We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Low electric articulated hospital bed with Trendelenburg – 3 articulations, 4 sections, adjustable height 23-63 cm | Ref. 27672 (SKU GM27672)

2.232,50 €

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

Low electric hospital bed with 3 articulations and 4 sections with Trendelenburg position (ref. 27672). Electrically adjustable platform height from 23 to 63 cm to reduce the risk of falls and facilitate transfers in hospitalisation, geriatrics and care homes. Backrest and legs operated by two independent 24 V DC electric motors with push-button, foot section adjustable by rack-and-pinion and fixed pelvic section. Fully welded structure in rectangular steel tube 50x25x2 mm, mattress platform 900×2,000 mm with flexible wooden slats and retaining guides, removable headboard and footboard in natural beech wood. Includes 2 sliding vertical bars with keys, lifting bar and 4 Ø 100 mm swivel castors with independent brake. Maximum load 135 kg, power supply 230 V – 50 Hz. Class I medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM27672

Description

1. Commercial Introduction

The low electric hospital bed (ref. 27672) is the robust technical solution for hospitalising adult patients in hospitals, clinics, care homes and social-health centres seeking to minimise the risk of falls. Its fully electric operation, Trendelenburg position and low working height (23 to 63 cm) allow healthcare staff to adapt the bed surface to each care procedure, improve ergonomics and offer the patient comfortable, easily accessible rest.

Its welded steel construction with natural beech wood finishes makes it a highly robust piece of equipment, perfectly integrable into any clinical or residential room.

2. Technical explanation of the equipment

This bed features a 3-articulation frame with 4 sections (backrest, fixed pelvic section, legs and feet) with an electrically adjustable platform height from 23 to 63 cm and Trendelenburg position. The backrest and leg sections are adjusted independently by two 24 V DC electric motors with push-button, allowing precise and smooth positioning of the patient; the foot section is adjusted by a rack-and-pinion device and the pelvic section remains fixed to provide stability and support.

The main frame, fully welded, is made of rectangular steel tube 50x25x2 mm, and the mattress platform incorporates flexible wooden slats with retaining guides that prevent the mattress from shifting during movement. The set is completed with removable headboard and footboard in natural beech wood with solid corners and edges, 2 sliding vertical bars with upper and lower locking/unlocking keys, a lifting bar and 4 swivel castors of Ø 100 mm with independent brake for safe mobilisation.

3. Technical Specifications

Characteristic Value
Platform size 900 x 2,000 mm
Platform height 230-630 mm (23-63 cm)
External dimensions 1,030 x 2,140 mm
Maximum load 135 kg
Weight 102 kg
Power supply 230 V – 50 Hz

Construction and equipment features

Item Description
Configuration 3 articulations, 4 sections
Height adjustment Electric, with Trendelenburg position
Adjustable sections Backrest and legs via 2 independent 24 V DC electric motors with push-button
Foot section Adjustable by rack-and-pinion device
Pelvic section Fixed
Main structure Rectangular steel tube 50x25x2 mm, fully welded
Mattress platform Flexible wooden slats with mattress retaining guides
Headboard and footboard Removable, natural beech wood with solid corners and edges
Wheels 4 swivel castors Ø 100 mm with independent brake
Included accessories 2 sliding vertical bars with upper and lower locking/unlocking keys and lifting pole

Product data

Field Value
Manufacturer GIMA
Manufacturer reference 27672
SKU Cahnos GM27672
Sales unit 1 unit
Device type Medical device (Medical device)
Device class I
CND Y181210
EAN 8023279276725

4. Equivalences and Cross-References

Reference 27672 (EAN 8023279276725, SKU Cahnos GM27672) is the manufacturer’s official code for this low electric hospital bed with 4 sections and Trendelenburg. There is no official equivalence table validated by the manufacturer that cross-references this code 1:1 with codes from other manufacturers; any substitution in a specification, tender or existing fleet must be validated field by field (platform dimensions, height range, drive system, maximum load and accessories) against each brand’s official technical data sheet.

Available references

Reference Description Sales unit
GM27672 Low electric bed, 3 articulations/4 sections with Trendelenburg, height 23-63 cm (Ref. 27672) 1 unit

Within the same range of hospital beds available at Cahnos, the following references stand out as of interest: GM27673 (articulated electric bed with Trendelenburg, height 40-80 cm), GM27684 (electric bed with 4 motors, adjustable height and solid beech headboard), GM44800 and GM44799 (electric beds with adjustable height, 3 articulations and 4 sections, with higher load capacity). As room complements, the wooden bedside tables GM27676 and GM27677 are specifically designed for beds Ref. 27672/27673.

5. Selection tips and variants of interest

For the equipping of hospitalisation wards, care homes or social-health centres, verify the compatibility of the 900 x 2,000 mm platform with the mattresses in your existing stock and the space available in the room, considering the external dimensions of 1,030 x 2,140 mm and the passage through doors and lifts. Confirm the mains voltage of the installation (230 V – 50 Hz) and remember that the 4 swivel castors have independent brakes to immobilise the bed during care.

This low bed is the recommended option when you need to reduce the patient’s fall distance, facilitate bed-to-chair transfers and achieve a natural beech wood aesthetic that integrates into centres and care homes. The maximum load of 135 kg makes it suitable for most adult patients; if you require a higher weight capacity, a greater height range (40-80 cm) or advanced functions, consider references GM27673, GM27684, GM44800 or GM44799 from the same range.

For large orders you can request a quote: request an offer from your technical-commercial advisor, indicating the number of units, destination and additional accessories.

Additional information

Manufacturer reference

27672

EAN

8023279276725

CND code

Y181210

Device type

Medical device (Medical device)

Configuration

3 articulations, 4 sections

Platform dimensions

900 x 2,000 mm

Platform height

230-630 mm (23-63 cm)

Dimensions

1,030 x 2,140 mm

Weight

102 kg

Main structure

Rectangular steel tube 50x25x2 mm, fully welded

Mattress platform

Flexible wooden slats with mattress retaining guides

Motors

2 independent 24 V DC electric motors with push-button

Foot section

Adjustable by rack-and-pinion device

Pelvic section

Fixed

Headboard and footboard

Removable, natural beech wood with solid corners and edges

Wheels

4 swivel castors Ø 100 mm with independent brake

Included accessories

2 sliding vertical bars with upper and lower locking/unlocking keys and lifting pole

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Capacidad peso

135 kg

Alimentacion

Mains power

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Low electric articulated hospital bed with Trendelenburg – 3 articulations, 4 sections, adjustable height 23-63 cm | Ref. 27672 (SKU GM27672)”

Your email address will not be published. Required fields are marked *