Description
1. Introduction
The replacement terminals for endoscopy cable CUDA Surgical are the recommended replacement to restore the connector end of the fibre optic cables used in endoscopy, rigid endoscopes, surgical headlights and light sources. As the component that withstands the greatest mechanical and thermal wear, its periodic replacement maintains the original light transmission of the assembly without the need to purchase a complete new cable, resulting in savings in the maintenance programmes of the operating theatre, sterilisation centre and medical electronics. Distributed in Spain by Cahnos, this product is supplied on quotation: request your personalised quote from our technical-commercial team.
2. Technical explanation
The fibre optic cable carries the light generated by the headlight or light source to the endoscopic instruments or optics with minimal losses. The ends of the cable are the critical points of the system: the proximal terminal connects to the light source and the distal one to the instrument, and both concentrate the light into the fibre bundle. When these connectors deteriorate through continuous use, impacts, repeated sterilisation cycles or twisting, the quality of illumination is reduced and the fibre can be damaged.
These CUDA Surgical replacement terminals are designed to replace the deteriorated connector of the cable, manufactured from medical-grade materials in their own facilities and under the quality standards of the equipment manufacturer (ISO 13485 and compliance with US FDA regulations). Correct fitting of the terminal restores the alignment of the fibre bundle and the secure connection with the source and the instrument, preserving the luminous performance of the assembly.
3. Technical Specifications
| Characteristic | Specification |
| Brand | CUDA Surgical (USA) |
| Product type | Replacement terminals for endoscopy fibre optic cable |
| Application | Replacement of connectors on endoscopy cables, headlights and light sources |
| Materials | Medical-grade materials |
| Regulatory standard | Manufactured in accordance with ISO 13485 and FDA (US) regulations |
| Commercialisation | On quotation (consult rate with Cahnos) |
Available references
| Reference | Description |
| ABM-TERMINALES-DE-REEMPLAZO-PARA-CABL-6E3060 | Replacement terminals for endoscopy cable CUDA Surgical |
4. Equivalences and Cross-References
CUDA Surgical manufactures high-quality spare parts compatible with the lighting systems of other leading market manufacturers, including Luxtec, Welch-Allyn (Welch Allyn), BFW, Aculux, Applied Fiberoptics and Isolux. There is no official equivalence table validated by the manufacturer that cross-references this specific part with codes from other brands; before replacing a terminal from another supplier, confirm with the Cahnos technical department the connector type (source end and instrument end), the fibre bundle diameter and the length of your cable.
Within the CUDA Surgical family itself distributed by Cahnos, this product is complemented by the following items:
| Related product | SKU / Reference |
| CUDA replacement optical fibre cables for headlights and light sources | ABM-CABLES-CUDA-DE-REEMPLAZO |
| CUDA DRH-100B surgical headlight with RCS system | ABM-FOTOFORO-CUDA-DRH-100B-CON-SISTEMA-RCS |
| CUDA DRH-80B surgical headlight with RCS system | ABM-FOTOFORO-CUDA-DRH-80B |
| CUDA Neuro CNH-80B Surgical Light | ABM-FOTOFORO-CUDA-NEURO-CNH-80B |
5. Selection tips and variants of interest
When requesting a quote, indicate the cable model, the headlight or light source you work with and the end you wish to replace (proximal towards the source or distal towards the instrument). The CUDA cable range is distinguished by its configuration (bifurcated BIF for two-branch systems or straight STR) and by the fibre bundle diameter (e.g., 3.5 mm and 5.0 mm), essential data to ensure terminal compatibility.
Periodically inspect the connectors of your cables: if you notice loss of brightness, looseness in the coupling or visible damage to the terminal, consider replacing the connector using these terminals before the fibre suffers irreversible damage. Preventive maintenance of the cable-terminal assembly extends the service life of the lighting system and ensures a correctly illuminated surgical field. For mixed equipment fleets or institutional purchases, contact the technical-commercial team at Cahnos: we will locate the appropriate variant within the CUDA Surgical catalogue. This product is supplied on quotation.