Description
Percutaneous dilatation kit, Griggs technique, with 9 mm cannula and fixed flange
This percutaneous dilatation kit using the Griggs technique is the single-use solution for establishing a safe airway quickly, minimally invasively and in a controlled manner in adult patients. It includes a standard 9 mm tracheostomy cannula with fixed flange, offering stable and predictable fixation, together with all the necessary access instruments for tracheostomy, cricothyrotomy, coniotomy or laryngotomy. Designed for intensive care, emergency and anaesthesia teams that need a reproducible, sterile and complete procedure in a single package.
Technical explanation of the device and procedure
Percutaneous dilatational tracheostomy (PDT) using the Griggs technique is an evolution of the Ciaglia technique: it is performed at the bedside, under bronchoscopic control, without the need to transfer the patient to the operating theatre. The procedure begins with tracheal puncture using the 16 G introducer needle, continues with the passage of the J-tip guide wire (a feature that minimises tissue trauma), and ends with progressive dilatation of the opening using the 14 Fr dilator and advancement of the pre-mounted cannula over the introducer with locking system, which maintains position during insertion and prevents steps between the introducer and the cannula tip. This kit is supplied without dilatation forceps, so the sequence relies on single-dilator dilatation, ideal for services that opt for this variant of the technique.
The cannula incorporates a low-pressure cuff, universal 15 mm connector, radiopaque line for radiological control and a fixed, flexible cervical flange in transparent plastic that allows proper visualisation of the stoma. All components are single-use, latex-free and phthalate-free.
Technical specifications and kit contents
Kit contents TP02-79
| Component | Characteristic |
|---|---|
| Standard 9 mm tracheostomy cannula | Fixed flange, low-pressure cuff, 15 mm connector, radiopaque line |
| Tracheostomy tube introducer | Locking system and conical tip for safe insertion |
| Dilator | 14 Fr for progressive dilatation of the stoma |
| Guidewire | J-tip 0.05 inches, kink-resistant NiTiNol core |
| Safety scalpel No. 15 | With retractable protection and fixed blade |
| Syringe | 10 ml |
| Introducer needle | 16 G |
| Fixation band | Skin colour with Velcro-type closure |
| Instrument table cover | Sterile field cover |
| Tracheal compress | 9 x 9 cm, three-layer foam |
| Gauze swabs | 10 x 10 cm |
| Sterile lubricating gel | Individual sachet |
Technical data
| Parameter | Specification |
|---|---|
| Technique | Percutaneous dilatational tracheostomy, Griggs technique |
| Tube diameter | 9 mm (standard); exact outer diameter and length according to the tube’s technical data sheet |
| Flange type | Fixed, cervical, flexible, transparent plastic |
| Cuff | Low pressure |
| Dilatation forceps | Not included (kit without forceps) |
| Use | Single-use (disposable) |
| Sterilisation | Ethylene oxide (ETO), process validated per EN 11135-1; desorption per ISO 10993-7 |
| Presentation | Sterile, individually packaged |
| Latex / phthalates | Latex-free and phthalate-free in all components |
| Regulatory classification | CE Class IIa medical device (Directive 93/42/EEC) |
Equivalences and cross-references
SKU TP02-79 corresponds to Cahnos’s own reference within the family of percutaneous tracheostomy kits (manufactured by Deaflux). As a direct range equivalent, this kit shares the exact configuration (standard fixed flange, without forceps) with references TP02-77 (7 mm) and TP02-78 (8 mm), which differ only in cannula diameter and are therefore not interchangeable 1:1 depending on the patient.
At category level, the set is comparable to percutaneous dilatation kits from other manufacturers, such as the TRACOE experc kit (REF 520 from TRACOE), based on the Ciaglia-type dilatation technique with single dilator, Seldinger wire and guide catheter. This comparison is functional and categorical: component configuration, diameter and cannula geometry may differ, so it should not be considered an exact equivalence between brands. There is no manufacturer-validated equivalence table between brands; consult Cahnos’s technical department before using this reference in tenders or purchasing protocols.
Selection tips and variants of interest
The cannula diameter should be chosen according to the patient’s anatomy and ventilation requirements: 7 mm for small-built adults, 8 mm as the usual standard calibre and 9 mm (this kit) for patients with a wide airway or requiring greater ventilatory flow. The fixed flange provides stable fixation and simplifies placement; if the patient’s cervical anatomy is variable, consider the adjustable flange variant. If the service prefers to complete dilatation with forceps under endoscopic control, the version with dilatation forceps should be chosen instead of this kit. For patients with abundant secretions or need for subglottic suction, there is a variant with subglottic suction lumen. Before use, verify the integrity of the sterile packaging and the expiry date.
References from the same family at Cahnos
| SKU | Diameter | Flange | Forceps |
|---|---|---|---|
| TP02-77 | 7 mm | Standard fixed | Without forceps |
| TP02-78 | 8 mm | Standard fixed | Without forceps |
| TP02-79 | 9 mm | Standard fixed | Without forceps (this kit) |
| TP02-69 | 9 mm | Standard fixed | With forceps |
| TP02-29 | 9 mm | Adjustable | Without forceps |
| TP02-76 | 9 mm | Fixed with suction | Without forceps |





Reviews