verified in GUDID the black configurations R2641-75N (USP 0, EP 3.5) and R2643-75N (USP 3-0, EP 2). The USP 1 configuration with R-26 needle has not been located in official sources; pending confirmation with the manufacturer.
- Ethicon – Ethilon®: homologous family of black monofilament nylon; confirm reference and availability with the official distributor before any substitution.
Other homologous market families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / J&J MedTech), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures), SUPRAMID® (SMI) and Atramat. No code from these manufacturers has been found in public sources that reproduces the exact combination of 26 mm HR26 + USP 1 + black 75 cm strand, so no unverified cross-reference codes are published.
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. This needle geometry (HR26 Prime, USP 1, 75 cm thread) is only safely interchangeable within the PREMISUT system itself: the direct equivalent within the same manufacturer is the standard-range version with identical configuration and gauge (Ref. 642HR2601 · SKU AM642HR2601), and the double-thread variant is Ref. P642RHR2601.2 · SKU AMP642RHR2601.2. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Tissue to be sutured: USP gauge 1 (metric EP 4) offers an excellent combination of strength and handling for subcutaneous tissue, soft tissues under medium-to-high tension, fasciae and ligatures, always with a taper-point needle to minimise tissue damage. For finer planes, consider USP 0 (Ref. P642HR2610 · SKU AMP642HR2610), USP 2/0 (Ref. P642HR2620 · SKU AMP642HR2620) or USP 3/0 (Ref. P642HR2630 · SKU AMP642HR2630) with the same HR26 Prime needle.
Needle length: the 26 mm HR26 profile is the standard choice for surgical fields with a short working distance (ophthalmology, minor surgery, neurosurgery). For smaller fields, the HR20 profile is available, and for deeper access, the HR30, HR37 or HR40 profiles with the same taper-point family.
Double presentation: this reference includes 1 strand of 75 cm per pack. If the protocol requires two strands per unit, the same needle and gauge are available in a double presentation 2×75 cm (Ref. P642RHR2601.2 · SKU AMP642RHR2601.2), ideal for continuous sutures without re-threading or for sharing material between two surgical fields.
Prime vs. standard quality: the Prime range provides maximum sharpening precision and batch-to-batch consistency; if unit cost is a critical factor, the standard nylon range maintains the same dimensional specifications with standard sharpening performance (Ref. 642HR2601 · SKU AM642HR2601).
Colour: in ophthalmology, black suture is preferred for its contrast against the field; in plastic surgery or skin closure, blue may be accepted if the centre’s protocol allows it.
Sterility verification: product sterile by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P642HR2601 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews