Description
1. Introduction
The hypodermic needle Nipro 21G (0.8 x 16 mm), factory reference HN-2116-ET, is the trusted solution for injections that require precision, comfortable puncture and effective medication flow. Its lancet point with original silicone coating reduces penetration force and minimises patient discomfort, while FLOMAX thin-wall technology maximises internal flow while maintaining the same outer diameter. A sterile single-use product, manufactured by Nipro in accordance with international standards for hypodermic needles, designed for hospitals, clinics, health centres and home care.
2. Technical explanation of the device
The 21G gauge corresponds to an outer diameter of 0.8 mm and carries the green colour code according to ISO 6009:2016. With a cannula length of 16 mm (5/8″), the official Nipro technical data sheet classifies this reference for intramuscular injection; in clinical practice it is also used for moderate-flow intravenous punctures (common market use, not a manufacturer specification).
The cannula is made of SUS 304 stainless steel and features a lancet point with original silicone coating, which reduces tissue damage compared with conventional bevels. Its FLOMAX thin wall increases internal flow while maintaining the same outer diameter. The hub is Luer type (ISO 594), compatible with standard Luer hub syringes from the same Nipro range. Sterile, single-use product, manufactured in accordance with ISO 7864 (hypodermic needles), ISO 9626 (steel tubes) and ISO 6009 (colour coding).
3. Technical Specifications
The technical features are listed in the following table, prepared from the official Nipro technical data sheet for the hypodermic needle family:
| Parameter | Specification |
| Manufacturer reference | HN-2116-ET (SKU Cahnos: HN2116ET) |
| Gauge | 21G (0.8 mm outer diameter) |
| Cannula length | 16 mm (5/8″) |
| Colour code ISO 6009 | Green |
| Tip type | Lancet with original siliconisation |
| Wall technology | FLOMAX thin wall (maximum flow) |
| Cannula material | Stainless steel SUS 304 |
| Connection | Luer slip cone (ISO 594) |
| Clinical indication (according to Nipro data sheet) | Intramuscular injection |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile, non-reusable |
| Presentation | Box of 100 units |
| Reference standards | ISO 7864, ISO 9626, ISO 6009 |
4. Equivalences and Cross-References
The following table lists references from other manufacturers with the same 21G gauge (0.8 mm) and green colour code ISO 6009, verified against the official catalogue or technical data sheet of the corresponding manufacturer. They are classified as comparable by category: they match in gauge, material and length, but differ in bevel design, so they are not 1:1 interchangeable with the Nipro needle without validation of the unit’s protocol.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| BD (Becton Dickinson) | Microlance 3, 21G x 5/8″ (0.8 x 16 mm), green | 304434 | Comparable by category (not interchangeable 1:1) | Same size, thin wall and green colour code ISO 6009; polished and silicone-coated triple bevel point versus the Nipro lancet point. Code verified with authorised distributors; check the official technical data sheet before substituting. |
| Terumo | Agani™ (successor to Neolus), 21G x 5/8″ (0.8 x 16 mm), green | 8AN2116R1 | Comparable by category (not interchangeable 1:1) | Same size and ultra-sharp lancet point with silicone lubrication; it is the design closest to the Nipro lancet point. Code verified in distributor catalogue with manufacturer data sheet. |
| B. Braun | Sterican, 21G x 1″ (0.8 x 25 mm), green | 4657543B | Comparable by category (not interchangeable 1:1) | Same 21G gauge (0.8 mm) and green colour ISO 6009, but length of 25 mm versus 16 mm: it does not cover the same depth as the 16 mm reference. It is listed as a longer alternative for deeper routes. |
There is no equivalence table validated by the manufacturer (Nipro) for this reference; consult the technical department before use in tenders. Other brands with homologous families of 21G hypodermic needles (e.g. safety lines with needlestick protection) must be checked reference by reference against their official technical data sheet before any substitution.
5. Selection tips and variants of interest
Choose the 21G x 5/8″ (0.8 x 16 mm) needle when you need a medium gauge for moderate-flow injections and a short length that allows precise control of the puncture. For other needs, consider the variants of the same Nipro family:
| Reference | Size | Main indication (according to Nipro data sheet) |
| HN-2116-ET (this product) | 21G x 5/8″ (0.8 x 16 mm) | Intramuscular injection |
| HN-2125-ET | 21G x 1″ (0.8 x 25 mm) | Intravenous injection |
| HN-2138-ET | 21G x 1 1/2″ (0.8 x 40 mm) | Intramuscular injection |
| HN-2316-ET (SKU 0898079) | 23G x 5/8″ (0.6 x 16 mm) | Intravenous / intramuscular injection of small volume |
| HN-2516-ET (SKU 0898006) | 25G x 5/8″ (0.5 x 16 mm) | Subcutaneous injection |
| HN-2713-ET (SKU 0898010) | 27G x 1/2″ (0.4 x 13 mm) | Delicate subcutaneous / intradermal injection |
Always check the integrity of the sterile packaging before use, do not reuse the needle and dispose of it after puncture in an approved container for sharps waste, in accordance with biological risk prevention regulations.





Reviews
There are no reviews yet.