Description
1. Introduction
The Nipro 19G hypodermic needle (1.1 x 25 mm / 1″), manufacturer reference HN-1925-ET, is the trusted solution for intravenous injections and administration of medium-flow medication. Its original siliconised lancet point reduces penetration force and minimises patient discomfort, while FLOMAX thin-wall technology maximises the internal flow rate while maintaining the same outer diameter. A sterile, single-use product manufactured by Nipro in accordance with international standards for hypodermic needles, designed for hospitals, clinics, health centres and home care.
2. Technical explanation of the device
The 19G gauge corresponds to an outer diameter of 1.1 mm and carries the ivory colour code according to standard ISO 6009:2016. With a cannula length of 25 mm (1″), the official technical data sheet from Nipro classifies this reference for intravenous injection, being suitable for superficial or medium-depth venous access and for the administration of medium-to-high flow medications.
The cannula is made of SUS 304 stainless steel and features an original siliconised lancet point, which reduces tissue damage compared with conventional bevels. Its FLOMAX thin wall increases the internal flow rate while maintaining the same outer diameter. The hub is Luer type (ISO 594), compatible with standard Luer hub syringes from the same Nipro range. Sterile, single-use product manufactured in accordance with standards ISO 7864 (hypodermic needles), ISO 9626 (steel tubes) and ISO 6009 (colour coding).
3. Technical Specifications
The technical features are listed in the following table, prepared from the official technical data sheet of the Nipro hypodermic needle family:
| Parameter | Specification |
|---|---|
| Manufacturer reference | HN-1925-ET (SKU Cahnos: HN1925ET) |
| Gauge | 19G (1.1 mm outer diameter) |
| Cannula length | 25 mm (1″) |
| Colour code ISO 6009 | Ivory |
| Tip type | Lancet with original siliconisation |
| Wall technology | FLOMAX thin wall (maximum flow) |
| Cannula material | Stainless steel SUS 304 |
| Connection | Luer slip cone (ISO 594) |
| Clinical indication (according to Nipro data sheet) | Intravenous injection |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile, non-reusable |
| Presentation | Box of 100 units |
| Reference standards | ISO 7864, ISO 9626, ISO 6009 |
4. Equivalences and Cross-References
The following table lists references from other manufacturers with the same 19G gauge (1.1 mm) and 1″ (25 mm) length, verified against the official catalogue or technical data sheet of the corresponding manufacturer. They are classified as comparable by category: they match in gauge, length and colour code, but differ in bevel design, so they are not interchangeable 1:1 with the Nipro needle without validation of the unit’s protocol.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| BD (Becton Dickinson) | Microlance 3, 19G x 1″ (1.1 x 25 mm), ivory/cream | 301700 | Comparable by category (not interchangeable 1:1) | Same size, thin wall and colour code ISO 6009; polished and siliconised triple-bevel point compared with the Nipro lancet point. Code verified in technical data sheet and authorised distributors; check the official technical data sheet before substituting. |
| Terumo | Agani™ (successor to Neolus), 19G x 1″ (1.1 x 25 mm), ivory | AN*1925R1 (8AN1925R1) | Comparable by category (not interchangeable 1:1) | Same size and ultra-sharp lancet point with silicone lubrication; it is the design closest to the Nipro lancet point. Code verified in distributor catalogue with Terumo manufacturer data sheet. |
There is no equivalence table validated by the manufacturer (Nipro) for this reference; consult the technical department before use in tenders. The homologous family B. Braun Sterican covers the 19G gauge in lengths of 30, 40 and 50 mm within its standard programme (it does not offer 1″/25 mm), so any substitution with this brand must be cross-checked reference by reference against its official technical data sheet. Other brands with homologous families of 19G hypodermic needles (e.g. safety lines with needlestick protection) must be cross-checked in the same way before any substitution.
5. Selection tips and variants of interest
Choose the 19G x 1″ (1.1 x 25 mm) needle when you need medium-flow intravenous injection, administration of medium-viscosity medication or medium-depth venous access, combining a good flow rate (FLOMAX thin wall) with comfortable puncture for the patient. For other needs, consider the variants of the same Nipro family:
| Reference | Size | Main indication (according to Nipro data sheet) |
|---|---|---|
| HN-1925-ET (this product) | 19G x 1\” (1.1 x 25 mm) | Intravenous injection |
| HN-1932-ET | 19G x 1 1/4\” (1.1 x 30 mm) | Intravenous injection |
| HN-1938-ET | 19G x 1 1/2″ (1.1 x 40 mm) | Intravenous injection |
| HN-1832-ET (SKU HN1832ET) | 18G x 1 1/4\” (1.2 x 30 mm) | Transfer / slightly higher flow |
| HN-2025-ET | 20G x 1″ (0.9 x 25 mm) | Intravenous injection of smaller gauge |
| HN-2116-ET (SKU HN2116ET) | 21G x 5/8″ (0.8 x 16 mm) | Intramuscular injection |
Always check the integrity of the sterile packaging before use, do not reuse the needle and dispose of it after puncture in an approved sharps container, in accordance with biological risk prevention regulations.