Description
Trolley for waste or dirty laundry series WZMR – TECH-MED
1. Presentation
The trolley for waste or dirty laundry from the WZMR series by TECH-MED is the ideal solution for hospitals and diagnostic imaging centres that need to remove waste, textiles and dirty laundry safely within the MRI room. Manufactured entirely from non-magnetic materials, it allows the collection of bags of up to 120 litres without interfering with the magnetic field of the equipment, protecting patients, healthcare staff and the scanner itself. An essential complement to the radiology workflow, available in single, double and triple versions to suit any space and workload.
2. Technical explanation
The WZMR series is constructed from non-magnetic materials (aluminium and ABS) for use in the MRI room. The aluminium frame is powder-coated in grey RAL 7035 and is prepared for extension with additional segments, allowing the trolley’s capacity to be adapted to the needs of the department. The lid, made of powder-coated grey RAL 7035 aluminium or grey ABS plastic, is raised manually. The ring incorporates clips that prevent the bag from slipping, and the trolley moves on non-magnetic wheels of ø75 mm, two of which have brakes to ensure stability. Being free of ferromagnetic components, the trolley does not experience magnetic attraction or affect image quality, and is suitable for use in rooms with scanners up to 3T inclusive.
3. Technical Specifications
Product details
- Frame: made of aluminium, powder-coated in grey (RAL 7035), prepared for extension with additional segments.
- Lid: of powder-coated grey aluminium (RAL 7035) or grey ABS plastic, manually raised.
- Ring: equipped with clips that prevent the bag from slipping.
- Non-magnetic wheels: diameter ø75 mm, includes two with brakes.
Dimensions table for the WZMR series
| Type | Bag capacity [l] | Width [mm] | Depth [mm] | Height [mm] | Trolley type |
|---|---|---|---|---|---|
| WZ-1/60MR | 60-80 | 355 | 410 | 680 | single |
| WZ-1/100MR | 100-120 | 410 | 465 | 850 | single |
| WZ-2/40MR | 40 | 315 | 385 | 520 | single |
| WZ-2/60MR | 60-80 | 390 | 440 | 680 | single |
| WZ-2/100MR | 100-120 | 445 | 495 | 850 | single |
| WZ2-1/60MR | 60-80 | 760 | 410 | 680 | double |
| WZ2-1/100MR | 100-120 | 865 | 465 | 850 | double |
| WZ2-2/60MR | 60-80 | 790 | 440 | 680 | double |
| WZ2-2/100MR | 100-120 | 900 | 495 | 850 | double |
| WZ3-1/60MR | 60-80 | 1155 | 410 | 680 | triple |
| WZ3-1/100MR | 100-120 | 1320 | 465 | 850 | triple |
| WZ3-2/60MR | 60-80 | 1190 | 440 | 680 | triple |
| WZ3-2/100MR | 100-120 | 1355 | 495 | 850 | triple |
Available models (manufacturer references)
| Commercial model | Manufacturer reference / index |
|---|---|
| WZ-2/100MR | WZ-01-R(AL)-100-K6.6-MR |
| WZ2-2/100MR | WZ-02-R(AL)-100-K6.6-MR |
| WZ3-2/100MR | WZ-03-R(AL)-100-K6.6-MR |
Attention! The trolleys for waste or dirty laundry from the WZMR series can be used in the MRI room with a power of up to 3T inclusive. Use of the product in MRI rooms of higher power is prohibited.
4. Equivalences and Cross-References
This item belongs to the family of non-magnetic trolleys from TECH-MED (ZTM TECH-MED Sp. z o.o.) and is identified in our catalogue by the SKU TMD5260. The manufacturer references WZ-01-R(AL)-100-K6.6-MR, WZ-02-R(AL)-100-K6.6-MR and WZ-03-R(AL)-100-K6.6-MR correspond respectively to the single, double and triple versions of 100-120 l. No direct equivalents with other manufacturers are indicated as we do not have confirmation from reliable sources; to check compatibilities or custom configurations, please consult our sales team.
5. Selection tips and variants of interest
When choosing the most suitable WZMR trolley, consider the daily volume of waste and the space available in the room. For low volumes or confined spaces, the single versions (40-120 l) are the most practical; for radiology departments with high volume or less frequent collections, the double (WZ2) or triple (WZ3) configurations multiply the useful capacity. The 100-120 l models offer greater height (850 mm) and capacity, while the 60-80 l versions are more manageable. Always check that the scanner power does not exceed 3T and take advantage of the extendable frame to add segments if the department’s needs grow over time. Consult our team for specific configurations or queries about accessories.








Reviews
There are no reviews yet.