We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Polyester suture Premisut Prime 1/2 circle, cylindrical body trocar point (TAPERCUT) 2xHRT26 mm, USP 2/0, green, 90 cm, double needle

Original price was: 103,74 €.Current price is: 65,20 €.

Non-absorbable surgical polyester suture Premisut Prime, braided multifilament coated with silicone, USP gauge 2/0 (EP 3), green colour and 90 cm of thread. Double needle configuration ½ circle, cylindrical body and trocar point TAPERCUT of 26 mm (2xHRT26), ideal for approximation and ligation of soft tissues, ophthalmology and neurosurgery. Provides tissue support for more than three months and is sterilised by ethylene oxide. Presentation in a box of 12 units, ref. AMP853HRT2620-2.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP853HRT2620-2

Description

1. Introduction

The polyester suture Premisut Prime in ½ circle configuration, cylindrical body and trocar point (TAPERCUT) of 26 mm is the choice of surgical departments seeking a high-performance non-absorbable thread, smooth handling and predictable tissue behaviour. Presented in USP gauge 2/0, green colour and 90 cm length, it allows professionals to unify criteria in procedures for approximation and ligation of soft tissues, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block.

2. Technical explanation

The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone, which improves sliding through tissue, facilitates knot descent and reduces tissue trauma. Being non-absorbable, it does not degrade by the enzymatic action of the body: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.

The ½ circle needle allows suturing in wide spaces with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT26) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time.

3. Technical Specifications

Material Braided multifilament polyester (polyethylene terephthalate)
Coating Silicone (polyester – polyethylene)
Suture type Non-absorbable, synthetic coated multifilament
Gauge USP 2/0 (EP 3)
Thread length 90 cm
Needle shape 1/2 circle
Tip type Cylindrical body with trocar point (TAPERCUT)
Needle configuration and size Double needle 2xHRT26 (Premilloy stainless steel), 26 mm
Colour Green
Behaviour No absorption; gradual encapsulation; tissue support exceeding 3 months
Tensile strength Permanent; exceeds USP and EP requirements
Sterilisation Ethylene oxide (EO)
Presentation Box of 12 units
Minimum order 10 boxes
Shelf life 5 years
Regulatory standard Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Reference AMP853HRT2620-2 (Atlas Medical – Premisut Prime)

4. Equivalences and Cross-References

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm P853HRT2620-2 / AMP853HRT2620-2 Reference analysed / direct equivalent Same family, measurements and material; the official factory code is AMP853HRT2620-2 and P853HRT2620-2 is the distributor’s commercial simplification.
Atlas Medical (Premisut) Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm (standard range) AM853HRT2620-2 Family equivalence Same geometry, gauge and length; standard range without Prime finish. Not interchangeable 1:1 without prior validation.
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm AMP853HRT2620.4-2 Family equivalence Same needle and gauge; multipack of 4 threads of 90 cm. Not interchangeable 1:1 in presentation.
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm with PTFE pledget 6x3x1.5 mm AMP853HRT2620PL6-2 Family equivalence Same configuration with PTFE pledget to increase the support surface of the stitch. Not interchangeable 1:1.
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT26, 3/0 green, 90 cm AMP853HRT2630-2 Family equivalence Same needle and geometry; finer gauge 3/0. Not interchangeable 1:1.
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT26, USP 0 green, 90 cm AMP853HRT2610-2 Family equivalence Same needle and geometry; larger gauge USP 0. Not interchangeable 1:1.
Atlas Medical (Premisut PRIME) Polyester 1/2 trocar 2xHRT36, 2/0 green, 90 cm AMP853HRT3620 Family equivalence Same configuration, gauge and length; 36 mm needle instead of 26 mm. Not interchangeable 1:1.
B. Braun Dagrofil (braided polyester) C0849383 (2/0 EP 3, 90 cm, double needle HRT26, green) Comparable by category, not interchangeable 1:1 Same gauge EP 3, green thread of 90 cm and double needle HRT26; Dagrofil is supplied without coating compared to the silicone coating of Premisut. Verify availability and local regulations.
Ethicon (Johnson & Johnson MedTech) Ethibond Excel (polyester) Consult official catalogue Comparable by category, not interchangeable 1:1 Non-absorbable coated polyester multifilament with similar indications; verify needle geometry (1/2 tapercut 26 mm), double needle configuration and USP/EP gauge before substituting.

There is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or substitution of references.

5. Selection tips and variants of interest

  • Dense or fibrous tissues: the 26 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression. For wider surgical fields, consider the 36 mm needle variant (AMP853HRT3620) and, for very restricted spaces, the 17 mm variant (AMP853HRT1720-2).
  • Ophthalmology and neurosurgery: the USP 2/0 gauge with double needle is ideal for continuous sutures and ligatures in delicate tissues; the green colour facilitates visibility of the thread on the surgical field.
  • Protocols with stitch reinforcement: if the procedure requires increasing the support surface of the thread, the variant with PTFE pledget 6x3x1.5 mm (AMP853HRT2620PL6-2 or AMP853HRT2620.4PL6-2) is the natural alternative.
  • Centralised purchasing: for high consumption, consider the multipack presentations of 4 x 90 cm (AMP853HRT2620.4-2) and take into account the minimum order of 10 boxes of this reference.
  • Alternative gauges: for finer tissues, the 3/0 (AMP853HRT2630-2) is available and for greater mechanical resistance the USP 0 (AMP853HRT2610-2), both with the same 2xHRT26 needle.
  • Before changing brand: always check needle angle (1/2), size (26 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material and coating in the technical data sheet of the alternative manufacturer.
  • Storage: sterile product by ethylene oxide with a shelf life of 5 years; respect the storage conditions and the expiry date of the packaging.

Additional information

Material

Braided multifilament polyester (polyethylene terephthalate)

Coating

Silicone (polyester – polyethylene)

Absorbability

Non-absorbable

Gauge

USP 2/0 (EP 3)

Needle type

Cylindrical trocar point (Tapercut)

Needle configuration

Double needle (2xHRT26)

Needle size

26 mm

Needle material

Stainless steel Premilloy

Tissue support

More than 3 months

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Minimum order

10 boxes

Shelf life

5 years

Regulatory standard

Regulation (EU) 2017/745 (MDR)

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Manufacturer reference

AMP853HRT2620-2 (Atlas Medical – Premisut Prime)

Medida de aguja

2xHRT 26 prime

Usp

2/0

Color

Green

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Reviews