The laparoscopic suction and irrigation set of Ø 10 mm and 330 mm (ref. ONG299601CST12) allows evacuation of fluids, blood and surgical smoke while irrigating the operative field with physiological saline, maintaining clear endoscopic visibility throughout the procedure. Manufactured from biocompatible and durable materials, it is compatible with 10 mm trocars and standard operating theatre suction and irrigation systems. Single-use disposable instrument presented in a box of 5 units, ideal for hospitals, clinics and surgical centres seeking field control, safety and efficiency in minimally invasive surgery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ONG299601CST12

Description

Introduction

The laparoscopic suction and irrigation set of Ø 10 mm and 330 mm in length (ref. ONG299601CST12) is Cahnos’s solution for combined suction and lavage management in minimally invasive surgery. Its single-connection configuration simplifies assembly, reduces the number of components in the sterile field and integrates seamlessly into standard operating theatre suction and irrigation systems. Manufactured from biocompatible and durable materials, it offers the reliability demanded by hospitals, clinics and surgical centres for optimal fluid control in every procedure. It is the recommended choice for teams seeking a reliable, ergonomic and easy-to-handle instrument for everyday use.

Technical explanation of the device and procedure

This set is introduced through a 10 mm laparoscopic trocar and connected via its standard connection to the central suction system or the surgical suction unit, allowing blood, lavage fluid, surgical smoke or gaseous content to be removed from the abdominal cavity. In turn, the irrigation line allows the operative field to be washed with physiological saline, ensuring clear endoscopic visibility and a clean, stable surgical field at all times.

Its robust and precise construction, with an atraumatic rounded tip and distal placement of the suction ports, protects tissues during manipulation, distributes suction evenly and prevents occlusion or inadvertent aspiration of tissue. The anti-reflective, non-conductive finish of the body ensures optimal visibility under endoscopic light and completely safe handling. The 10 mm calibre provides a higher working flow rate, recommended for procedures requiring high-volume evacuation and irrigation.

Technical specifications

Product technical data sheet

Reference ONG299601CST12
Type Laparoscopic suction and irrigation set
Diameter 10 mm (compatible with 10 mm trocars)
Length 330 mm
Material Biocompatible and durable
Function Simultaneous suction and irrigation
Configuration One connection to the suction and irrigation line
Tip Rounded and atraumatic
Finish Anti-reflective and non-conductive
Use Single-use disposable instrument
Presentation Box of 5 units

Variants of the laparoscopic suction-irrigation family

Reference Configuration Diameter Length Packaging
OR1200S One connection 5 mm 33 cm 12/box
OR1201D Dual connection 5 mm 33 cm 12/box
OR1245S One connection 5 mm 45 cm 12/box
ORC45 Suction-irrigation cannula 5 mm 45 cm 10/box
ONG299601CST12 One connection 10 mm 33 cm 5/box

Equivalences and cross-references

The reference ONG299601CST12 belongs to the range of suction-irrigation cannulas and kits of the Medline Fluid Management family, a reference line for fluid management in laparoscopy. It shares technical configuration with the single-connection set OR1200S (5 mm x 33 cm) and with the longer-reach set OR1245S (5 mm x 45 cm), differing by its larger 10 mm calibre, designed for procedures requiring higher suction and irrigation flow rates. Complementary references in the same family include the dual-connection set OR1201D (5 mm x 33 cm), for independent control of suction and lavage, and the cannula ORC45 (5 mm x 45 cm), which offers the same reach in cannula format. To complete the laparoscopy portfolio, Cahnos also offers Veress insufflation needles ORVN12 and ORVN15 and Yankauer-type surgical suction cannulas (refs. P2000, P20FT and Y240B) for conventional suction systems.

Selection tips and variants of interest

Larger working diameter (ONG299601CST12): this 10 mm set is the recommended option for procedures requiring a larger calibre and higher evacuation and irrigation flow rates, such as surgeries with bleeding or high-volume lavage. Single connection: simpler and lighter configuration, with minimalist assembly in the sterile field for combined suction and lavage management. Dual connection (OR1201D): choose this version if you need to combine suction and lavage independently or have a reserve port without interrupting the main suction. Longer reach (OR1245S and ORC45): recommended for accessing deep areas of the abdominal cavity or for patients with a larger body surface, thanks to their 45 cm length. Consult our technical-commercial team to adjust the selection to your laparoscopy tower, suction system and usual surgical protocol.

Additional information

Reference

ONG299601CST12

Product type

Laparoscopic suction and irrigation set

Configuration

One connection to the suction and irrigation line

Material

Biocompatible and durable

Finish

Anti-reflective and non-conductive

Use

Single-use disposable instrument

Presentation

Box of 5 units

Compatibility

10 mm trocars and standard operating theatre suction and irrigation systems

Family

Medline Fluid Management (laparoscopic suction-irrigation)

Diametro mm

10 mm

Longitud

3.3 cm