Description
Safety and precision in intubation within the MRI room
The PROACT MacIntosh 4 (Mac 4) laryngoscope blade is the reference disposable solution for securing the airway of obese or large adult patients undergoing magnetic resonance imaging diagnostics. Its construction in rigid polymer, completely free of metallic components, eliminates the risk of ferromagnetic projectiles and interference with the magnetic field, allowing a safe and fully operational laryngoscopy set to be maintained within the MRI room. An essential item for radiology departments, operating theatres, emergency departments, anaesthesia and ICUs that work with patients undergoing advanced diagnostic imaging.
Technical explanation of the equipment
Laryngoscopy with a MacIntosh-type blade uses the classic curved profile that allows the base of the tongue to be displaced and the glottis to be visualised directly, facilitating the passage of the endotracheal tube. In size 4, the PROACT blade offers the greatest length in the curved series, adapted to large adult patients or those with deep airway anatomy. It is manufactured from high-strength polycarbonate that resists breakage, bending and torsion during the manoeuvre, even under high loads. Being free of metals and latex, it behaves as an MR conditional device, suitable for use in controlled magnetic resonance areas of up to 3 teslas, always coupled to a PROACT handle with MR condition. It incorporates an atraumatic tip with no sharp edges, an endotracheal tube guide surface along its entire length and shielded optics that concentrate light at the exact point of vision. Its single-use format eliminates sterilisation processes and prevents cross-contamination between patients.
Technical specifications
| Characteristic | Specification |
| Brand | PROACT (PROACT Medical) |
| Model | MacIntosh 4 (Mac 4) |
| Reference | MRHPCMAC4 |
| Type | Disposable laryngoscope blade (single-use) |
| Indication | Obese or large adult patients |
| Material | Rigid polycarbonate polymer, free from metals and latex, biocompatible |
| MRI compatibility | MR conditional up to 3 teslas, tested to ASTM standards (F2052, F2182, F2213, F2219) |
| Regulatory standard | ISO 7376:2009, Green system |
| Compatible handles | PROACT MR conditional handles (Ref. MRGSHB01 / PA-MRGSHB01) |
| Design | Atraumatic tip, profile without sharp edges, endotracheal tube guide along its entire length |
| Optics | Shielded, with concentrated light emission |
| Presentation | Box of 10 units, easy-open individual packaging identifiable for MRI, dispenser box |
| Sterilisation | Does not require reprocessing (single-use) |
| Intended use | Endotracheal intubation in MRI environments |
Equivalences and cross-references
The reference MRHPCMAC4 corresponds to the original PROACT factory code (Mac 4 MR conditional blade, box of 10 units), also marketed as PA-MRHPCMAC4 in the European distribution of the ISSO catalogue. It is the complementary piece for the PROACT MRI handle (Ref. MRGSHB01 in Cahnos, equivalent to PA-MRGSHB01) and works with the additional battery pack (Ref. MRBATT01). It shares a platform with the rest of the PROACT MRI-conditional blades: MacIntosh 1, 2 and 3 (MRHPCMAC1, MRHPCMAC2, MRHPCMAC3) and the straight Miller sizes (MRHPCMIL00, MRHPCMIL0, MRHPCMIL1, MRHPCMIL2, MRHPCMIL3). As a comprehensive alternative for MRI rooms, Cahnos offers the amagnetic laryngoscope kit with handle and set of blades (Ref. R-MN-21).
Selection tips and variants of interest
To configure a complete airway cart in MRI, combine this Mac 4 blade with the PROACT handle (MRGSHB01) and a spare battery pack (MRBATT01). Mac 4 is the usual choice for obese or large adult patients; use Mac 3 for most adults, Mac 1-2 for older paediatric patients and small adults, and the Miller series (00 to 3) for premature infants, neonates and anterior laryngeal anatomies. Always verify that the handle used is the PROACT MRI-conditional model, as the blades in this range are only safe with that specific handle. The presentation in individual packaging identifiable for MRI facilitates stock control and avoids confusion in the MRI room. Consult our technical-commercial team to assess volume needs and special supply conditions.





Reviews
There are no reviews yet.