Description
1. Commercial Introduction
The replacement cell Ref. 28581 is the manufacturer’s original spare part designed specifically for the pressure-relieving water mattress Ref. 28580. Its function is to maintain the pressure redistribution capacity of the whole unit: a damaged cell compromises hydrostatic discharge and patient comfort, so having original spare parts is essential to extend the mattress’s service life and ensure continuity of care in hospitals, nursing homes, clinics and social healthcare centres.
As a factory spare part, this cell retains exactly the same construction, materials and behaviour as the original element, ensuring a perfect fit and performance equivalent to the standard unit. Distributed by Cahnos. For large orders you can request a quote.
2. Technical explanation of the spare part
Pressure-relieving water mattresses work by hydrostatic discharge: the liquid contained in each element moves with the patient’s movement, adapting to the body contour and distributing pressure evenly over the support surface. This reduces load peaks on bony prominences such as the sacrum, heels, shoulder blades and elbows, the main risk areas for pressure ulcers in bedridden patients.
Each water cell is an independent element of the system: if one of them leaks, loses its seal or becomes deformed through intensive use, the pressure is redistributed irregularly across the entire surface. Replacing it with this original spare cell restores uniform load distribution, maintains the stability of the containment frame and returns the mattress to its comfort and prevention performance. Before replacement, verify compatibility with the mattress model Ref. 28580 and follow the manufacturer’s filling instructions.
3. Technical specifications and product data
Original water cell spare part for the pressure-relieving water mattress Ref. 28580. Manufacturer’s spare part, with no reference transcriptions or modifications.
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 28581 |
| Reference Cahnos (SKU) | GM28581 |
| Compatibility | Pressure-relieving water mattress Ref. 28580 |
| Part type | Replacement cell (water element) |
| Sales unit | 1 pc |
| Device type | Spare part |
| EAN | 8023279285819 |
4. Equivalences and Cross-References
Reference 28581 corresponds to the manufacturer’s official code for the replacement cell of the pressure-relieving water mattress Ref. 28580 (EAN 8023279285819), with no transcriptions or normalisations. No validated 1:1 equivalence table has been found in reliable sources cross-referencing this code with specific codes from other manufacturers of water or air pressure-relieving systems; any substitution in tenders or protocols must be validated field by field with the technical-commercial department of Cahnos.
Within Cahnos’s own catalogue of pressure-relieving surfaces there are products from the same family, comparable in terms of clinical indication although not interchangeable 1:1, such as the pressure-relieving water mattress with air frame (Ref. 28502) or the alternating pressure-relieving mattress kit with pump (Ref. 28582).
5. Selection tips and variants of interest
Always confirm that your mattress corresponds to model Ref. 28580 before requesting this spare part; water cells from other references may differ in dimensions, volume or connection system. Periodically inspect the condition of the cells, seams and valves to detect leaks or loss of seal, and replace only with original manufacturer spare parts.
For filling, follow the instructions and do not overfill the cell: correct filling is crucial for balanced pressure distribution and seam durability. Clean the surface with a mild detergent and dry the whole unit completely before each use, avoiding sharp objects that could damage the material. For complete fittings, supply contracts or orders of several spare parts, contact Cahnos’s technical-commercial team for special conditions and a formalised quote.