We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Medium ACR Phantom for MRI | Diameter 178 mm, Calibration and Quality Control | Ref. CAHIRM6007

Price on request

Medium ACR phantom for magnetic resonance imaging with a cylinder 178 mm in diameter and 15.6 cm in height, approved by the American College of Radiology (ACR). It incorporates internal reference structures (perforated plate, cylinders, resolution blocks and signal-to-noise chamber) and marking points for the nose and chin, ideal for acceptance tests, constancy tests and accreditation of MRI equipment. Compatible with standard ACR supports and cradles for Siemens, Philips, General Electric, Canon and Hitachi. Reference CAHIRM6007, equivalent to the 7\” Medium ACR models from Marketlab, Newmatic Medical and allMRI.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAHIRM6007

You will also find it in

Description

Guaranteed diagnostic quality in your MRI suite

The medium ACR MRI phantom is the reference instrument for quality control, calibration and accreditation programmes for MRI equipment. Approved by the American College of Radiology (ACR), it allows objective and repeatable verification that your equipment maintains a constant diagnostic image quality, in accordance with international standards. A professional, robust and ready-to-use solution, designed for hospitals, diagnostic imaging clinics and reference centres.

How this medium ACR phantom works and what it evaluates

The medium ACR phantom is a hollow cylinder made of acrylic, hermetically sealed, whose interior houses reference structures (perforated plate, cylinders, resolution blocks and signal-to-noise chamber) immersed in a solution of nickel chloride and sodium chloride that stably reproduces the T1 and T2 relaxation properties of biological tissues. With marking points for the nose and chin, it allows the technician and the medical physicist to perform acceptance tests, periodic constancy tests and pre-accreditation checks, evaluating the parameters that determine the image quality of the system:

  • Geometric accuracy and spatial distortion.
  • Spatial resolution and slice thickness.
  • Image homogeneity and signal-to-noise ratio (SNR).
  • Contrast and low-contrast detectability.
  • Slice position and water-fat misregistration.

Technical specifications

Parameter Value
Outer diameter 178 mm (17.8 cm / 7 inches)
Height 156 mm (15.6 cm)
Barrel material Acrylic
Contents Solution of nickel chloride and sodium chloride
Approval American College of Radiology (ACR)
Reference elements Perforated plate, cylinders and internal structures; reference points for nose and chin
Compatibility Supports for Siemens, Philips, General Electric (GE), Canon and Hitachi
Applications Acceptance tests, constancy tests and accreditation of MRI equipment
Reference CAHIRM6007

Equivalences and cross-references

This phantom corresponds to the standard model internationally known as Medium ACR MRI Phantom of 178 mm (7\”), distributed by the main quality control manufacturers in magnetic resonance imaging. Among the most common equivalent references in the sector are: Marketlab 104683, Newmatic Medical 104683, allMRI MRI-6007 (European version, diameter 17.8 cm), allMRI MRI-6810, JRT Associates ACR Medium and Sun Nuclear ACR Medium MRI Accreditation Phantom. It meets the requirements of the ACR accreditation programme and is compatible with the standard ACR phantom cradles on the market.

Selection tips and variants of interest

For full-system ACR accreditation and wide-field tests (head and body), the 203 mm ACR phantom (reference CAHRM6783) is the reference option. If your quality programme focuses on dedicated extremity, knee or breast coils, please consult the 11.43 cm extremity ACR phantom (reference CAHIRM6676). The 178 mm medium model is the recommended intermediate option for equipment with space limitations or intermediate scan volumes. Always keep the phantom in a stable vertical position, avoid impacts and prolonged exposure to extreme temperatures to preserve the stability of the solution. Should you have any questions about compatibility with your equipment or accreditation programmes, our technical-commercial department is at your disposal.

Additional information

Product type

Calibration and quality control phantom for magnetic resonance imaging

Diameter

178 mm (17.8 cm / 7 inches)

Height

156 mm (15.6 cm)

Material

Acrylic cylinder

Contents

Solution of nickel chloride and sodium chloride

Approval

American College of Radiology (ACR)

Internal elements

Perforated plate, cylinders, resolution blocks, signal-to-noise chamber and nose and chin reference points

Compatibility

Siemens, Philips, General Electric (GE), Canon and Hitachi

Application

Acceptance tests, constancy tests and ACR accreditation

Presentacion

Unit

Reviews