Description
1. Commercial Introduction
The X-ray table AGA-AKKU-POWER-DUO-LIFT from AGA Sanitätsartikel GmbH (Löhne, Germany) is the reference solution for radiology, traumatology and diagnostic imaging departments that need a mobile, reliable and always ready to use system. Its battery-powered drive allows height and tilt adjustment without the need for a permanent mains connection, making it ideal for multi-purpose rooms, home care and mobile radiology units. Each configuration (frame, upholstery colour, height and accessories) is quoted on request: contact our technical-commercial team at Cahnos for the exact configuration for your facility.
2. Technical explanation of the equipment
The AGA-AKKU-POWER-DUO-LIFT series incorporates two telescopic lifting columns of anodised light metal, controlled by a battery unit and operated via a hand control with spiral cable and six buttons (up, down and tilt functions). The height is adjusted electrically via battery over an approximate range of 460 to 860 mm, and the tilt offers Trendelenburg and anti-Trendelenburg positions of 17° each. The connection values per battery unit are: 230 V, 50/60 Hz, 4.0 A, 160 W, IPX6 protection, lifting speed 16 mm/s and drive force of the columns of 2 x 2,000 N.
The tabletop is made up of radiolucent support plates of black recycled PE-1000, so there are no metal parts in the area between the columns, avoiding artefacts during examination. In the two-section tabletop versions, the head section is adjusted via a grid with 13 locking steps up to +30° and can be mounted on the left or right (by default it is supplied on the right). Please note that on two-piece tabletops, the head section and the transition to the main surface are only partially radiolucent due to the hinges and the grid. The standard configuration includes a hand control with spiral cable and six buttons, battery holder and hand control holder on the right side, external battery charger and base frame with levelling feet.
3. Technical Specifications
Manufacturer’s specifications (source: official catalogue AGA Sanitätsartikel GmbH):
| Characteristic | Value |
|---|---|
| Brand | AGA (AGA Sanitätsartikel GmbH) |
| Series | AGA-AKKU-POWER-DUO-LIFT |
| Frame | Lacquered |
| Length | 1900 mm |
| Height adjustment | 460 – 860 mm (battery-powered) |
| 1-section tabletop | Yes |
| Tilt | 17° (battery-powered) |
| Maximum load | 150 kg |
System data per battery unit:
| Parameter | Value |
|---|---|
| Lifting columns | 2 anodised light metal telescopic columns |
| Connection values | 230 V, 50/60 Hz, 4.0 A, 160 W |
| Protection rating | IPX6 |
| Lifting speed | 16 mm/s |
| Drive force | 2 x 2,000 N |
| Headrest (2-section tabletop) | 13 locking positions, up to +30°, on the left or right |
| Control | Hand control with spiral cable, 6 buttons (key lock and emergency stop) |
Available references
| Reference AGA | Width | Support plate thickness | Radiolucent area | 2-section tabletop (500 / 1400 mm) |
|---|---|---|---|---|
| RGL-1065/NAC | 650 mm | 15 mm | 1200 x 600 mm | RGL-1065/NKAC |
| RGL-1080/NAC | 800 mm | 25 mm | 1200 x 750 mm | RGL-1080/NKAC |
The series is completed with the two-section tabletop versions with grid-adjustable head section: RGL-1065/NKAC (650 mm) and RGL-1080/NKAC (800 mm). The tabletop / support plates are made of recycled PE-1000, radiolucent and black in colour.
Accessories and available options
| Reference | Item | Detail | Type |
|---|---|---|---|
| LR-75 | Wheel set | Ø 75 mm. Four swivel castors, two of which are fully lockable; for table heights with castors of 560 – 960 mm. Please specify the desired total height with castors when ordering. | Accessory |
| LR-125 | Wheel set | Ø 125 mm. Four swivel castors, two fully lockable; for table heights with castors of 620 – 1,020 mm. Specify the desired total height when ordering. | Accessory |
| LR/Z-125 | Central locking castor system | Double swivel castors Ø 125 mm with excellent rolling properties, connected to each other by rods; pedals arranged diagonally at the head and foot ends, with colour markings (green = table ready to move, red = table locked). For heights with castors approx. 620 – 1,020 mm. Specify the desired total height when ordering. No possibility of subsequent installation. | Factory option |
| OPS-40/A · OPS-60/A · OPS-100/A · OPS-140/A · OPS-170/A | Standard rails (pair) | Lengths approx. 600, 1,000, 1,400 and 1,700 mm. CrNi steel, approx. 25 x 10 mm, mounted on the upholstery frame approx. 13.5 mm from the top frame with 2 (or 3) spacers. For holding accessories and radiation protection curtains for the lower body. No possibility of subsequent installation. | Factory option |
| PAL-190-65 | Upholstered mattress | For 650 mm tables. Thickness 40 mm, fixed under the tabletop frame with straps and Velcro. Available in 21 upholstery colours. | Accessory |
| PAL-190-80 | Upholstered mattress | For 800 mm tables. Thickness 40 mm, fixed under the tabletop frame with straps and Velcro. Available in 21 upholstery colours. | Accessory |
The original AGA battery module (ref. BMEAC) is the compatible power supply spare part for these tables to maintain their constant operational availability.
