Heine XHL Xenon Halogen 2.5 V #056 Replacement Lamp for Mini 2000 and Minilux Otoscope | Ref. X-001.88.056

30,80 €

Original replacement lamp Heine XHL Xenon Halogen #056 2.5 V (Ref. X-001.88.056), manufactured in Germany by HEINE Optotechnik. Specific spare part for the Mini 2000 and Minilux otoscopes, it offers white, bright and stable light with the ideal colour temperature for precision ENT examinations. Its calibrated filament and the lenses integrated into the bulb guarantee a homogeneous beam, quick installation and a service life up to 50% longer than conventional bulbs.

International shipping. Import duties and taxes are payable by the recipient.

Reference
X00188105-LM

You will also find it in

Description

Introduction

Keep your otoscope always operational with the Heine XHL Xenon Halogen #056 2.5 V replacement lamp, an original spare part from HEINE Optotechnik manufactured in Germany. Specifically designed for the Mini 2000 and Minilux otoscopes, this bulb ensures white, bright and stable illumination: the precision and reliability required for ENT and general diagnostic examinations, avoiding interruptions in the consultation when it is most needed.

Technical explanation

The Heine #056 lamp belongs to the XHL Xenon series and combines xenon gas with halogen technology to achieve high luminous performance in a compact format. It operates at 2.5 V with a current consumption of 0.3 A and provides white, constant light with a balanced colour temperature, allowing faithful appreciation of tissue colour during otoscopy. Its precisely positioned filament and the lenses integrated into the bulb glass guarantee homogeneous light projection, quick installation and a firm seat in the instrument head, minimising downtime of the clinical equipment.

Technical specifications

Original spare part that retains all characteristics validated by the manufacturer:

Characteristic Value
Manufacturer HEINE Optotechnik (manufactured in Germany)
Technology Xenon halogen XHL (XHL Xenon)
Voltage 2.5 V
Amperage 0.3 A
Manufacturer reference X-001.88.056 (also X-01.88.056 and XHL 056)
Series XHL Xenon
Key compatibility Heine Mini 2000 and Minilux otoscopes
Application ENT and general diagnostic examinations
Installation Simple and safe in the instrument head, no tools required

Additional technical features:

  • Halogen technology: Bright and stable light for professional and constant illumination.
  • Voltage: 2.5 V, compatible with Heine XHL Xenon equipment.
  • Service life: Up to 50% longer than conventional bulbs.
  • Installation: Easy and safe on Heine devices, ensuring reliable performance.
  • Application: Ideal for diagnostic procedures requiring high precision.

Equivalences and cross-references

The Heine #056 lamp corresponds to the original reference X-001.88.056, also cited as X-01.88.056, XHL 056 and X0188056. It is designed exclusively for the Mini 2000 and Minilux otoscopes. There are equivalent compatible lamps on the market, such as the Specmedica 100104 X-001.88.056 equivalent lamp for the Minilux and Mini 2000 otoscope, and distribution alternatives for Heine within the 2.5 V XHL family. It shares a platform with other lamps from Heine’s 2.5 V XHL series (models #035, #037, #038, #041, #042, #105 and #110), so in some instruments it may be interchangeable depending on the specific head. It must not be confused with the 3.5 V lamps in the series (models #044, #049 and #051).

Selection tips and variants of interest

Before replacing the lamp, verify that your otoscope head operates at 2.5 V and check the number engraved on the base of the current bulb to confirm that it is model #056. The Heine series also offers 3.5 V lamps (models #044 and #049) for transilluminators, F.O. laryngoscope handles and speculum tips, which must not be confused with this variant. Also check the condition of the head housing and use gloves or a clean cloth when handling the bulb to avoid damaging the glass. For optimal performance and extended service life, it is recommended to always use original Heine spare parts: imitations alter the colour temperature and luminous intensity and compromise the instrument’s warranty. If your equipment supports the upgrade, consider Heine’s HQ LED modules as a long-lasting alternative.

Additional information

Manufacturer

HEINE Optotechnik (Germany)

Technology

Xenon halogen XHL

Voltage

2.5 V

Amperage

0.3 A

Manufacturer reference

X-001.88.056

Product line

XHL Xenon

Compatibility

Heine Mini 2000 and Minilux Otoscope

Application

ENT and general diagnostic examinations

Installation

Simple and safe, no tools required

Product type

Original spare part

Reviews

There are no reviews yet.

Be the first to review “Heine XHL Xenon Halogen 2.5 V #056 Replacement Lamp for Mini 2000 and Minilux Otoscope | Ref. X-001.88.056”

Your email address will not be published. Required fields are marked *