Description
1. Commercial Introduction
The NYLON suture PREMISUT 1/2 Circle Triangular Reverse Cutting HS26 is one of the most versatile configurations in the Cahnos catalogue of non-absorbable sutures for B2B supply: operating theatres, purchasing centres, general and specialist surgery departments, ophthalmology clinics and neurosurgery units. It combines a nylon monofilament (polyamide 6 / 6.6) with predictable clinical behaviour, high-visibility black colour and an uncoated grooved strand, mounted on a ½ circle needle with a 26 mm reverse cutting triangular point (HS26 profile). Sterile, ready-to-use product with full batch traceability, designed for hospital replenishment, tenders and volume contracts. Price per box of 12 units in individual sterile sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a synthetic polymer non-absorbable that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament with a grooved finish, the strand slides easily through tissues, reduces the saw effect, minimises bacterial adherence compared with multifilaments and promotes a firm, stable knot with excellent retention.
The HS26 needle of 26 mm has a ½ circle curvature with a reverse cutting triangular point: the cutting edge cuts away from the wound, preserving the skin edge and preventing the cut from widening at the puncture bed. The grooved body of the needle improves the grip of the needle holder and the transmission of rotation, with a clean entry hole and a quality cosmetic result. This half-curve geometry is the usual reference in ophthalmology, neurosurgery, skin and mucous membranes, where maximum control of the entry point and tissue approximation is required.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | 642HS2630 |
| Reference Cahnos (SKU) | AM642HS2630 |
| Brand / Quality | PREMISUT (standard range) |
| Thread material | Nylon monofilament (polyamide 6 / 6.6), uncoated |
| Thread structure | Monofilament, grooved finish |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (metric 2 / EP 2), conforming to USP gauges and European Pharmacopoeia |
| Strand diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (1 needle per suture) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circle), fluted body |
| Tip type | Reverse cutting triangular (Reverse Cutting), triangular body and point |
| Needle size | HS 26 (26 mm), 1 needle per suture |
| Swaged | 1 needle per unit |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits. Minimal tissue reaction, excellent tensile strength, secure knot and fully predictable behaviour as there is no polymer degradation in the body.
3.3. PREMISUT HS26 family (½ circle needle, 26 mm, reverse cutting triangular point, black thread)
| Needle profile | USP size | Thread | Factory reference | SKU Cahnos |
|---|---|---|---|---|
| HS 26 (standard) | 2/0 | 1 × 75 cm (black) | 642HS2620 | AM642HS2620 |
| HS 26 (standard) | 3/0 | 1 × 75 cm (black) | 642HS2630 | AM642HS2630 (this product) |
| HS 26 Prime | 2/0 | 1 × 75 cm (black) | P642HS2620 | AMP642HS2620 |
| HS 26 Prime | 3/0 | 1 × 75 cm (black) | P642HS2630 | AMP642HS2630 |
| HS 26 Prime | 2/0 | 2 × 75 cm (black, double thread) | P642HS2620.2 | AMP642HS2620.2 |
4. Equivalences and Cross-References
Reference 642HS2630 corresponds to the official nomenclature of the PREMISUT range (HS26 profile: ½ circle needle with 26 mm reverse cutting triangular point, USP 3/0 gauge, black grooved thread of 75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or rearranged when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (HS26 ½ circle needle of 26 mm, USP 3/0, black, 75 cm) with references from other brands; the following matches are functional comparisons verified against official catalogues, the manufacturer’s official store, GUDID/FDA and authorised distribution, and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| DemeTECH | DemeLON® – black nylon monofilament, USP 3/0, 75 cm, DCP-2 needle of ½ circle reverse cutting, 26 mm | NL263026B4P (verified in GUDID/FDA and official DemeTECH catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide/nylon 6), USP 3/0 gauge, black colour, thread length (75 cm), ½ circle curvature, needle size (26 mm) and reverse cutting point; they differ in the commercial needle profile (DCP-2 vs HS26), the manufacturer and the presentation. Confirm IFU and CE/MDR marking before substituting. |
| B. Braun (Aesculap) | DAFILON® blue – uncoated polyamide monofilament, USP 3/0 (EP 2), 75 cm, HS26 needle of 26 mm (½ circle, reverse cutting body) | C0935963 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 3/0 gauge (EP 2), thread length (75 cm), ½ circle curvature, reverse cutting point family and needle size (26 mm); they differ in the colour of the strand (blue vs black). Confirm IFU and CE/MDR classification before substituting. |
| Medtronic (Covidien) | MONOSOF™ – black nylon monofilament, USP 3/0, 75 cm, C-16 needle of ⅜ circle reverse cutting of 30 mm | SN-671 (verified in official Medtronic datasheet and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide/nylon), USP 3/0 gauge, black colour and thread length (75 cm); they differ in needle curvature (⅜ vs ½ circle) and needle size (30 mm vs 26 mm). Confirm IFU and CE/MDR classification before substituting. |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, USP 3/0, 75 cm, PS reverse cutting needle (⅜ circle) | W1685BH (verified in authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), USP 3/0 gauge, black colour and thread length (75 cm); they differ in needle curvature (⅜ vs ½ circle) and point profile. Confirm IFU and CE/MDR classification before substituting. |
Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: ETHILON® (Ethicon/J&J MedTech), MONOSOF™ and DERMALON™ (Medtronic), DAFILON® (B. Braun), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner) and LUXAMID® (LuxSutures). The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. This needle geometry (HS26, USP 3/0, 75 cm) is only safely interchangeable within the PREMISUT system itself: the direct equivalent within the same manufacturer is the Prime version with identical geometry and gauge (Ref. P642HS2630, SKU AMP642HS2630).
5. Selection tips and variants of interest
Tissue to suture: the USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and medium-tension ligatures. The HS26 reverse cutting needle penetrates firm, non-distensible tissues without tearing the puncture bed, being especially indicated in ophthalmology, neurosurgery and precision ligatures.
Alternative gauge: if the protocol requires greater robustness for fasciae or higher loads, the same HS26 needle is available in USP 2/0 (SKU AM642HS2620 and Prime version AMP642HS2620). For finer planes, consider gauges 4/0 or lower from the same nylon family.
Prime quality: if the procedure requires maximum sharpening consistency batch to batch, the same geometry and gauge are available in the PREMISUT Prime range (Ref. P642HS2630, SKU AMP642HS2630), a direct equivalent within the same manufacturer.
Alternative curvatures and tips: for techniques requiring less curvature, the DS26 family (⅜ circle, reverse cutting, 26 mm) is available in SKU AM642DS2630 and AMP642DS2630; for lax or vascular tissues, the same ½ circle needle in a cylindrical taper-point version (HR26, SKU AMP642HR2630) avoids cutting the tissue.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference 642HS2630 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
B2B conditions: for volume hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.