Description
1. Equipment presentation
The examination couch AGA-DUO-LIFT is the professional solution from AGA Sanitätsartikel (Löhne, Germany) for medical practices, examination units, diagnostic centres and consulting rooms that need to position the patient precisely and effortlessly. It combines two motorised movements as standard —height adjustment and surface tilt— to adapt the table to the ergonomic height of the professional and to the clinical requirements of each examination.
We supply this equipment on request with a formal quotation: each couch is configured according to frame finish, width and accessories. Our technical-commercial department will advise you on selecting the most suitable reference for your centre.
2. Technical explanation of the equipment
The AGA-DUO-LIFT is an examination table with 2 sections (head section and main body) operated by two low-voltage electric lifting columns made of anodised aluminium and characterised by smooth and quiet operation. The columns are controlled by a transformer and a 6-button hand control with multifunction capability, which allows simultaneous operation of the height and tilt of the surface.
The independent movement of both columns allows the surface to be tilted to adopt the Trendelenburg and anti-Trendelenburg positions of 11°, facilitating certain procedures and improving the clinician’s access. The head section has continuous adjustment up to +40° with locking via a rod handle; the upholstery, 64 mm thick, ensures patient comfort during prolonged examinations. The structure combines reinforcement plates at the corners of the frame and a large-surface base with levelling feet, providing excellent stability in daily use.
The finish of the upholstery frame can be lacquered, chrome-plated or stainless steel (the lower frame is always supplied lacquered). The motors offer a speed of 16 mm/s with a force of 2 x 1,000 N and IPX6 protection.
3. Technical specifications and references
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Length | 1900 mm |
| Head section / main board | 500 / 1400 mm |
| Height adjustment | 600 – 850 mm (electric motor) |
| Trendelenburg / anti-Trendelenburg | 11° each (electric motor) |
| Upholstery sections | 2 sections |
| Upholstery thickness | 64 mm |
| Headrest adjustment | +40° (locking rods) |
| Maximum load | 150 kg |
Electrical system data
| Parameter | Value |
|---|---|
| Actuation | 2 low-voltage electric columns (anodised aluminium) |
| Motor connection values | 230 V · 50/60 Hz · 6.0 A · 240 W |
| Protection rating | IPX6 |
| Speed / Force | 16 mm/s · 2 x 1,000 N |
| Control | 6-button hand control (multifunction) |
| Available widths | 650 mm and 800 mm |
| Upholstery frame finishes | Lacquered, chrome-plated and stainless steel (lower: lacquered only) |
Available references
| Reference AGA | Frame | Width |
|---|---|---|
| H-U 1065/EE 850 | Lacquered | 650 mm |
| H-U 2065/EE 850 | Chrome-plated | 650 mm |
| H-U 3065/EE 850 | Stainless steel | 650 mm |
| H-EKG 1080/EE 850 | Lacquered | 800 mm |
| H-EKG 2080/EE 850 | Chrome-plated | 800 mm |
| H-EKG 3080/EE 850 | Stainless steel | 800 mm |
Accessories and available options
| Reference | Item | Detail | Type |
|---|---|---|---|
| GS-1710 | Facial opening in the head section | In the head section upholstery, oval shape, dimensions approx. 205 x 105 mm (L x W). Retrofit not possible. | Factory option |
| EfGS | Upholstery insert | For closing the facial opening, oval shape, dimensions approx. 200 x 100 mm (L x W). See upholstery colours. | Factory option |
| KVG | Head section adjustment by gas spring | By means of a gas spring (instead of the rod mechanism), operable with one hand; release button on the head section cushion itself. Retrofit not possible. | Factory option |
| LR-75 | Wheel set | Ø 75 mm — Four swivel castors, two of them fully lockable. | Accessory |
| LR-125 | Wheel set | Ø 125 mm — Four swivel castors, two of them fully lockable. | Accessory |
| LR/Z-125 | Central locking castor system | Twin castors Ø 125 mm — mobility with central locking; the four castors are connected by rods, pedals arranged diagonally at the head and foot ends, with colour marking (green = ready to move, red = locked). Retrofit not possible. | Factory option |
