We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Haemorrhoidal Stapler 34 mm (KHPH-34) | Length 395 mm | Titanium Staples 3.8 mm Ø 0.28 mm | PPH Technique

150,00 €

The disposable haemorrhoidal stapler KHPH-34 (external diameter 34 mm, length 395 mm) performs haemorrhoidopexy according to the PPH technique: it places two interlocking loops of titanium staples (height 3.8 mm, wire 0.28 mm) and, by means of its internal annular blade, removes excess tissue to create a circular anastomosis. Its adjustable thickness minimises pressure on the mucosa and its staple density reduces postoperative bleeding. Sterile single-use instrument, indicated for selective mucosal resection at the dentate line and haemorrhoidal prolapse surgery. Ideal for the operating theatre, hospital purchasing and proctology tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
KHPH-34

Description

1. Commercial Introduction

The disposable haemorrhoidal stapler KHPH-34 is a single-use circular mechanical suturing instrument designed for haemorrhoidopexy and selective mucosal resection at the dentate line (haemorrhoidal prolapse surgery). With a length of 395 mm and an external diameter of 34 mm, it offers ergonomic handling and adequate reach for the anal canal, in both scheduled and emergency procedures. Each unit is supplied sterile and ready for the operating theatre, eliminating the risks of cross-contamination and simplifying logistics for the general and digestive surgery department. It is an excellent value-for-money alternative to the premium PPH sets on the market, while maintaining the same technical principle: a double circular row of staples with an integrated annular blade.

2. Technical explanation of the equipment and procedure

The KHPH-34 haemorrhoidal stapler is based on the principle of the PPH technique (Procedure for Prolapse and Haemorrhoids). The instrument provides two interlocking staple loops that form a secure circular suture line; the internal annular blade then cuts off the excess tissue, creating a clean, uniform circular anastomosis. Its mechanism allows an adjustable thickness, ensuring a minimum suture gap adapted to mucosal thickness and preventing injury from excessive pressure. The staple density is optimised to reduce postoperative bleeding and promote faster, more comfortable patient recovery. The PPH-type set is usually completed with an anoscope, anal dilator and purse-string suture for correct traction and positioning of the mucosa before firing.

3. Technical Specifications

Features of the disposable haemorrhoidal stapler KHPH-34 (data from the distribution data sheet; always verify the batch label):

Parameter Value
Reference / SKU KHPH-34
Type Disposable circular haemorrhoidal stapler (PPH technique)
Total length 395 mm
Outer diameter 34 mm
Staple height 3.8 mm
Staple diameter (wire) 0.28 mm
Staple arrangement Two interlocking circular loops/rows (double staggered)
Staple material Titanium
Cutting system Internal annular blade
Closure adjustment Adjustable closure height according to tissue thickness
Number of staples 32 (usual 34 mm format in the PPH range; confirm on the batch label)
Use Single-use (disposable)
Sterilisation Sterile, individually packaged
Application Haemorrhoidopexy; selective mucosal resection at the dentate line (haemorrhoidal prolapse)

KHPH family table (calibre variants available at Cahnos):

Reference External diameter (mm) Length (mm) Staple height (mm) Staple wire Ø (mm)
KHPH-32 32 395 3.8 0.28
KHPH-33 33.5 395 3.8 0.28
KHPH-34 34 395 3.8 0.28

4. Equivalences and Cross-References

There is no manufacturer-validated equivalence table cross-referencing this code with the codes of the major manufacturers. The KHPH-34 code is Cahnos’s own distribution reference for the 34 mm PPH range; the following references are offered as a functional category comparison verified against public sources from each manufacturer, never as 1:1 interchangeable equivalents:

Manufacturer / Brand Model / Reference Diameter Main characteristics Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) PROXIMATE™ PPH03 33 mm 28 staples; closed height 0.75–1.5 mm; blade Ø 24.4 mm; PPH set with anoscope Comparable by category Ø 33 vs 34 mm; premium set with dilator and purse-string suture
Medtronic (Covidien) EEA™ Hemorrhoid & Prolapse Set HEM3335 33 mm 32 DST™ titanium staples; staple height 3.5 mm Comparable by category Ø 33 vs 34 mm; staple height 3.5 vs 3.8 mm; shaft 12 cm
GoldenStapler PPHD34 34 mm Blade Ø 26 mm; 32 titanium staples; set with anoscopes Functionally comparable Same external Ø of 34 mm; verify staple height and IFU
Lantex CPH34 (PPH03 format) 34 mm PPH-type haemorrhoidal set of 34 mm Functionally comparable Verify number of staples and closed height in the IFU
F+Plussurgical CPH34HV (high volume) 34 mm 32 staples; open height 4.2 mm / closed 0.75–1.6 mm Comparable by category Greater open height (4.2 vs 3.8 mm)
Cousin (France) CPH — Circular stapler for rectal and haemorrhoidal prolapse Comparable by category European range; consult references and set accessories

Important: there is no manufacturer-validated equivalence table declaring these models to be interchangeable 1:1. Before substituting in a procedure or tender, the surgery department must verify diameters, staple height, number of staples and accessories in the official technical data sheet and in each manufacturer’s IFU. Any comparison between brands must be reviewed field by field: exact dimensions, staple material, open/closed height, single-use and regulatory classification of the actual product.

5. Selection tips and variants of interest

  • Calibre selection: for anal canals with a smaller lumen, the smaller diameters of the same family are recommended: KHPH-32 (32 mm) and KHPH-33 (33.5 mm), all with lengths of 395 mm and staples of 3.8 mm / 0.28 mm. The KHPH-34 (34 mm) model is indicated for patients with a larger anatomical calibre.
  • Mucosal thickness: always adjust the closure height using the adjustment nut according to tissue thickness; a staple that is too high in thin tissue can cause excessive pressure, whereas one that is too low compromises haemostasis.
  • Accessory set: confirm that the presentation includes anoscope, dilator and purse-string suture if your PPH protocol requires it; if not, consider purchasing them separately.
  • Pre-firing verification: check the sterility seal, the safety button and the correct fitting of the anvil before closing. The device is single-firing and cannot be reloaded.
  • Regulatory: confirm the CE marking and MDR classification on the batch label before using it in technical specifications; the regulatory classification must be verified on the actual product, not assumed.

Additional information

Reference

KHPH-34

Product type

Disposable circular haemorrhoidal stapler (PPH technique)

Total length mm

395

External diameter mm

34

Staple height mm

3.8

Staple wire diameter mm

0.28

Staple material

Titanium

Staple arrangement

Two interlocking circular loops (double staggered)

Number of staples

32 (34 mm standard PPH format; confirm on label)

Cutting system

Internal annular blade

Closure adjustment

Adjustable closure height according to tissue thickness

Use

Single-use (disposable)

Sterilisation

Sterile, individually packaged

Presentation

Sterile unit

Application

Haemorrhoidopexy; selective mucosal resection at the dentate line (haemorrhoidal prolapse)

Reviews

There are no reviews yet.

Be the first to review “Disposable Haemorrhoidal Stapler 34 mm (KHPH-34) | Length 395 mm | Titanium Staples 3.8 mm Ø 0.28 mm | PPH Technique”

Your email address will not be published. Required fields are marked *