Description
1. Introduction
Maintain the highest image quality in your endoscopy, microscopy and analysis equipment with the Cermax Y1964 300 W xenon lamp, manufactured by Excelitas Technologies (formerly PerkinElmer). It is the reference replacement for Pentax EPK-i processors and the Smith & Nephew 500XL light source, and stands out for offering a bright, intense and stable white light with excellent colour reproduction, essential in medical diagnostic, laboratory and precision industrial applications. A reliable and durable solution for hospital maintenance services, endoscopy fleets, R&D departments and optical fibre illumination systems.
2. Technical explanation
The Y1964 lamp uses short-arc xenon discharge technology: light is generated in a high-pressure electric arc that burns in xenon gas inside a ceramic body with a ceramic-metal seal, a design that is much safer, more compact and more stable than conventional quartz lamps. Its integrated parabolic reflector concentrates the beam into a very small focal point, optimising coupling to light guides and optical fibres with minimal losses. It operates on direct current at 300 W (range 275–325 W) with a nominal voltage of 14 V, delivers a flux of approximately 5500 lumens and a colour temperature of 5900 K, very close to daylight, with a continuous spectrum and excellent colour fidelity. Its average service life is 1000 hours and it is designed for instant on/off operation, with a minimum ignition voltage of 23 kV.
3. Technical Specifications
Validated technical features of the Cermax Y1964 lamp (Excelitas Series):
| Characteristic | Value |
|---|---|
| Type | High-power short-arc xenon lamp (discharge) |
| Brand / Series | Excelitas Technologies (Cermax series) |
| Model | Y1964 (equivalent Y1911 for Pentax) |
| Power | 300 W (range 275–325 W) |
| Voltage | 14 V DC nominal (range 12–15 V) |
| Amperage | 21 A (range 17–23 A) |
| Ignition voltage | Min. 23 kV |
| Luminous flux | Approx. 5500 lumens |
| Colour temperature | 5900 K (daylight white) |
| Radiant output | 75 W (4 W UV < 390 nm) |
| Optics | Parabolic reflector integrated in ceramic body |
| Shelf life | Long life: 1000 average hours under demanding conditions |
| Operation | Direct current, instant on/off |
| Presentation | Unit (ref. Cahnos 50021071) |
Applications:
- Endoscopy and laparoscopy (Pentax EPK-i processors and Smith & Nephew 500XL)
- Microscopy and spectroscopy
- Optical fibre illumination and projection systems
- High-demand medical and industrial applications
4. Equivalences and Cross-References
The Cermax Y1964 lamp is marketed under multiple codes depending on the manufacturer and distribution channel. The most common functional equivalents are:
| Code | Origin / Destination |
|---|---|
| Y1964 | Excelitas Cermax reference (general distribution) |
| Y1911 | Same lamp, coded for Pentax |
| ME300C-10F | Alternative manufacturer code |
| OL-X28 / L-X29 | Alternative distributor codes |
| ROL-28 / ROL-X28 | Replacement for Pentax EPK-i processors |
| CE-317LO/540 | Order code in European distribution |
It is the standard replacement lamp for the Pentax EPK-i 5000, EPK-i 5010, EPK-i 7000 and EPK-i 7010 video processors, as well as for the Smith & Nephew 500XL light source. Within the Cahnos catalogue, it coexists with other 300 W discharge lamps: the EXCELITAS Cermax PE300BFA (ref. 50003401), the EXCELITAS J2022 for Olympus CLV-190 (ref. 50014955) and the OSRAM XBO R 180W/45 C OFR (ref. 50002956 and 50002957), in addition to the 175 W Cermax PE175BFA (ref. 50003403) for lower-power applications.
5. Selection tips and variants of interest
Before replacing the lamp, note the hours recorded on the light source counter and carry out the preventive replacement when reaching approximately the recommended 1000 hours, to avoid drops in intensity during the procedure. Always handle the lamp with gloves or a clean, dry cloth: fingerprints on the glass window generate hot spots and drastically reduce service life. Work with the equipment switched off and cold, verify that the housing is free of dust and respect the connection polarity and the working range indicated by the manufacturer. If your application requires lower power, the 175 W Cermax PE175BFA (ref. 50003403) is the natural alternative; if you need the specific reference for Olympus CLV-180/190/290 towers, the EXCELITAS J2022 (ref. 50014955) guarantees the original MAJ-1817 mounting. For scheduled maintenance orders or large volumes, our technical-commercial team can advise you on identifying the exact replacement for your equipment fleet.