We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reloadable Linear Cutting Stapler 100 Titanium Staples 0.20 x 4.2 mm – Simultaneous Suture and Cutting (WZCTS-A-100H)

150,00 €

Reloadable linear cutting stapler with 100 titanium staples of 0.20 mm diameter and 4.2 mm staple height, factory reference WZCTS-A-100H. It applies two rows of interlocking staples on each side and sutures and cuts tissue simultaneously, with a reinforced stainless steel main anvil beam. Its stapled line is 50% longer than the cutting line, reducing the risk of anastomotic leakage. Reloadable design: accepts up to 5 load changes in the same procedure, optimising cost per procedure. Ideal for anastomoses, resections and closures in digestive, colorectal and urology surgery. Compatible load: WZCTS-P1-100H.

International shipping. Import duties and taxes are payable by the recipient.

Reference
WZCTS-A-100H

Description

1. Introduction

The reloadable linear cutting stapler WZCTS-A-100H is a mechanical suturing instrument designed for demanding open surgery. Its double row of titanium staples with integrated cutting allows the surgeon to suture and divide tissue in a single action, reducing operating theatre times and improving anastomosis safety. It is supplied sterile, ready to use, and its reloadable design allows the handle to be used cost-effectively with up to five loads in a single procedure.

2. Technical explanation

The stapler places four rows of interlocking titanium staples (two on each side) while an integrated blade divides the tissue between the two double rows. The main anvil beam is made of reinforced stainless steel, ensuring uniform distribution of compression force along the entire suture line and consistent staple formation even in thick tissue. The stapled line is approximately 50% longer than the cutting line, a safety margin that reduces tension at the ends and minimises the risk of anastomotic leakage. The reload system incorporates a distal positioning device and an acoustic signal that confirms correct seating of the load before firing.

3. Technical Specifications

Characteristic Value
Factory reference WZCTS-A-100H
Manufacture Own (Cahnos)
Staple diameter 0.20 mm (φ0.2 ± 0.02 mm)
Staple height 4.2 mm (± 0.2 mm)
Staple count 100
Staple material Titanium
Material of the main anvil beam Reinforced stainless steel
Staple arrangement Double interlocking line on each side of the cutting line
System Simultaneous cutting and suturing
Loading system Reloadable, up to 5 reloads in the same surgery
Compatible cartridge WZCTS-P1-100H
Sterilisation Sterilised by radiation (sterile)
Certifications CE, ISO 13485, SGS; international registrations (including AEMPS Spain)
Applications Digestive, abdominal, colorectal, urology and anorectal surgery

WZCTS-A range (data from the manufacturer’s catalogue)

Model Number of staples Diameter (mm) Height (mm) Approx. total length (mm)
WZCTS-A-60L / M / H 60 0.2 ± 0.02 2.5 / 3.8 / 4.2 ± 0.2 265 ± 4.0
WZCTS-A-80L / M / H 80 0.2 ± 0.02 2.5 / 3.8 / 4.2 ± 0.2 280
WZCTS-A-100L / M / H 100 0.2 ± 0.02 2.5 / 3.8 / 4.2 ± 0.2 Specification to be confirmed with the manufacturer’s technical data sheet

Note: the staple height indicated by the manufacturer in its official table is 4.2 mm (±0.2 mm) for model H. The corresponding replacement load for this unit is reference WZCTS-P1-100H.

4. Equivalences and Cross-References

The code WZCTS-A-100H has been verified against manufacturer and authorised distributor documentation (product catalogue and HSA Singapore regulatory database). It is confirmed as an official reference identical to the factory reference.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands. Therefore, alternatives from other manufacturers should be considered comparable at category level, not interchangeable 1:1, and require verification of load and geometry compatibility before use in tenders:

  • Purple Surgical – Ultimate Reloadable Linear Cutter: same category (reloadable linear cutting stapler with staggered double rows of titanium and simultaneous cutting). Verify staple heights and load system.
  • Ethicon (J&J MedTech) – PROXIMATE™ Linear Cutter / linear platform: comparable by category; they differ in proprietary load system, anvil geometry and staple heights (3.8 / 4.8 mm).
  • Medtronic – GIA™ / Endo GIA™ with DST technology: comparable by category for anastomoses and resections; reloadable with proprietary system, not compatible with loads.
  • LEPU Medical, Victor Medical, Stapleline, Volkmann Med: manufacturers with reloadable titanium linear cutting staplers. Comparable by category; check dimensions, material and regulatory classification in each data sheet.

Pending confirmation with the manufacturer/distributor: the exact total length of model WZCTS-A-100H and any official cross-reference table. Before replacing this reference with another brand in a tender, consult the technical department.

5. Selection tips and variants of interest

Choose the staple height according to tissue thickness: L (2.5 mm) models are reserved for thin tissue, M (3.8 mm) for standard tissue and H (4.2 mm), like this unit, for thick or oedematous tissue. At Cahnos we offer the same range in presentations of 60, 80 and 100 staples and in heights 3.8 and 4.2 mm:

  • Same parameters, height 3.8 mm: WZCTS-A-100M, WZCTS-A-80M, WZCTS-A-60M.
  • Height 4.2 mm in other capacities: WZCTS-A-80H, WZCTS-A-60H.
  • Replacement loads (spare parts): WZCTS-P1-60H, WZCTS-P1-80H, WZCTS-P1-100H and M versions.

To equip a surgical department, we recommend combining the stapler with its replacement loads WZCTS-P1-100H and planning stock according to the number of firings per procedure. Sterile single-use product, with an indicated shelf life of 3 years; check the integrity of the sterile packaging before each use.

Additional information

Manufacturer reference model

WZCTS-A-100H

Product type

Reloadable linear cutting stapler (reloadable linear cutter)

Staple diameter

0.20 mm (φ0.2 ± 0.02 mm)

Staple height

4.2 mm (± 0.2 mm)

Staple count

100

Staple arrangement

Double row of interlocking staples on each side of the cutting line

Staple material

Titanium

Anvil beam material

Reinforced stainless steel

System

Simultaneous cutting and suturing

Loading system

Reloadable, up to 5 loads in the same surgery

Compatible cartridge

WZCTS-P1-100H

Sterilisation

Sterilised by radiation (sterile)

Presentation

Sterile single-use unit with reload system

Certifications

CE, ISO 13485, SGS; international registrations (AEMPS Spain among others)

Application

Digestive, abdominal, colorectal, urology and anorectal surgery

Reviews

There are no reviews yet.

Be the first to review “Reloadable Linear Cutting Stapler 100 Titanium Staples 0.20 x 4.2 mm – Simultaneous Suture and Cutting (WZCTS-A-100H)”

Your email address will not be published. Required fields are marked *