Description
1. Commercial Introduction
The NYLON PREMISUT Suture 1/2 Triangular HS40 in USP 0 gauge is the reference in the standard range of non-absorbable sutures from Cahnos for procedures requiring a highly reliable permanent thread mounted on a medium-bodied reverse cutting needle. It combines an uncoated nylon monofilament (polyamide 6 or 6.6) in identifying black, USP 0 gauge (EP 3.5) and 75 cm of fluted thread, on a ½-circle needle with a 40 mm reverse cutting triangular point (HS40 profile).
It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tendering processes that require a high-performance permanent thread with predictable clinical behaviour and complete batch traceability. Sterile, ready-to-use product, supplied in a box of 12 units in individual sterile pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. As an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilament sutures, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling.
The 40 mm HS40 needle features a ½-circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed, facilitating passage through firm, poorly distensible tissues. USP 0 gauge (metric EP 3.5) provides medium-high strength for tissues under moderate tension, and the 75 cm thread offers sufficient length for continuous sutures or multiple stitches without re-threading. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT (standard line) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 1/2 circle (½ circular), grooved |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | HS 40 (40 mm) |
| Configuration | 1 needle per unit, grooved thread |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
| Storage | Below 30 °C, away from moisture and direct sunlight |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 642HS4010 |
| Reference Cahnos (SKU) | AM642HS4010 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3.0 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4.0 | 0.40 – 0.499 mm |
| 2 | 5.0 | 0.50 – 0.599 mm |
3.3. PREMISUT HS40 family (40 mm ½ circle needle, reverse cutting triangular point, black thread)
| Needle profile | USP size | Thread | Reference |
| HS 40 (standard) | 0 | 1 × 75 cm (black) | 642HS4010 / AM642HS4010 (this product) |
| HS 40 Prime | 0 | 1 × 75 cm (black) | P642HS4010 / AMP642HS4010 |
| HS 40 (standard) | 1 | 1 × 75 cm (black) | 642HS4001 / AM642HS4001 |
| HS 40 Prime | 1 | 1 × 75 cm (black) | P642HS4001 / AMP642HS4001 |
| HS 40 (standard) | 1 | 1 × 100 cm (black) | 647HS4001 / AM647HS4001 |
| HS 40 Prime | 1 | 1 × 100 cm (black) | P647HS4001 / AMP647HS4001 |
4. Equivalences and Cross-References
Reference 642HS4010 corresponds to the official nomenclature of the PREMISUT range (HS40 profile: ½-circle needle with 40 mm reverse cutting triangular point, USP 0 gauge, black fluted 75 cm thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination of USP 0 + ½-circle reverse cutting needle of 40 mm + black 75 cm strand; the following comparison is functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | DAFILON® Blue – uncoated polyamide monofilament, USP 0 (EP 3.5), 75 cm, 40 mm HS40 needle (½ circle, reverse cutting) | C0932760 (verified in GUDID/FDA and B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 0 gauge (EP 3.5), ½-circle curvature, HS40 needle profile (40 mm, reverse cutting), thread length (75 cm) and 1-needle mounting; the strand colour differs (blue versus black) and the presentation (box of 36 units from B. Braun). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution: ETHILON® (Ethicon – J&J MedTech), MONOSOF™ / DERMALON™ (Medtronic/Covidien), DemeLON™ (DemeTECH), LUXAMID® (LuxSutures) and SUPRAMID® (SMI / B. Braun). No codes from these manufacturers have been verified in public sources for the exact HS40 40 mm, USP 0 and black 75 cm strand configuration; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HS40, USP 0, 75 cm) is only safely interchangeable within the PREMISUT system itself (642HS4010 / AM642HS4010 and its direct equivalent in the Prime range P642HS4010 / AMP642HS4010).
5. Selection tips and variants of interest
Tissue to suture: USP 0 gauge (EP 3.5) offers medium-high strength for subcutaneous tissue, skin under moderate tension, fasciae and deep planes. The reverse cutting needle passes through dense tissues without tearing the puncture bed. For finer planes consider USP 2/0 (HS26) or USP 3/0 from the same family; for a larger gauge, USP 1 (642HS4001 / AM642HS4001).
Prime quality: if the procedure requires maximum sharpening precision and batch-to-batch consistency, the same geometry and gauge are available in the Prime range (Ref. P642HS4010, SKU AMP642HS4010), a direct equivalent within the same manufacturer compared with the standard range (642HS4010 / AM642HS4010).
Thread length: the 75 cm covers continuous sutures or several stitches without re-threading; if you need greater length, the same nylon range offers HS40 configurations in 100 cm (647HS4001 / AM647HS4001 and Prime version AMP647HS4001, both in USP 1).
Needle length: the 40 mm HS40 profile covers medium-depth access. For wider fields or deep planes, the 48 mm HS48 profile is available in USP 1 and 100 cm (647HS4801 / AM647HS4801); for ophthalmology and reduced fields, HS36 profiles (642HS3610 / AM642HS3610) or HS26.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep reference 642HS4010 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.





Reviews