The transport stretcher manufacturer ref. 44792 is the professional solution for the safe and comfortable transfer of patients in hospitals, clinics and social health centres. Designed on columns and with a 3-section radiolucent HPL surface, it allows transport and radiological examinations to be carried out without unnecessary patient transfers. Its hydraulic lifting system with pedal on both sides, its Trendelenburg and reverse Trendelenburg positions and its high load capacity of 260 kg make it a versatile, robust piece of equipment suitable for intensive use, even on long-distance transfers. It comes as standard with a pair of folding safety side rails.
2. Technical explanation of the equipment
This stretcher is designed with a epoxy powder-coated steel chassis and a horizontal radiolucent HPL surface with 1 articulation and 3 sections. The head section is continuously adjustable by gas springs up to 80°, the backrest is operated with gas assistance and the foot section is adjusted by means of a rastomat system, facilitating ergonomic positioning of the patient and healthcare staff. The working height is hydraulically adjustable from 550 to 850 mm with a wide pedal on both sides of the stretcher, and additional side pedals allow the Trendelenburg and reverse Trendelenburg positions (−18°/+18°) to be reached.
The base incorporates a protective cover and compartment for oxygen cylinders and objects. Mobility is guaranteed by four swivel castors of Ø 200 mm, one of them with directional lock, and a centralised simultaneous braking system via a pedal located on the foot section. The three-position control pedal (1 free, 1 directional and 1 total lock) always ensures correct braking. The folding side rails with scissor action, made of extruded aluminium alloy, have automatic locking and dual lowering position, while the folding handles on the foot section facilitate pushing. As an option, a height-adjustable IV pole with 4 hooks can be incorporated.
3. Technical Specifications
| Overall external dimension | 2060 x 820 x h 550-850 mm |
|---|---|
| Surface / Weight | 1950 x 650 mm / 105 kg |
| Maximum head section inclination | 80° |
| Trendelenburg / RTR | − 18° / + 18° |
| Maximum patient load | 260 kg |
| Regulatory standard | MDR 2017/745; Medical device Class I |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 44792 |
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | I |
| CND | V0899 |
| EAN | 8023279447927 |
Main characteristics
| Flat | Radiolucent HPL, 1 articulation and 3 sections |
|---|---|
| Height adjustment | Hydraulic via pedal on both sides, 550-850 mm |
| Positioning | Trendelenburg and reverse Trendelenburg (−18°/+18°) via side pedals |
| Headrest | Continuously adjustable with gas springs up to 80° |
| Structure | Epoxy powder-coated steel, with multifunctional corner supports (up to 2 accessories per corner) |
| Side | Pair of folding side rails with scissor action, extruded aluminium, automatic locking and dual lowering position |
| Wheels | 4 swivel castors of Ø 200 mm, one with directional lock |
| Braking system | Centralised simultaneous braking via pedal on the foot section; 3-position control pedal (free, directional, total lock) |
| Base | With protective cover and compartment for oxygen cylinders and objects |
| Accessories | Height-adjustable IV pole with 4 hooks (optional) |
| Manufacture | Made in Italy |
4. Equivalences and Cross-References
This product corresponds to reference 44792. (commercial SKU GM44792, EAN 8023279447927). No official equivalence table published by the manufacturer has been found that cross-references this code with third-party codes, so no verifiable direct equivalents are indicated. Functionally, within the Cahnos catalogue it is comparable to other transport stretchers with hydraulic lifting and Trendelenburg positioning, such as the UDW 2500 from RCN (shower and transport stretcher with hydraulic height from 49 to 89 cm) or the A-magnetic adjustable-height stretcher CAHNOS-5501, although these are comparisons by features and not 1:1 interchangeable. To validate exact equivalents in technical specifications or supply tenders, please consult our technical-commercial department.
5. Selection tips and variants of interest
Check the maximum load required: this stretcher supports up to 260 kg of patient, so it is suitable for most profiles, including long-distance transport. Verify the clearance through doors and lifts with the external dimension of 2060 x 820 mm and the width of the surface of 650 mm. If your service performs radiological examinations, the radiolucent HPL surface avoids patient transfers between the stretcher and the examination table. For administration of sera or infusion, incorporate the adjustable drip stand with 4 hooks (optional) in the multifunctional corner supports. Carry out periodic maintenance of the hydraulic system, wheels and brakes following the manufacturer’s instructions to ensure the safety and durability of the equipment.