| OPS-40/A | Standard rails (pair) | Approx. 400 mm long — CrNi steel, approx. 25 x 10 mm, for mounting on the upholstery frame, with 2 (or 3) spacers. Retrofit not possible. | Factory option |
| OPS-60/A | Standard rails (pair) | Approx. 600 mm long — CrNi steel, approx. 25 x 10 mm, for mounting on the upholstery frame, with 2 (or 3) spacers. Retrofit not possible. | Factory option |
| OPS-100/A | Standard rails (pair) | Approx. 1000 mm long — CrNi steel, approx. 25 x 10 mm, for mounting on the upholstery frame, with 2 (or 3) spacers. Retrofit not possible. | Factory option |
| OPS-140/A | Standard rails (pair) | Approx. 1400 mm long — CrNi steel, approx. 25 x 10 mm, for mounting on the upholstery frame, with 2 (or 3) spacers. Retrofit not possible. | Factory option |
| OPS-170/A | Standard rails (pair) | Approx. 1,700 mm in length — CrNi steel, approx. 25 x 10 mm, for mounting on the upholstery frame, with 2 (or 3) spacers. Retrofit installation is not possible. | Factory option |
| P-2065/A | Paper roll holder | For 650 mm stretcher — chrome-plated, comprising two supports, two forceps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
| P-2080/A | Paper roll holder | For 800 mm stretcher — chrome-plated, comprising two supports, two forceps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
Note: the frame in the tables refers only to the upholstery frame. The lower frame is only available in a lacquered finish. The lateral guide swivel mechanism (Ref. SG-3000/1) is operated like that of the RM patient transport table Ref. H-AWL 3065/Y 980VA.
4. Equivalences and Cross-References
The references H-U …/EE 850 (width 650 mm) and H-EKG …/EE 850 (width 800 mm) belong to the same AGA-DUO-LIFT family from the manufacturer AGA Sanitätsartikel and differ only in the frame finish (lacquered, chrome-plated or stainless steel). There is no official cross-reference table published by AGA relating this series to codes from other manufacturers; market alternatives are compared by category and require field-by-field verification.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Italian brand (manufactured in Italy) | LORD — examination couch with electric columns and TR/RTR | 44510 (water green) / 44516 (colour to choose) · SKU Cahnos GM44510 / GM44516 | Comparable by category (not interchangeable 1:1) | Two electric columns with height 52-94 cm and Trendelenburg/reverse TR positions; load 200 kg; dimensions 194 x 68 cm. Differs: higher height and load range, cushion tilt by gas spring and no option for stainless steel frame. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Other brands in the sector (e.g. Malvestio, Promotal, Meden-Inmed or Favero, among European manufacturers of 2-section electric examination couches with Trendelenburg) market similar ranges, but their codes must be verified against each manufacturer’s official technical data sheet before any substitution.
5. Selection tips and variants of interest
- Choose the width according to the activity: 650 mm (ref. H-U …) for general consultations and 800 mm (ref. H-EKG …) if a larger surface is required for cardiology, stress tests or patients of large build.
- Select the frame finish: lacquered (economical), chrome-plated (classic aesthetics) or stainless steel (maximum hygiene and corrosion resistance, recommended for humid environments or intensive disinfection). The lower frame is always lacquered.
- Check the space and electrical installation: the table is 1,900 mm long; for the power supply, it is recommended to have a mains socket (ideally floor-mounted) in the area of the stretcher.
- Configure the accessories at the factory: the facial orifice (GS-1710), the headrest adjustment by gas spring (KVG), the wheel system with central brake (LR/Z-125) and the standardised rails (OPS-…) are not retrofittable: define them at the time of purchase if you need them.
- For mobility on the ward: consider the wheel sets LR-75 or LR-125; for facilities with frequent transfers, the LR/Z-125 system with centralised brake and colour marking facilitates safe locking of the equipment.

















Reviews