Description
1. Commercial Introduction
The 2B motor (Ref. 45164) is the reference replacement part for 2-motor examination chairs and clinical recliners. Designed to operate the backrest and footrest, this spare part restores all patient reclining and positioning functions to your medical chair, avoiding the need to replace the entire unit. It is the ideal solution for practices, clinics, physiotherapy suites and diagnostic centres that need to keep their clinical furniture operational with an original part.
2. Technical explanation of the spare part
This double linear electric motor (2B) is part of the electromechanical system of 2-motor examination chairs: the first actuator controls the elevation and angle of the backrest, while the second moves the footrest to adapt the patient’s position during examination or treatment. As a specific replacement part for this configuration, it replaces the original motor when it loses power, makes abnormal noises or stops working, restoring the reclining and extension movements with complete smoothness and safety. Installation must be carried out respecting the chair’s mounting and wiring; it is recommended to check the compatibility of the removed motor with this reference before replacement.
3. Technical Specifications
Product data verified in the manufacturer’s catalogue (Product_DB):
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 45164 |
| Motor model | 2B motor for 2-motor chairs |
| Function | Backrest and footrest |
| Chair configuration | 2 motors |
| Sales unit | 1 pc |
| Device type | Spare part (spare part) |
| EAN | 8023279451641 |
Note: as this is a spare part, always check the reference of the motor fitted in your chair and the mounting and connection characteristics before placing the order.
4. Equivalences and Cross-References
The reference 45164 is the manufacturer’s official code for this replacement part. No manufacturer-validated equivalence table has been found that cross-references this part with references from other manufacturers; examination chair motors are not interchangeable between brands as standard, so it is recommended to check the model of the removed motor and the chair mountings with the technical service before any replacement or use in tenders.
5. Selection tips and variants of interest
Confirm your chair’s configuration: this 2B motor is specific to 2-motor examination chairs with backrest and footrest functions. Check the original motor reference and the mounting dimensions before replacement. If the fault affects only one of the functions, also check the control system and wiring, as an electrical fault may originate in the control unit rather than the motor. For chair fleets, maintenance contracts or institutional orders, contact the technical-commercial department at Cahnos to confirm exact compatibility with your equipment and receive a formalised quote.





Reviews