Description
Percutaneous dilatation kit, Griggs technique, with adjustable flange
This percutaneous dilatation kit based on the Griggs technique is the comprehensive single-use solution for establishing a secure airway quickly, minimally invasively and in a controlled manner in adult patients. It includes a standard 9 mm tracheostomy cannula with adjustable cervical flange, which allows the tube fixation to be adapted to each anatomy, together with all the access instrumentation required for tracheostomy, cricothyrotomy, coniotomy or laryngotomy.
This kit is supplied without dilatation forceps: the sequence relies on the single 14 Fr dilator, the ideal variant for departments that prefer not to use forceps under endoscopic control. A single order, a single code and the assurance that the team has all the instrumentation with full traceability, reducing preparation time and facilitating standardisation of the procedure in ICU, emergency, anaesthesia and airway units.
Technical explanation of the device and procedure
Percutaneous dilatational tracheotomy (PDT) according to the Griggs technique is an evolution of the Ciaglia technique: it is performed at the bedside, usually under bronchoscopic control, without the need to transfer the critically ill patient to the operating theatre. The procedure begins with tracheal puncture using the 16 G introducer needle, continues with the passage of the J-tip guidewire (atraumatic tip that minimises tissue damage) and ends with progressive dilatation of the opening using the 14 Fr dilator and advancement of the pre-mounted cannula over the introducer with locking system and conical tip, which maintains the tube position during insertion and avoids steps between the introducer and the end of the cannula.
The cannula incorporates a low-pressure cuff, a universal 15 mm connector compatible with the ventilator circuit, a radiopaque line for radiological control and an adjustable cervical flange in transparent plastic that allows the fixation to be adapted to each patient and maintains correct visualisation of the stoma. All components are single-use, latex-free and phthalate-free.
Technical specifications and kit contents
Contents of kit TP02-29
| Component | Characteristic |
|---|---|
| Standard 9 mm tracheostomy cannula | Adjustable flange, low-pressure cuff, 15 mm connector, radiopaque line |
| Tracheostomy tube introducer | Locking system and conical tip for safe insertion |
| Dilator | 14 Fr for progressive dilatation of the stoma |
| Guidewire | J-tip of 0.05 inches, NiTiNol core resistant to kinking |
| Guide catheter | For control and precision in tube positioning |
| Safety scalpel No. 15 | With retractable protection and fixed blade |
| Syringe | 10 ml |
| Introducer needle | 16 G |
| Fixation band | Skin colour, with Velcro-type closure |
| Instrument table cover | Sterile field cover |
| Tracheal compress | 9 x 9 cm, three-layer foam |
| Gauze swabs | 10 x 10 cm |
| Sterile lubricating gel | Individual sachet |
| Dilatation forceps | Not included (kit without forceps) |
Technical data
| Parameter | Specification |
|---|---|
| Technique | Percutaneous dilatational tracheostomy, Griggs technique |
| Tube diameter | 9 mm (standard); exact outer diameter and length according to the tube’s technical data sheet |
| Tube type | Standard |
| Flange type | Adjustable, cervical, flexible, transparent plastic |
| Balloon (cuff) | Low pressure |
| Connector | Universal 15 mm (15M) |
| Radiological control | Radiopaque line |
| Dilatation forceps | Not included (dilatation with single dilator) |
| Use | Single-use (disposable) |
| Sterilisation | Ethylene oxide (ETO), process validated per EN 11135-1; desorption per ISO 10993-7 |
| Presentation | Sterile, individually packaged |
| Materials | Latex-free and phthalate-free in all components |
| Regulatory classification | CE Class IIa medical device (Directive 93/42/EEC) |
| Indications | Percutaneous tracheostomy, cricothyrotomy, coniotomy or laryngotomy |
| Scope of use | ICU, emergency, anaesthesia and airway units |
Equivalences and cross-references
The SKU TP02-29 corresponds to a Cahnos own reference within the family of percutaneous tracheotomy kits (manufactured by Deaflux). As a direct range equivalence, references TP02-27 (7 mm) and TP02-28 (8 mm) share the exact configuration (standard tube, adjustable flange, without forceps) and only differ in the cannula diameter: they are not 1:1 interchangeable depending on the patient.
At category level, the set is comparable to percutaneous dilatational tracheostomy systems from other manufacturers, such as the TRACOE experc kit (REF 520 from TRACOE/Atos Medical), based on the Ciaglia-type dilatation technique with single dilator, Seldinger wire and guide catheter; the percutaneous sets from Cook Medical (Ciaglia and Melker families); and the Griggs technique kits from Portex/ICU Medical (series 100/893 without forceps and 100/891 with forceps). This comparison is functional and categorical: the component configuration, diameter, material and geometry of the cannula may differ, so it should not be considered an exact equivalence between brands. There is no manufacturer-validated equivalence table between brands; consult the technical department of Cahnos before using this reference in tenders or purchasing protocols.
References from the same family at Cahnos
| SKU | Diameter | Tubing | Flange | Forceps |
|---|---|---|---|---|
| TP02-27 | 7 mm | Standard | Adjustable | Without forceps |
| TP02-28 | 8 mm | Standard | Adjustable | Without forceps |
| TP02-29 | 9 mm | Standard | Adjustable | Without forceps (this kit) |
| TP02-07 | 7 mm | Standard | Adjustable | With forceps |
| TP02-08 | 8 mm | Standard | Adjustable | With forceps |
| TP02-09 | 9 mm | Standard | Adjustable | With forceps |
| TP02-37 | 7 mm | Reinforced | Adjustable | Without forceps |
| TP02-38 | 8 mm | Reinforced | Adjustable | Without forceps |
| TP02-39 | 9 mm | Reinforced | Adjustable | Without forceps |
| TP02-77 | 7 mm | Standard | Standard fixed | Without forceps |
| TP02-78 | 8 mm | Standard | Standard fixed | Without forceps |
| TP02-79 | 9 mm | Standard | Standard fixed | Without forceps |
Selection tips and variants of interest
The cannula diameter should be chosen according to the patient’s anatomy and ventilation requirements: 7 mm for adults of small build (TP02-27), 8 mm as the usual standard calibre (TP02-28) and 9 mm (this kit) for patients with a wide airway or who require greater ventilatory flow.
The adjustable flange provides a relevant clinical advantage in patients with cervical oedema or variations in neck thickness, as it allows the tube fixation to be adapted; if a fixed and predictable fixation is preferred, consider the fixed flange series (TP02-79). If the department applies the complete Griggs sequence with forceps under endoscopic control, the version with dilatation forceps (TP02-09) should be chosen; if maximum structural resistance of the tube against kinking is required, the series reinforced with helical winding (TP02-39). For patients with abundant secretions or prolonged mechanical ventilation, consider the variant with subglottic suction lumen (TP02-76, fixed flange). Before use, verify the integrity of the sterile packaging and the expiry date; the kit is single-use and must be disposed of as healthcare waste according to current local regulations.






Reviews