Articulating replacement reload 30 mm for endoscopic linear stapler – Titanium staples 2.5 mm, white colour (Ref. WZULS-P2-30-2.5)

150,00 €

Articulating replacement reload of 30 mm for endoscopic linear surgical stapler, with titanium staples of 2.5 mm height and white colour (fine tissue). Indicated for resection, anastomosis and transection of the gastrointestinal tract in laparoscopic surgery. Traceable reference: WZULS-P2-30-2.5.

International shipping. Import duties and taxes are payable by the recipient.

Reference
WZULS-P2-30-2.5

Description

1. Reliable reload for digestive laparoscopic surgery

Keep your endoscopic linear surgical stapler always operational with this articulating replacement reload of 30 mm, with titanium staples of 2.5 mm height and white colour. Designed for the professional who demands consistent results, it guarantees a safe and homogeneous mechanical suture line, with good haemostasis and a reproducible closure in every procedure on fine tissue of the gastrointestinal tract.

New product, sterile and single-use, with traceable reference for warehouse control and management of operating theatre consumables. The articulation of the distal end facilitates access and manoeuvrability in reduced-space cavities.

2. How it works: articulating reload with “B” closure

The endoscopic linear stapler (laparoscopic endocutter) simultaneously places several rows of staples and cuts the tissue between them. This reload incorporates the articulating end, which allows the stapling head to be oriented to the desired angle without moving the handle, improving the approach in digestive surgery (stomach, small intestine, colon and rectum).

The medical-grade titanium staples close in a “B” shape, the classic indicator of a reliable mechanical suture, with good tissue perfusion and vascular sealing. The white colour unambiguously identifies the lowest-height configuration in the range, indicated for fine tissue.

3. Technical Specifications

Staple line length 30 mm
Staple height (open) 2.5 mm
Identification colour White (fine tissue)
Load type Articulating
Staple material Titanium (medical grade)
Staple closure shape “B” closure
Use Single-use, sterile
Applications Resection, anastomosis and transection of the gastrointestinal tract
Compatibility WZULS handle/shaft system (line lengths 30, 45 and 60 mm; shaft diameter 12 mm)
Distributor reference WZULS-P2-30-2.5

WZULS family table (length 30 mm)

Series Geometry Height / Colour Reference Cahnos
WZULS-P1 Straight reload 2.5 mm – White WZULS-P1-30-2.5
WZULS-P2 Articulating cartridge 2.5 mm – White WZULS-P2-30-2.5 (this reference)
WZULS-P3 Triple reload 2.0 / 2.5 / 3.0 mm – Brown WZULS-P3-30B-2.0,2.5,3.0
WZULS-P3 Triple reload 3.0 / 3.5 / 4.0 mm – Purple WZULS-P3-30P-3.0,3.5,4.0

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer for this generic reload. Below are real market references with comparable specifications, classified as comparable by category (same clinical function and configuration, but with proprietary handle systems: they are not interchangeable 1:1).

Manufacturer / Brand Reference Equivalence level Technical differences / Remarks
Medtronic / Covidien (Endo GIA Universal Articulating) 030451 Comparable by category Articulating reload of 30 mm, white, staple 2.5 mm for fine tissue. Same philosophy of white articulating 30 mm reload, but proprietary Endo GIA system: not interchangeable 1:1.
Covidien / Medtronic (Multifire Endo GIA) 030805L Comparable by category White 30-2.5 mm reload for classic Endo GIA system. Proprietary system: not interchangeable 1:1.
Ethicon (ECHELON FLEX ENDOPATH / GST) White GST 2.6 mm (GST45W series and equivalents) Comparable by category White cartridge for fine tissue (approximate open height 2.6 mm), GST+B-Form technology with single staple height. There is no standard 30 mm version in this family: not interchangeable 1:1.
Generic manufacturers of endoscopic loads (market) White articulating 30 mm 2.5 mm reload Comparable by category Equivalent specification (30 mm, white, 2.5 mm, articulating) in generic reloads; without a unified public reference, verify with each supplier.

Notice: the reference WZULS-P2-30-2.5 corresponds to the distributor’s own nomenclature (WZULS-P2: endoscopic articulating reload line; 30: length 30 mm; 2.5: staple height 2.5 mm). No equivalent manufacturer code confirming this construction has been found in public sources; verify it with the technical department before including it in tender specifications.

5. Selection tips and variants of interest

The staple height must be chosen according to the thickness of the tissue to be treated: fine tissue with small heights and thick or dense tissue with large heights. The white 2.5 mm reload is associated with fine tissue and is the lowest-height option in the WZULS single-height range.

  • Fine tissue: white articulating 2.5 mm reload (this reference, WZULS-P2-30-2.5) or straight reload WZULS-P1-30-2.5 if articulation is not required.
  • Fine-vascular tissue: brown triple reload 2.0 / 2.5 / 3.0 mm (WZULS-P3-30B-2.0,2.5,3.0).
  • Medium-thick tissue: purple triple reload 3.0 / 3.5 / 4.0 mm (WZULS-P3-30P-3.0,3.5,4.0).

If your portfolio needs stapling lines of 45 or 60 mm, the WZULS series offers single-height variants (P1/P2) and triple reload (P3) in those lengths. The WZULS series reloads combine with the 30, 45 and 60 mm endoscopic handles (shaft diameter 12 mm) to provide a complete laparoscopic mechanical suture system. For any compatibility doubt or for use in tenders, consult our technical department.

Additional information

Reference

WZULS-P2-30-2.5

Staple line length

30 mm

Staple height

2.5 mm

Identification colour

White (fine tissue)

Load type

Articulating

Staple material

Titanium (medical grade)

Closure shape

B-shaped closure

Use

Single-use, sterile

Application

Resection, anastomosis and transection of the gastrointestinal tract

Compatibility

WZULS handle/shaft system (shaft diameter 12 mm)

Sterilisation

Yes, sterile (single-use)

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Articulating replacement reload 30 mm for endoscopic linear stapler – Titanium staples 2.5 mm, white colour (Ref. WZULS-P2-30-2.5)”

Your email address will not be published. Required fields are marked *