Description
1. Introduction
The Nasopharyngeal Oropharyngeal Cannula Size 5 (Ref. NC5011501) is an essential medical device for airway management in clinical settings. It is designed to separate the tongue from the posterior pharyngeal wall and maintain respiratory patency in patients with loss of muscle tone, who are unconscious or under general anaesthesia. It is supplied in a box of 10 sterile units, with individual packaging that ensures immediate use and prevents cross-contamination. It is the reliable and quick-to-place option that hospitals, clinics, emergency services and patient transport centres need for their airway trolley.
2. Technical explanation of the device
The oropharyngeal cannula (Guedel type) works by preventing the tongue and soft tissues from collapsing against the posterior pharyngeal wall, ensuring a continuous and stable airflow during ventilation with a self-inflating bag, anaesthetic induction or cardiopulmonary resuscitation. Its anatomical curved design reproduces the morphology of the palate and pharynx, and its central channel facilitates oxygenation and suction of secretions. The bite block prevents occlusion of the airway and allows size identification by colour coding according to the ISO 5364 standard. It is a sterile, single-use product, which prevents cross-contamination between patients. Size 5 (5 cm length) is an initial step in the adult range, indicated for older children, small-build adolescents and reduced oropharyngeal anatomies.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference | NC5011501 |
| Size | 5 (5 cm) |
| Type | Nasopharyngeal / Oropharyngeal (Guedel type) |
| Presentation | Sterile, box of 10 units with individual packaging |
| Units per box | 10 |
| Type of use | Single-use (disposable) |
| Sterility | Yes, individual packaging |
| Material | Medical-grade plastic (not specified on the data sheet; consult the technical department) |
| Application | Anaesthesia, emergency, ICU, resuscitation and patient transport |
| Function | Maintains a patent oropharyngeal airway and prevents obstruction by the tongue |
| Size identification | Colour coding of the bite block (ISO 5364 standard; the exact code may vary by manufacturer and European/American standard) |
This reference is part of Cahnos’s range of sterile oropharyngeal cannulas, available in progressive sizes:
| Reference | Size | Presentation |
|---|---|---|
| NC5011501 | 5 (5 cm) | Box of 10 units, sterile |
| NC6013001 | 6 (6 cm) | Box of 10 units, sterile |
| NC7015001 | 7 (7 cm) | Box of 10 units, sterile |
| NC8017001 | 8 (8 cm) | Box of 10 units, sterile |
| NC9019001 | 9 (9 cm) | Box of 10 units, sterile |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer for reference NC5011501; it is a Cahnos-specific code. Before using this reference in tenders or direct substitution, consult our technical department.
In terms of functional category comparison (not 1:1 interchangeable), size 5 (5 cm) corresponds to the length coding in centimetres used by most manufacturers of Guedel cannulas. In the Cahnos catalogue, the same size is available in the single-unit range (Ref. 830002M, Guedel ISO5); they differ in manufacturer, rigidity, colour and format, so they should be assessed according to protocol. The high-consumption sterile range in boxes of 50 units (Refs. 5000 to 5004) covers sizes 6 to 10 cm, so for size 5 this presentation in a box of 10 units is recommended. The adjacent sizes of the same family (Refs. NC6013001 and NC7015001) complete the airway trolley stock.
Sizing note: according to the European standard, sizes correspond to a larger measurement than the American standard, so the length in centimetres and colour coding should always be verified with the manufacturer’s data sheet before substituting a reference.
5. Selection tips and variants of interest
To choose the correct oropharyngeal cannula size, measure the distance between the corner of the mouth and the angle of the patient’s mandible: the cannula length should approximate this distance without exceeding it. As a reference, size 5 (5 cm) fits older children, small-build adolescents and reduced oropharyngeal anatomies; larger patients will require sizes 6 to 9 (Refs. NC6013001, NC7015001, NC8017001 and NC9019001). It is recommended to lubricate the cannula before insertion and place it with a 180-degree rotation to minimise trauma; the device should only be used in unconscious patients or those with depressed level of consciousness. For high-consumption programmes, consider the sterile presentation in a box of 50 units (Guedel range) as a more economical alternative. Consult our technical-commercial team for volumes, supply conditions and configuration of airway kits adapted to your service.




Reviews