We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Hypodermic needle Nipro 19G (1.1 x 25 mm / 1″) sterile – Ref. HN-1925-ET | Box of 100 units

6,95 €

Hypodermic needle Nipro 19G (1.1 x 25 mm / 1″) single-use, manufacturer reference HN-1925-ET (SKU Cahnos: HN1925ET). Original siliconised lancet point that minimises pain on puncture and FLOMAX thin-wall technology that maximises medication flow. Stainless steel cannula, Luer hub compatible with standard syringes and ivory-coloured hub according to ISO 6009. Sterilised by ethylene oxide and indicated by the manufacturer for intravenous injection. Presentation in a box of 100 units for hospitals, clinics and home care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
HN1925ET

Description

1. Introduction

The Nipro 19G hypodermic needle (1.1 x 25 mm / 1″), manufacturer reference HN-1925-ET, is the trusted solution for intravenous injections and administration of medium-flow medication. Its original siliconised lancet point reduces penetration force and minimises patient discomfort, while FLOMAX thin-wall technology maximises the internal flow rate while maintaining the same outer diameter. A sterile, single-use product manufactured by Nipro in accordance with international standards for hypodermic needles, designed for hospitals, clinics, health centres and home care.

2. Technical explanation of the device

The 19G gauge corresponds to an outer diameter of 1.1 mm and carries the ivory colour code according to standard ISO 6009:2016. With a cannula length of 25 mm (1″), the official technical data sheet from Nipro classifies this reference for intravenous injection, being suitable for superficial or medium-depth venous access and for the administration of medium-to-high flow medications.

The cannula is made of SUS 304 stainless steel and features an original siliconised lancet point, which reduces tissue damage compared with conventional bevels. Its FLOMAX thin wall increases the internal flow rate while maintaining the same outer diameter. The hub is Luer type (ISO 594), compatible with standard Luer hub syringes from the same Nipro range. Sterile, single-use product manufactured in accordance with standards ISO 7864 (hypodermic needles), ISO 9626 (steel tubes) and ISO 6009 (colour coding).

3. Technical Specifications

The technical features are listed in the following table, prepared from the official technical data sheet of the Nipro hypodermic needle family:

Parameter Specification
Manufacturer reference HN-1925-ET (SKU Cahnos: HN1925ET)
Gauge 19G (1.1 mm outer diameter)
Cannula length 25 mm (1″)
Colour code ISO 6009 Ivory
Tip type Lancet with original siliconisation
Wall technology FLOMAX thin wall (maximum flow)
Cannula material Stainless steel SUS 304
Connection Luer slip cone (ISO 594)
Clinical indication (according to Nipro data sheet) Intravenous injection
Sterilisation Ethylene oxide (EO)
Use Single-use, sterile, non-reusable
Presentation Box of 100 units
Reference standards ISO 7864, ISO 9626, ISO 6009

4. Equivalences and Cross-References

The following table lists references from other manufacturers with the same 19G gauge (1.1 mm) and 1″ (25 mm) length, verified against the official catalogue or technical data sheet of the corresponding manufacturer. They are classified as comparable by category: they match in gauge, length and colour code, but differ in bevel design, so they are not interchangeable 1:1 with the Nipro needle without validation of the unit’s protocol.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
BD (Becton Dickinson) Microlance 3, 19G x 1″ (1.1 x 25 mm), ivory/cream 301700 Comparable by category (not interchangeable 1:1) Same size, thin wall and colour code ISO 6009; polished and siliconised triple-bevel point compared with the Nipro lancet point. Code verified in technical data sheet and authorised distributors; check the official technical data sheet before substituting.
Terumo Agani™ (successor to Neolus), 19G x 1″ (1.1 x 25 mm), ivory AN*1925R1 (8AN1925R1) Comparable by category (not interchangeable 1:1) Same size and ultra-sharp lancet point with silicone lubrication; it is the design closest to the Nipro lancet point. Code verified in distributor catalogue with Terumo manufacturer data sheet.

There is no equivalence table validated by the manufacturer (Nipro) for this reference; consult the technical department before use in tenders. The homologous family B. Braun Sterican covers the 19G gauge in lengths of 30, 40 and 50 mm within its standard programme (it does not offer 1″/25 mm), so any substitution with this brand must be cross-checked reference by reference against its official technical data sheet. Other brands with homologous families of 19G hypodermic needles (e.g. safety lines with needlestick protection) must be cross-checked in the same way before any substitution.

5. Selection tips and variants of interest

Choose the 19G x 1″ (1.1 x 25 mm) needle when you need medium-flow intravenous injection, administration of medium-viscosity medication or medium-depth venous access, combining a good flow rate (FLOMAX thin wall) with comfortable puncture for the patient. For other needs, consider the variants of the same Nipro family:

Reference Size Main indication (according to Nipro data sheet)
HN-1925-ET (this product) 19G x 1\” (1.1 x 25 mm) Intravenous injection
HN-1932-ET 19G x 1 1/4\” (1.1 x 30 mm) Intravenous injection
HN-1938-ET 19G x 1 1/2″ (1.1 x 40 mm) Intravenous injection
HN-1832-ET (SKU HN1832ET) 18G x 1 1/4\” (1.2 x 30 mm) Transfer / slightly higher flow
HN-2025-ET 20G x 1″ (0.9 x 25 mm) Intravenous injection of smaller gauge
HN-2116-ET (SKU HN2116ET) 21G x 5/8″ (0.8 x 16 mm) Intramuscular injection

Always check the integrity of the sterile packaging before use, do not reuse the needle and dispose of it after puncture in an approved sharps container, in accordance with biological risk prevention regulations.

Additional information

Manufacturer reference

HN-1925-ET

Gauge

19G

Cannula length

25 mm (1")

Colour code ISO 6009

Ivory

Tip type

Lancet with original siliconisation

Wall technology

FLOMAX thin wall (maximum flow)

Cannula material

Stainless steel SUS 304

Connection

Luer slip cone (ISO 594)

Indication according to the nipro data sheet

Intravenous injection

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile, non-reusable

Presentation

Box of 100 units

Regulatory standard

ISO 7864, ISO 9626, ISO 6009

Diametro mm

11 mm

Reviews

There are no reviews yet.

Be the first to review “Hypodermic needle Nipro 19G (1.1 x 25 mm / 1″) sterile – Ref. HN-1925-ET | Box of 100 units”