Description
Autoclavable spare handle for Pentaled 12, 28 and 30E Light
1. Introduction
This autoclavable spare handle (ref. 30793) is the original replacement grip for the LED surgical lamps of the Pentaled 12, 28 and 30E Light series. Designed to replace the factory part when it wears out or reaches the limit of its sterilisation cycles, it allows the full functionality of the lamp to be restored in a few minutes and maintains optimal aseptic conditions in the surgical field.
2. Technical explanation of the equipment
The Pentaled surgical lamps incorporate a removable, sterilizable handle or grip with a dual function: allowing the light head to be oriented and focused during the procedure, and providing a gripping point that can be sterilised in an autoclave without damaging the equipment. In the Pentaled series, the LED modules are focused mechanically by turning the sterilizable handle, which also regulates the diameter of the light field. This spare part reproduces the original part exactly, so it maintains the fit, ergonomics and mechanical behaviour of the factory-fitted handle. As an autoclavable component, it withstands repeated cycles of moist-heat sterilisation, an essential requirement in operating theatres and care units where hygiene is a priority.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 30793 |
| SKU Cahnos | GM30793 |
| Sales unit | 1 pc |
| Device type | Replacement (spare part) |
| Compatibility | Surgical lamps Pentaled 12, 28 and 30E Light |
| Sterilisation | Autoclavable (suitable for autoclave sterilisation) |
| EAN | 8023279307931 |
4. Equivalences and Cross-References
This handle corresponds to factory reference 30793, marketed at Cahnos as GM30793. Within the same spare parts catalogue for LED lamps there are other autoclavable handles from the same family: ref. 30797 (spare part for Primaled and Saturno examination lamps) and ref. 30785 (spare part for Pentaled 30 up to serial number 12071). No validated equivalence table against other manufacturers is available for this part; it is always recommended to verify compatibility with the exact lamp model before replacing the handle.
5. Selection tips and variants of interest
Check the series of your lamp (Pentaled 12, 28 or 30E Light) to ensure the correct fit of this spare part. If your equipment is from the Pentaled 30 family with a serial number less than or equal to 12071, consider reference 30785; if your lamp is from the Primaled or Saturno examination series, the appropriate reference is 30797. Since autoclavable handles have a limited number of sterilisation cycles, it is recommended to keep a spare replacement available so as not to interrupt clinical activity. For equipment projects, compatibility queries or quotes, our technical-commercial team at Cahnos is at your disposal.







Reviews