Description
1. Commercial Introduction
The NYLON Suture PREMISUT 1/2 Cylindrical HR20 (factory ref. 642HR2040 · SKU AM642HR2040) is the standard reference in the PREMISUT range within non-absorbable nylon sutures for procedures requiring a permanent, manageable thread with predictable clinical behaviour. It combines a polyamide 6 or 6.6 monofilament in identifying black, USP 4/0 gauge (metric EP 1.5) and a 75 cm uncoated strand, mounted on a ½ circle needle with cylindrical body and 20 mm taperpoint conical tip (HR20 profile).
It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tenders that value batch-to-batch consistency and full traceability of suture material. Sterile, ready-to-use product, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical phase of healing. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilament, and minimises the inflammatory reaction.
Its grooved finish improves knot grip and handling in the surgical field, while the black colour ensures optimal contrast on the operative field, especially in precision specialties. The 20 mm HR20 needle features a ½ circle curvature with cylindrical body and conical tip (taperpoint): the sharp tip without cutting edges penetrates soft tissues by separating the fibres without cutting them, making it especially suitable for fascia, peritoneum, muscle, conjunctiva and other soft, well-vascularised tissues where minimising trauma is sought. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT (standard range) |
| Factory reference | 642HR2040 |
| Reference Cahnos (SKU) | AM642HR2040 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 4/0 (metric 1.5 / EP 1.5), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.15 – 0.199 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 20 (20 mm) |
| Configuration | 1 needle per suture; 1 suture of 75 cm per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its limits.
3.3. PREMISUT HR20 family (½ circle needle of 20 mm, taperpoint conical point, black suture of 75 cm)
| Needle size | USP | EP | Colour | Reference |
| HR 20 | 6/0 | 0.7 | Black | 642HR2060 |
| HR 20 | 5/0 | 1 | Black | 642HR2050 |
| HR 20 | 4/0 | 1.5 | Black | 642HR2040 (this product) |
| HR 20 | 3/0 | 2 | Black | 642HR2030 |
| HR 20 | 2/0 | 3 | Black | 642HR2020 |
The same conical HR20 needle is available in Prime version (Ref. P642HR2040, premium range) and in longer travel profiles (HR26, HR30, HR37 and HR40) depending on the plane to be sutured.
4. Equivalences and Cross-References
Reference 642HR2040 corresponds to the official nomenclature of the PREMISUT range (HR20 profile: ½ circle needle with 20 mm taperpoint conical tip, USP 4/0 gauge, 75 cm grooved black thread) and Cahnos markets it without altering characters: no digit should be added, removed or rearranged when ordering or tendering.
Non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table that cross-references this specific configuration (HR20 of 20 mm, USP 4/0, conical tip, 75 cm black strand) with references from other houses; the following matches are functional comparisons at category level, contrasted against the official B. Braun catalogue, and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, blue 75 cm thread, HR26 needle (½ circle, round body, conical tip) | C0930423 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (uncoated polyamide 6/6.6), thread length (75 cm), ½ circle curvature and conical tip family; they differ in gauge (USP 2/0, EP 3, versus 4/0, EP 1.5), needle size (HR26 of 26 mm versus HR20 of 20 mm) and colour (blue versus black). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families of non-absorbable nylon monofilament that should be reviewed property by property (material, gauge, curvature, tip family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / J&J MedTech), DAFILON® (B. Braun / Aesculap), MONOSOF™ and DERMALON™ (Medtronic / Covidien), DEMELON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures), SUPRAMID® (SMI) and ATRAMAT® NYLON (Internacional Farmacéutica). No codes from these houses have been verified in public sources for the exact HR20 of 20 mm, USP 4/0, conical tip and 75 cm black strand configuration; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table; consult the technical department before using in tendering. This needle geometry (HR20, USP 4/0, 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the Prime variant of identical configuration (Ref. P642HR2040 · SKU AMP642HR2040) is the direct equivalent within the same manufacturer. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Tissue to suture: the USP 4/0 gauge (metric EP 1.5) offers great manageability and low reactivity for fine, well-vascularised planes: approximation of soft tissues, ligatures, ophthalmology, microsurgery and neurosurgery, always with a conical tip needle to minimise tissue damage. For higher tension planes, consider USP 3/0 (Ref. AM642HR2030), USP 2/0 (Ref. AM642HR2020) or USP 0 from the same family.
Needle length: the 20 mm HR20 profile is the ideal option for surgical fields with very limited travel (ophthalmology, minor surgery, paediatric surgery and neurosurgery). For medium-depth access, the HR26 (Ref. AM642HR2640), HR30, HR37 and HR40 profiles are available with the same conical tip family.
Alternative needle point: if the protocol requires a reverse cutting needle for skin or mucous membranes, the same gauge and length is available in the HS26 family, always with prior validation of the technical data sheet.
Prime quality: if the procedure demands maximum sharpening precision and batch-to-batch consistency, the PREMISUT Prime range offers the same geometry and gauge (Ref. P642HR2040 · SKU AMP642HR2040), a direct equivalent within the same manufacturer.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference 642HR2040 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews