Description
1. Commercial Introduction
The disposable haemorrhoidal stapler KHPH-34 is a single-use circular mechanical suturing instrument designed for haemorrhoidopexy and selective mucosal resection at the dentate line (haemorrhoidal prolapse surgery). With a length of 395 mm and an external diameter of 34 mm, it offers ergonomic handling and adequate reach for the anal canal, in both scheduled and emergency procedures. Each unit is supplied sterile and ready for the operating theatre, eliminating the risks of cross-contamination and simplifying logistics for the general and digestive surgery department. It is an excellent value-for-money alternative to the premium PPH sets on the market, while maintaining the same technical principle: a double circular row of staples with an integrated annular blade.
2. Technical explanation of the equipment and procedure
The KHPH-34 haemorrhoidal stapler is based on the principle of the PPH technique (Procedure for Prolapse and Haemorrhoids). The instrument provides two interlocking staple loops that form a secure circular suture line; the internal annular blade then cuts off the excess tissue, creating a clean, uniform circular anastomosis. Its mechanism allows an adjustable thickness, ensuring a minimum suture gap adapted to mucosal thickness and preventing injury from excessive pressure. The staple density is optimised to reduce postoperative bleeding and promote faster, more comfortable patient recovery. The PPH-type set is usually completed with an anoscope, anal dilator and purse-string suture for correct traction and positioning of the mucosa before firing.
3. Technical Specifications
Features of the disposable haemorrhoidal stapler KHPH-34 (data from the distribution data sheet; always verify the batch label):
| Parameter | Value |
| Reference / SKU | KHPH-34 |
| Type | Disposable circular haemorrhoidal stapler (PPH technique) |
| Total length | 395 mm |
| Outer diameter | 34 mm |
| Staple height | 3.8 mm |
| Staple diameter (wire) | 0.28 mm |
| Staple arrangement | Two interlocking circular loops/rows (double staggered) |
| Staple material | Titanium |
| Cutting system | Internal annular blade |
| Closure adjustment | Adjustable closure height according to tissue thickness |
| Number of staples | 32 (usual 34 mm format in the PPH range; confirm on the batch label) |
| Use | Single-use (disposable) |
| Sterilisation | Sterile, individually packaged |
| Application | Haemorrhoidopexy; selective mucosal resection at the dentate line (haemorrhoidal prolapse) |
KHPH family table (calibre variants available at Cahnos):
| Reference | External diameter (mm) | Length (mm) | Staple height (mm) | Staple wire Ø (mm) |
| KHPH-32 | 32 | 395 | 3.8 | 0.28 |
| KHPH-33 | 33.5 | 395 | 3.8 | 0.28 |
| KHPH-34 | 34 | 395 | 3.8 | 0.28 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing this code with the codes of the major manufacturers. The KHPH-34 code is Cahnos’s own distribution reference for the 34 mm PPH range; the following references are offered as a functional category comparison verified against public sources from each manufacturer, never as 1:1 interchangeable equivalents:
| Manufacturer / Brand | Model / Reference | Diameter | Main characteristics | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | PROXIMATE™ PPH03 | 33 mm | 28 staples; closed height 0.75–1.5 mm; blade Ø 24.4 mm; PPH set with anoscope | Comparable by category | Ø 33 vs 34 mm; premium set with dilator and purse-string suture |
| Medtronic (Covidien) | EEA™ Hemorrhoid & Prolapse Set HEM3335 | 33 mm | 32 DST™ titanium staples; staple height 3.5 mm | Comparable by category | Ø 33 vs 34 mm; staple height 3.5 vs 3.8 mm; shaft 12 cm |
| GoldenStapler | PPHD34 | 34 mm | Blade Ø 26 mm; 32 titanium staples; set with anoscopes | Functionally comparable | Same external Ø of 34 mm; verify staple height and IFU |
| Lantex | CPH34 (PPH03 format) | 34 mm | PPH-type haemorrhoidal set of 34 mm | Functionally comparable | Verify number of staples and closed height in the IFU |
| F+Plussurgical | CPH34HV (high volume) | 34 mm | 32 staples; open height 4.2 mm / closed 0.75–1.6 mm | Comparable by category | Greater open height (4.2 vs 3.8 mm) |
| Cousin (France) | CPH | — | Circular stapler for rectal and haemorrhoidal prolapse | Comparable by category | European range; consult references and set accessories |
Important: there is no manufacturer-validated equivalence table declaring these models to be interchangeable 1:1. Before substituting in a procedure or tender, the surgery department must verify diameters, staple height, number of staples and accessories in the official technical data sheet and in each manufacturer’s IFU. Any comparison between brands must be reviewed field by field: exact dimensions, staple material, open/closed height, single-use and regulatory classification of the actual product.
5. Selection tips and variants of interest
- Calibre selection: for anal canals with a smaller lumen, the smaller diameters of the same family are recommended: KHPH-32 (32 mm) and KHPH-33 (33.5 mm), all with lengths of 395 mm and staples of 3.8 mm / 0.28 mm. The KHPH-34 (34 mm) model is indicated for patients with a larger anatomical calibre.
- Mucosal thickness: always adjust the closure height using the adjustment nut according to tissue thickness; a staple that is too high in thin tissue can cause excessive pressure, whereas one that is too low compromises haemostasis.
- Accessory set: confirm that the presentation includes anoscope, dilator and purse-string suture if your PPH protocol requires it; if not, consider purchasing them separately.
- Pre-firing verification: check the sterility seal, the safety button and the correct fitting of the anvil before closing. The device is single-firing and cannot be reloaded.
- Regulatory: confirm the CE marking and MDR classification on the batch label before using it in technical specifications; the regulatory classification must be verified on the actual product, not assumed.








Reviews