Description
1. Introduction
The 35 ml Endoscopic Extraction Bag (SKU WZSRB-A-40) is the reference disposable surgical accessory for the safe retrieval of small-sized specimens and tissue samples in laparoscopic and endoscopic procedures. Its combination of transparent medical-grade polymer and mouth with Ni-Ti (nickel-titanium) shape-memory alloy ensures reliable tissue containment during its extraction through a small incision, protecting the patient against the risk of tumour dissemination, metastasis and heterotopic growth. A device designed for the modern operating theatre: single-use hygiene, clinical safety and ease of handling for the surgical team.
2. Technical explanation of the equipment
The device is mainly composed of an ergonomic actuation handle and a retrieval endobag. The bag is made of transparent and soft medical-grade polymer, with a mouth opening of 40 mm diameter whose edge incorporates a Ni-Ti (nickel-titanium) shape-memory alloy: this feature keeps the mouth open during the manoeuvre, facilitating the introduction of the specimen without additional effort. Once inside, the tissue is automatically secured inside the bag, preventing spills during the extraction path. The ergonomic design of the handle allows comfortable pushing and pulling, and the assembly deploys smoothly through the working channel of the laparoscopic trocar (usual market use: 10–12 mm trocars; confirm deployment before the procedure). Being a single-use device, the risk of cross-contamination between patients is eliminated and traceability in the operating theatre is guaranteed.
3. Technical Specifications
The main technical features of the 35 ml endoscopic extraction bag are detailed below:
| Capacity | 35 ml |
| Mouth diameter | 40 mm |
| Bag material | Transparent, soft medical-grade polymer |
| Mouth coating | Ni-Ti memory alloy (nickel-titanium) |
| Configuration | Ergonomic handle + endobag with self-opening mouth |
| Type of use | Disposable, single-use |
| Working channel (standard use) | 10–12 mm trocars (confirm deployment before the procedure) |
| SKU Cahnos | WZSRB-A-40 |
WZSRB range of endoscopic extraction bags (family references)
| SKU | Capacity | Dimensions |
| WZSRB-A-40 | 35 ml | Diameter 40 mm |
| WZSRB-A-60 | 80 ml | Diameter 60 mm |
| WZSRB-B-80 | 250 ml | Short shaft 82 mm / long shaft 92 mm |
| WZSRB-B-100 | 350 ml | Short shaft 103 mm / long shaft 115 mm |
| WZSRB-B-130 | 1000 ml | Short shaft 118 mm / long shaft 154 mm |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references this reference with the official codes of other brands; consult the technical department before using this information in a tender. At product category level, this 35 ml bag is comparable by category, not interchangeable 1:1, with the following specimen retrieval systems on the market:
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ENDOPOUCH RETRIEVER™ | POUCH 224 ml (4\” x 6\”, 10 mm) | Comparable by category | Transparent self-opening polyurethane bag with support arms; larger volume (224 ml) and format for 10 mm trocar. |
| Medtronic | Endo Catch II (Specimen Retrieval System) | 173049 (approx. 190 cc) | Comparable by category | Polyurethane bag with long cylindrical tube and rigid plastic rod; insertion via 15 mm cannula; mouth geometry and material different from the Ni-Ti alloy. |
| Medline (range MED-LAP) | Extraction Bag / Specimen Retrieval Bag | 100200 / 100400 / 100800 | Comparable by category | Preloaded bag with insertion sleeve and pusher, opening by self-opening wire; opening material and dimensions different from the Ni-Ti alloy; much larger capacities. |
| LEPU Medical | Disposable Endo Retrieval Bag | Types A, B and C | Comparable by category | Bag in polyester or polyurethane depending on type; self-expanding system; same Ni-Ti coating or same dimensions are not confirmed. |
| CONMED | Nylon Specimen Bags | Own range | Comparable by category | Nylon bag for capturing specimens and calculi; different material and opening mechanism. |
| Teleflex / Weck | MemoBag® | Own range | Pending confirmation | Preloaded bag with simple deployment; confirm capacity, material and trocar compatibility in the manufacturer’s official data sheet. |
| Applied Medical | Inzii™ Retrieval System | Own range | Pending confirmation | System with opening guide; verify codes, dimensions and material in the manufacturer’s official datasheet. |
5. Selection tips and variants of interest
Select the bag capacity according to the expected specimen volume: for very small samples (tumours, lymph nodes, biopsy pieces, small excisions), this 35 ml version with 40 mm mouth diameter is the most suitable; for small and medium-sized samples, the 80 ml (WZSRB-A-60); for moderate procedures, the 250 ml (WZSRB-B-80) or 350 ml (WZSRB-B-100); and for bulky extractions —large fibroids, spleens, kidneys or extensive surgical specimens—, the 1000 ml version (WZSRB-B-130), the largest capacity in the range. Always verify the compatibility of the deployment diameter with the working channel of the trocar of your laparoscopic tower (usual market use: 10–12 mm trocars; confirm deployment before the procedure). As it is a single-use device, calculate stock according to the volume of procedures and consider the family variants to cover the entire range of surgeries of the general surgery, gynaecology and digestive system department. For volume purchase conditions or hospital budgets, consult your technical-commercial advisor at Cahnos.










Reviews
There are no reviews yet.