4. Equivalences and Cross-References
The references RGL-1065/NAC and RGL-1080/NAC are the official manufacturer nomenclature of AGA Sanitätsartikel GmbH for the battery-powered X-ray table with height and tilt of a one-piece tabletop; RGL-1065/NKAC and RGL-1080/NKAC correspond to the two-section tabletop versions with adjustable head section. In the Cahnos catalogue, the product is identified with the SKU AGA-AKKU-POWER-DUO-LIFT and the references may also appear as AGA-RGL-1065-NAC and AGA-RGL-1080-NAC.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| AGA Sanitätsartikel (same manufacturer) | AGA-AKKU-POWER-DUO-LIFT, width 650 mm, one-piece tabletop | RGL-1065/NAC | Series reference (standard configuration) | Width 650 mm, support plate 15 mm, radiotransparent area 1,200 x 600 mm |
| AGA Sanitätsartikel (same manufacturer) | AGA-AKKU-POWER-DUO-LIFT, width 800 mm, one-piece tabletop | RGL-1080/NAC | Series reference (standard configuration) | Width 800 mm, support plate 25 mm, radiotransparent area 1,200 x 750 mm |
| AGA Sanitätsartikel (same manufacturer) | AGA-AKKU-POWER-DUO-LIFT, two-section tabletop with adjustable head section | RGL-1065/NKAC · RGL-1080/NKAC | Variant of the same family (not 1:1 interchangeable without specification) | Head section with 13 steps up to +30°; the head and transition areas are only partially radiolucent |
| AGA Sanitätsartikel (same manufacturer) | AGA-AKKU-POWER-LIFT (battery-powered electric height only) | RGL-1065/AC · RGL-1080/AC | Comparable by category (not interchangeable 1:1) | Same mobile platform with 2-button control, without electric Trendelenburg/anti-Trendelenburg tilt |
| AGA Sanitätsartikel (same manufacturer) | AGA-POWER-DUO-LIFT (electric height and tilt with mains connection) | RGL-1065/NEE · RGL-1080/NEE | Comparable by category (not interchangeable 1:1) | Version with permanent mains connection, height 550 – 800 mm and 11° tilt |
No reliable source has been found for a 1:1 equivalence table validated by the manufacturer cross-referencing this table with specific codes from other brands; any comparison with X-ray tables from other manufacturers (e.g. MAQUET, TRUMPF or STERIS) should be treated as comparable by category (not interchangeable 1:1), always verifying the tabletop dimensions, maximum load and radiolucent area. Consult our technical department before using in a tender.
5. Selection tips and variants of interest
Choose the reference according to tabletop width and the needs of your room: RGL-1065/NAC (650 mm, 15 mm plate, radiolucent area of 1,200 x 600 mm) is the most compact option, while RGL-1080/NAC (800 mm, 25 mm plate, radiolucent area of 1,200 x 750 mm) offers a larger working surface and a wider examination area. If your practice needs an adjustable headrest to comfortably position the patient’s head, consider the two-section tabletop versions RGL-1065/NKAC or RGL-1080/NKAC, with 13 locking steps up to +30°; remember that the headrest position can be requested on the left or right (by default it is supplied on the right).
To complete the equipment, consider the upholstered mattress (PAL-190-65 or PAL-190-80, 40 mm, in 21 colours), the wheel sets (LR-75, LR-125) or the wheel system with centralised brake (LR/Z-125, factory option only and no subsequent mounting), as well as the standardised OPS rails for accessories and radiological protection curtains, which must also be ordered at source. If you only need battery-powered elevation without tilt, the AGA-AKKU-POWER-LIFT series (ref. RGL-1065/AC and RGL-1080/AC) offers the same platform with 2-button control; if you have a fixed mains socket, the POWER-LIFT and POWER-DUO-LIFT series cover the version with transformer. Each configuration is quoted on request; contact our technical-commercial team at Cahnos for quotes and delivery times.


















Reviews
There are no reviews yet.