Description
1. Sterile protection for your Siemens C-arm
The C-arm set SIREMOBIL N4 (Ref. DYNJE4532) is the ideal hygienic solution for protecting Siemens mobile radiology equipment during interventional, traumatology and diagnostic imaging procedures. Made from high-quality transparent polyethylene drape, these sterile covers create a disposable barrier between the equipment and the surgical field without compromising perfect visibility of the monitor, controls and work area. A practical, economical and single-use response for the most demanding infection control protocols in operating theatres, radiology rooms and traumatology centres.
2. Technical explanation of the equipment and procedure
The C-arm is a mobile X-ray unit that moves and rotates over the patient during surgery and diagnosis, so any contact with the sterile field must be protected. This set acts as a disposable physical barrier covering the X-ray tube, image intensifier and the arm itself, preventing cross-contamination between patient and equipment. Its design with securing clips (compatible with the basic set SPTE-SS628) and elastic system allows a firm, ergonomic fit, with placement and removal in seconds without compromising the integrity of the sterile barrier. The transparent polyethylene preserves visual reading of the equipment and controls, facilitating handling of the intensifier and connections throughout the procedure.
3. Technical Specifications
Main features of the DYNJE4532 cover set:
| Characteristic | Specification |
| Reference / SKU | DYNJE4532 |
| Material | High-quality transparent polyethylene (PE) drape |
| Holding system | Securing clips (basic set SPTE-SS628) and elastic for a firm fit |
| Compatibility | Siemens SIREMOBIL N4 C-arm and basic set SPTE-SS628 |
| Coverage | C-arm, X-ray tube and image intensifier |
| Sterility | Sterile, single-use |
| Visibility | Total transparency of the equipment during the procedure |
| Presentation | 10 units per pack; 20 packs per box (200 covers) |
| Application | Operating theatres, radiology rooms, traumatology and interventional procedures |
Range of sets and drapes for Siemens C-arms from Cahnos:
| Reference | Compatible equipment | Format |
| DYNJE4532 | SIREMOBIL N4 | Set of covers with clips and elastic |
| DYNJE4547 | SPTE-SS628 set (Siemens) | Sterile cover set with clips and elastic |
| DYNJE4556 | ISO-C, Arcadis and Orbic | 2-part set with clips and elastic |
| ICE1012 | Fluoroscope / C-arm | Drape 91 x 113 cm with adhesive strips and tabs |
4. Equivalences and Cross-References
This set belongs to the range of sterile C-arm covers from Cahnos, conceived under the same philosophy as the InvisiShield family from Medline: transparent polyethylene film and secure fixation using clips. In the reference catalogue of the EDM/InvisiShield family, the specific cover for SIREMOBIL N4 corresponds to reference 17632, while the universal cover with clips from the same range is 17687 and the cover for image intensifier/X-ray tube is 17587; all of them are used mandatorily with the Siemens basic kit 17628, equivalent to our basic set SPTE-SS628. For other Siemens equipment, Cahnos offers DYNJE4547 (set SPTE-SS628) and DYNJE4556 (ISO-C / Arcadis / Orbic in 2 parts), as well as the drape for fluoroscope ICE1012. For Ziehm equipment, reference DYNJE4531, and for Philips, the series DYNJE4526 to DYNJE4569. If you regularly use a reference from another manufacturer, consult our technical-commercial team to validate the exact equivalence before placing the order.
5. Selection tips and variants of interest
Verify the exact model of your C-arm and the image intensifier configuration before selecting the reference. This data sheet DYNJE4532 is specifically indicated for Siemens SIREMOBIL N4 equipment with basic set SPTE-SS628; if your fleet is of the standard SPTE-SS628 series, select DYNJE4547, and for ISO-C, Arcadis or Orbic equipment, DYNJE4556. For C-arms from other manufacturers, the range is extended with the series DYNJE4526-DYNJE4531 (Philips BV and Ziehm) and with the drapes ICE4400/ICE4400R, ICE4405, ICE4410, ICE4420 and ICE4430 for full-size C-arms and mini C-arms. It is recommended to replace the cover after each patient or procedure to ensure maximum sterility and to store the boxes in a dry, cool place to preserve the integrity of the polyethylene. For complete fittings of operating theatres, radiology rooms or public tenders, contact our commercial team for special supply conditions.












Reviews
There are no reviews yet.