Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 1/2 Circle Reverse Cutting Triangular HS26 (Ref. P642HS2630) is one of the most versatile configurations in the non-absorbable suture catalogue from Cahnos for B2B supply: operating theatres, purchasing centres, general and specialist surgery services, ophthalmology clinics and neurosurgery units. It combines a nylon monofilament (polyamide 6 or 6.6) with predictable clinical behaviour, high-visibility black colour and an uncoated grooved strand, mounted on a ½ circle needle with a 26 mm reverse cutting triangular point (HS26 Prime profile). Sterile, ready-to-use product with full batch traceability, designed for hospital replenishment, tenders and volume contracts. Price per box of 12 units in individual sterile sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament with a grooved finish, the strand slides easily through tissues, reduces the saw effect and bacterial adherence compared with multifilaments, minimises the inflammatory reaction and promotes a firm, stable knot with excellent knot retention.
The 26 mm HS26 Prime needle features a ½ circle curvature with a reverse cutting triangular point: the cutting edge is concentrated on the convex face of the arc and cuts outward from the wound, preventing tearing of the skin edge and facilitating passage through firm, non-distensible tissues. The grooved body improves needle holder grip and torque transmission, with a clean entry hole and a quality cosmetic result. This half-curve geometry is the standard reference in ophthalmology and neurosurgery, where maximum control of the entry point and tissue approximation is required.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P642HS2630 |
| Reference Cahnos (SKU) | AMP642HS2630 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 / 6.6), uncoated |
| Thread structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (metric 2 / EP 2), conforming to USP and European Pharmacopoeia gauges |
| Strand diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (1 needle per suture) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circle), fluted body |
| Tip type | Reverse cutting triangular (Reverse Cutting), triangular body and point |
| Needle size | HS26 Prime (26 mm), 1 needle per strand |
| Swaged | 1 needle per unit |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits. Minimal tissue reaction, excellent tensile strength, secure knot and fully predictable behaviour as there is no polymer degradation in the body.
3.3. PREMISUT Prime family with HS26 needle (½ circle, reverse cutting, black strand)
| Needle profile | USP size | Thread | Reference (SKU Cahnos) |
| HS26 Prime | 3/0 | 1 × 75 cm (black) | AMP642HS2630 (this product) |
| HS26 Prime | 2/0 | 1 × 75 cm (black) | AMP642HS2620 |
| HS26 standard | 3/0 | 1 × 75 cm (black) | AM642HS2630 |
4. Equivalences and Cross-References
The reference P642HS2630 corresponds to the official nomenclature of the PREMISUT Prime range (HS26 profile: ½ circle needle with 26 mm reverse cutting triangular point, USP 3/0 gauge, 75 cm black grooved strand) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table that cross-references this specific configuration (HS26 ½ circle needle, 26 mm, USP 3/0 gauge, black, 75 cm) with references from other houses. Comparable brands in the sector for this category include ETHILON® (Ethicon / Johnson & Johnson MedTech), MONOSOF™ (Medtronic / Covidien), DAFILON® (B. Braun), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner) and LUXAMID® (LuxSutures).
During verification, codes of close configuration have been found in official catalogues and authorised distribution — for example, ETHILON® EW320BG (3/0, 75 cm, black, 26 mm reverse cutting needle in ⅜ circle), MONOSOF™ SN-671 (3/0, 75 cm, black, C-16 needle in ⅜ circle) or DAFILON® C0935352 (3/0 EP 2, 75 cm, blue, DS24 needle in ⅜ circle) — but all differ from this product in needle curvature (⅜ vs ½ circle) and/or point profile, so they are considered comparable by category (not interchangeable 1:1) and are not presented as a direct equivalent. Before any substitution, the healthcare professional must check property by property in the manufacturer’s technical data sheet or instructions for use (IFU): material (polyamide 6 vs 6.6), strand diameter within the USP/EP range, curvature (½ circle), point family (reverse cutting), needle size (26 mm ± 1 mm), thread length (75 cm), colour, number of needles and CE/MDR regulatory classification. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. This needle geometry (HS26 Prime, USP 3/0, 75 cm black strand) is only safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
- Tissue to be sutured: the USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and medium-tension ligatures. The HS26 reverse cutting needle passes through firm, non-distensible tissues without tearing the puncture bed, being especially indicated in ophthalmology, neurosurgery and precision ligatures.
- Alternative gauge: if the protocol requires greater robustness for fasciae or higher loads, the same HS26 Prime needle is available in USP 2/0 (SKU AMP642HS2620). For finer planes, consider gauges 4/0 or lower from the same nylon family.
- Standard quality: if the budget requires an equivalent entry point with conventional sharpening, the same HS26 geometry, gauge and length is available in the standard PREMISUT range (SKU AM642HS2630), a direct equivalent within the same manufacturer; Prime quality adds batch-to-batch sharpening consistency for high-consumption programmes.
- Alternative curvatures and points: for techniques requiring less curvature, the DS26 family (⅜ circle, reverse cutting, 26 mm) is available in SKU AMP642DS2630 and AM642DS2630; for lax or vascular tissues, the same ½ circle needle in cylindrical taper-point version (HR26, SKU AMP642HR2630) avoids cutting the tissue.
- Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P642HS2630 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- B2B conditions: for volume hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.