Description
The PBS line containers are the reference solution for the collection, storage and transport of sharps in the healthcare environment: needles, syringes, scalpel blades, lancets and any element that could cause cuts or puncture injuries. A complete range covering from the consultation blood collection point to high-turnover hospital areas, with a design focused on professional safety and regulatory compliance in the management of clinical waste.
Technical explanation
These containers are manufactured to withstand daily use by healthcare personnel with proven safety levels. They feature a practical opening system, temporary closure for continued use and permanent closure for sealing the container when it reaches its maximum fill level, with a certified hermetic seal that prevents spillage of its contents. They incorporate a needle extraction device and insulin pen needle removal device, allowing the sharp element to be discarded without manual handling. The body is resistant to impacts and punctures, offers excellent stability and has a robust handle that facilitates transport. All models carry the UN mark that qualifies them for the transport of dangerous goods, are autoclavable at 134 °C for 18 minutes and do not emit harmful gases during the incineration process. Their label is customisable to record quantities and traceability. Square or round shape depending on capacity.
Technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Product | Container for sharps and cutting waste (Sharps container) |
| Available capacities | 0.6 l | 1.5 l | 2 l | 5 l | 6 l | 7 l | 12 l |
| Closure | Temporary and permanent, with certified hermetic seal |
| Integrated devices | Needle extraction and insulin pen needle removal |
| Safety | Resistant to impacts and punctures |
| Shape | Square or round depending on capacity |
| Sterilisation / Treatment | Autoclavable at 134 °C for 18 minutes |
| Incineration | No emission of harmful gases during the process |
| Transport | UN mark for transport of dangerous goods |
| Origin | Made in Italy |
| Device type | Not a medical device (No medical device) |
Available references
| Reference | Capacity | Sales unit | Details |
|---|---|---|---|
| GM25790 | 0.6 l | Box of 100 units | PBS 0.6 l – Ø 10 x h 14.5 cm |
| GM25791 | 1.5 l | Box of 100 units | PBS 1.5 l – Ø 14 x h 16.5 cm |
| GM25792 | 2 l | Box of 75 units | PBS 2 l – Ø 14 x h 21 cm |
| GM25793 | 5 l | Box of 55 units | PBS 5 l – Ø 21.4 x h 19.5 cm |
| GM25794 | 7 l | Box of 40 units | PBS 7 l – Ø 25 x h 19.5 cm |
| GM25795 | 12 l | Box of 25 units | PBS 12 l – Ø 25 x h 31.3 cm |
| GM25796 | 6 l | Box of 55 units | PBS 6 l – Ø 21.4 x h 24 cm |
Equivalences and cross-references
No validated equivalence table has been found in reliable sources that cross-references the PBS line references (25790-25796) with exact codes from other manufacturers, so it is not recommended to substitute these references without prior verification. Within the catalogue distributed by Cahnos, this range is complemented by other waste management products: the tray with compartments ref. GM37725 is designed by the manufacturer to fit with the PBS 25790, 25791 and 25792 containers and with the CS 25782 container, facilitating the orderly transport of small containers in consulting rooms and wound dressing rooms. For the collection of general waste in a clinical environment, the stainless steel pedal bin ref. GM44902 (20 l) completes the equipment of the wound dressing area. Consult our technical-commercial team to validate the compatibility of any reference in specifications or tenders.
Selection tips and variants of interest
Choose the capacity according to the waste generation point: the 0.6 l and 1.5 l references (GM25790 and GM25791) are ideal for wound dressing trolleys, extraction booths and nursing stations with medium rotation; the 2 l and 5 l (GM25792 and GM25793) cover wound dressing rooms and high-activity consulting rooms; and the 6 l, 7 l and 12 l (GM25796, GM25794 and GM25795) are recommended for operating theatres, emergency departments, laboratories and centralised waste areas. The permanent closure must be activated when the maximum fill level line is reached, before removing the container for treatment or incineration. As it is a product autoclavable at 134 °C for 18 minutes, it can undergo prior decontamination according to the centre’s protocols. To complete the transport solution for small models, consider the tray with compartments GM37725. For large orders you can request a quote: contact the technical-commercial department of Cahnos for B2B volume conditions.














Reviews
There are no reviews yet.