Description
1. Introduction
Medline’s polyisoprene ultrasound probe covers are the ideal solution for protecting the ultrasound transducer during examination, while also ensuring hygiene between patients. This non-sterile (latex-free) presentation is part of Medline’s sterile equipment covers range (Probe Covers) and the Microtek equipment covers portfolio, designed to reinforce equipment protection and efficiency in the operating theatre, examination rooms and diagnostic imaging consultations.
2. Technical Explanation
The cover is manufactured in soft-touch polyisoprene, a latex-free synthetic material that provides great flexibility and mechanical strength without interfering with the quality of the ultrasound image. Its main function is to create a barrier between the probe and the patient’s skin, reducing the risk of cross-contamination between patients and equipment during ultrasound procedures. As a single-use product, it limits the need for repeated disinfection of the transducer between patients, streamlines workflow in the examination room and helps preserve the condition of the equipment head. It is available in multiple sizes to fit different types of probes (linear, convex, endocavitary and compact geometry).
3. Technical Specifications
| Characteristic | Detail |
| Brand | Medline |
| Medline family | P-UD89B |
| Main reference | MDLP-UD89B |
| Material | Soft and flexible polyisoprene, latex-free |
| Sterility | Non-sterile (NS) |
| Use | Ultrasound probe / ultrasound transducer protection |
| Range | Sterile equipment covers (Probe Covers) · Microtek portfolio |
| Presentation | 100 units per pack · 1,000 units per case (exception ref. 88654: 800 units/case) |
The range is available in multiple sizes to fit different types of probe:
Available references
| Reference | Dimensions | Units per box | Units per pack |
|---|---|---|---|
| 88612 | 50 x 300 mm | 1000 | 100 |
| 88613 | 22 x 36 x 350 mm | 1000 | 100 |
| 88653 | 60 x 300 mm | 1000 | 100 |
| 88654 | 40 x 32 x 400 mm | 800 | 100 |
| 88662 | 20 x 300 mm | 1000 | 100 |
| 88663 | 26 x 300 mm | 1000 | 100 |
| 88676 | 30 x 300 mm | 1000 | 100 |
| 88684 | 40 x 300 mm | 1000 | 100 |
| 88704 | 36 x 300 mm | 1000 | 100 |
| 88607 | 44 x 18 x 310 mm | 1000 | 100 |
4. Equivalences and Cross-References
The main reference MDLP-UD89B corresponds to the Medline P-UD89B family. Each numerical variant (88612, 88613, 88653, 88654, 88662, 88663, 88676, 88684, 88704 and 88607) also has its equivalent with the MDL prefix (MDL88612, MDL88613, MDL88653, MDL88654, MDL88662, MDL88663, MDL88676, MDL88684, MDL88704 and MDL88607). All are part of the same range of Medline polyisoprene probe covers; the choice between one reference or another depends on the width, length and type of probe to be protected. As a comparable variant within the same manufacturer family, Medline offers the sterile polyisoprene series (family P-SZ11Q / ref. MDLP-SZ11Q), also available at Cahnos for procedures requiring sterility. No 1:1 equivalence with covers from other manufacturers has been verified; it is recommended to validate compatibility with the transducer and cross-references before tendering.
5. Selection tips and variants of interest
To select the appropriate reference, measure the base and useful length of the ultrasound probe and choose the series width (X) that fits snugly without tension. As a guide, the 20–36 mm models (88662, 88663, 88676, 88704) fit linear and small-diameter probes; the 40–60 mm ones (88684, 88612, 88653) are suitable for convex and medium-sized probes; the compact-geometry variants 88613 (22 x 36 x 350 mm), 88654 (40 x 32 x 400 mm) and 88607 (44 x 18 x 310 mm) are recommended for rectangular-section transmitters or longer formats, such as endocavitary probes. As this is a non-sterile presentation, confirm the requirements of your centre’s protocol: if a sterile barrier is required during examination, consider the sterile range of the same family. Always request a quote at Cahnos for institutional quantities, especially in full-case formats intended for stock replenishment.












Reviews
There are no reviews yet.